My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1018 14TH ST 2023-02-09
>
Address Records
>
14TH ST
>
1018
>
1018 14TH ST 2023-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2023 1:07:39 PM
Creation date
5/17/2017 10:00:14 AM
Metadata
Fields
Template:
Address Document
Street Name
14TH ST
Street Number
1018
Notes
BULKHEAD PLATFORM GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
223
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHANNON 6WILSON,INC. <br /> If the location of the bulkhead is moved, different water levels are assumed, steeper <br /> slopes are used, or multiple anchor levels are considered, and the lateral earth pressures shown in <br /> Figures 5 and 6 would not be applicable and should be revised. As discussed in Section 4.1.1, <br /> liquefaction potential in the Segment D area is predicted to be higher, based on boring B-1 B. <br /> Therefore, if a similar bulkhead design is desired for Segment D, we recommend performing <br /> additional explorations and laboratory testing to evaluate the liquefaction potential of the fill and <br /> alluvial soils in this area. if the additional borings indicate minimal and localized liquefaction <br /> under the 200-year.design ground motion, then the earth pressures shown in Figure 6 would be <br /> applicable. <br /> The passive earth pressure diagrams shown in the figures are based on ultimate values. <br /> To obtain allowable values, we recommend that the passive earth pressure values be divided by <br /> 1.5 for static conditions or 1.0 for seismic conditions. Alternatively,the ultimate passive earth <br /> pressures can be adjusted based on allowable displacement by using mobilization factors <br /> provided in Figure 7. <br /> 4.2.2 Deadman <br /> A single row of deadman anchors is proposed as part of the bulkhead design. <br /> Recommended lateral earth pressures for the design of the deadman anchors are provided in <br /> Figure 8. Lateral earth pressures will depend on the type of soil that is present in front of the <br /> deadman anchor. If the deadman anchor is constructed in a shored excavation that is not bigger <br /> than the anchor,then the anchor would react against in situ soil, which is uncompacted fill and <br /> alluvial soil. To improve the resistance of the deadman anchor, the in situ soil in front of the <br /> anchor could be removed and replaced with compacted structural fill. The required dimensions <br /> of this replacement are shown in Figure 8. The passive resistance values shown in the figure are <br /> ultimate values. To obtain allowable values, we recommend that the passive earth pressure <br /> values be divided by 1.5 for static conditions or 1.0 for seismic conditions. Alternatively, the <br /> Ultimate passive earth pressure can be adjusted based on allowable displacement by using <br /> mobilization factors provided in Figure 7, as discussed above. <br /> 4.3 Evaluation of Temporary Dredged Condition <br /> Temporary dredging is planned along areas of the existing bulkhead to remove contaminated <br /> sediments. The 90 percent design drawings by Landau indicate that the extent of dredging <br /> varies, and that it will be performed concurrently with the construction of the new bulkheads. At <br /> Segments A and B soil will be dredge to elevation -14 feet with no slope in front of the bulkhead. <br /> 21-1-21761-003-R I f.doca/wp/cIp 21-1-21761-003 <br /> 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.