My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1018 14TH ST 2023-02-09
>
Address Records
>
14TH ST
>
1018
>
1018 14TH ST 2023-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2023 1:07:39 PM
Creation date
5/17/2017 10:00:14 AM
Metadata
Fields
Template:
Address Document
Street Name
14TH ST
Street Number
1018
Notes
BULKHEAD PLATFORM GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
223
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Alignment A q <br /> (surcharge) <br /> Assumed Ground Surface H-300 Y=110 pcf <br /> If <br /> Elev.17.5 Feet - - - <br /> Elev.11 Feet <br /> Assumed High Water <br /> Very loose to medium dense, Level Behind Wall <br /> Ignore Upper 3 Feet graylbrom,slightly silly,fine <br /> Assumed Mean Low Water 9 PP <br /> - to medium SAND,scattered Y=110pcf <br /> Elev.0 Feet -_. Z_ organics and debris(Hf,Ha) 580 .� + y'=46 pcf <br /> (Potentially Liquefiable) 28° <br /> Slope Inclination Vanes,See Table 1 T (Seismic <br /> Case Only) <br /> Assumed Mud Line 780 <br /> 40C, <br /> Elev.-12 Feet -- - --- - -- - <br /> 2750 - 570 0.4q � 125 pcf <br /> Dense to very dense. + y= <br /> gray,silly fine SAND STATIC y'=61 pcf <br /> 8010 - (Ha.He) - 760 SURCHARGE �'=36° <br /> PRESSURE <br /> Elev.-25 Feet - - _. -. _- T _. - � 75 <br /> 10100 - 630 <br /> SEISMIC <br /> Very dense. INCREMENT <br /> gray,slightly y=130 pcf <br /> D silty,fine to <br /> medium SAND NOTE: 66 pcf <br /> y'= <br /> (OPn� A horizontal seismic 0'=40° <br /> coefficient of 0.12 times <br /> gravity was used to <br /> develop the seismic <br /> surcharge for a 200-year <br /> seismic event. <br /> 10100+550D 630+13D—+{ 130►{ <br /> ULTIMATE PASSIVE SOIL ACTIVE UNBALANCED ASSUMED <br /> EARTH PRESSURE DESCRIPTIONS EARTH PRESSURE WATER PRESSURE SOIL <br /> (See Note 8) PARAMETERS <br /> NOTES Not to Scale <br /> 1. These lateral earth pressures shown are for the case of a new sheet pile bulkhead constructed behind the existing bulkhead. <br /> Table 1.See Note 5 <br /> 2. All pressures are in units of pounds per square foot(psf).Components of the pressure behind the wall should be added to <br /> get the total pressure on the wall for each loading case. Slope C,Value <br /> 3. Active and passive earth pressures are shown per unit width for sheet pile walls. Active lateral earth pressures should be 2H:1 V 11 <br /> used for flexible wall systems that are able to displace at least 0.001 times the height of the wall. If the wall does not <br /> displace at least 0.001 times the height.the earth pressures should be reevaluated. LEGEND 3H:1 V 19 <br /> 4. Earth pressures are based on either a cantilevered wall system or single anchor wall system. - <br /> Assumed or Measured Water Level 4H:1V 24 <br /> a <br /> 5. Select coefficient(C,)based on the slope in front of the retaining wall. D Depth of Penetration in Feet Below Elevation <br /> - 14th St&16th St-Marina District <br /> LL 6. The assumed soil profile is generalized from the soils described on current and previous boring logs.Variations between the Square Foot Port of Everett Surcharge Pressure in Pounds Per S <br /> 4 profile and actual subsurface conditions may exist. q g q <br /> Everett,Washington <br /> 7. Earth pressures are based on the dimensions and elevations shown.If different elevations(such as elevation of top of the y Effective Unit Weight <br /> mudline slope in front of the wall)are used for design,the earth pressures shown on this figure would not be applicable.and RECOMMENDED <br /> h should be revised based on the final configuration of the bulkhead and adjacent slope. y Total Unit Weight LATERAL EARTH PRESSURES <br /> 9 8. The provided passive earth pressures are ultimate values. For allowable,these values should be reduced by a factor of <br /> safety of 1.5 for static case and a factor of safety of 1.0 for seismic cases. Alternatively.the passive earth pressures can be �' Effective Friction Angle FOR SEGMENTS A,B,AND C <br /> h reduced by a mobilization factor as described on Figure 8. January 2014 21-1-21761-003 <br /> V545 Westi <br /> emated the seismic increment using the Mononobe-Okabe Method for a 200-year seismic event with a horizontal 545 Active Earth Pressure(See Note 2) <br /> seismic coefficient of 0.12 gravity,about half the peak ground acceleration. SHANNON bWILSON,INC. FIG.5 <br />