Laserfiche WebLink
Centedine Alignment B <br /> q(surcharge) ExistingWall <br /> Assumed Ground Surface <br /> Elev.17.5 Feet - - - - -- ✓ 280- <br /> I <br /> y=125 pcf <br /> J1 y'=125 pcf <br /> New FII Assumed High Water Qr'=34° <br /> i Existing Fill � Level Behind Wall <br /> � <br /> Assumed Mean Low Water Ignore Upper 3 Feet --- 490 - <br /> Elev.0 Feet z - - Elev.2 Feet <br /> - Very loose to medium dense, l I 620 <br /> Slope Inclination Varies.See Table 1 gray/brown,slightly silty,fine y,-4fi pcf <br /> p to medium SAND,scattered (Seismic y= P <br /> organics and debris(Hf,Ha) <br /> Case Only) b'=28° <br /> Assumed Mud Line 830 <br /> 40Ct- - (Potentially Liquefiable) <br /> Elev.-12 Feet -- - <br /> 2750 H 0.4q <br /> L801 <br /> Dense to very dense, 610 1 p,;r <br /> T � i25gray,silty fine SAND STATIC -,1 pit <br /> 0- - (Ha,He) SURCHARGE -3g <br /> - - 800 PRESSURE <br /> Elev.-25 Feet t -- -- - - -- <br /> 70 � <br /> 10100 660 <br /> SEISMIC <br /> Very dense, INCREMENT <br /> gray,slightly .=130 pcf <br /> D silty,fine to <br /> medium SAND NOTE: 66 pcf <br /> = <br /> (Opnfl A horizontal seismic (i=40° <br /> coefficient of 0.12 times <br /> gravity was used to <br /> develop the seismic <br /> surcharge. <br /> I <br /> - 10100+550D -- 660+13D 130 Ji <br /> ULTIMATE PASSIVE ASSUMED <br /> SOIL ACTIVE UNBALANCED <br /> EARTH PRESSURE SOIL <br /> DESCRIPTIONS EARTH PRESSURE WATER PRESSURE <br /> z NOTES (See Note 8) PARAMETERS <br /> 1. These lateral earth pressures shown are for the case of a new sheet pile bulkhead constructed in front of the existing bulkhead and <br /> backfilled with compacted structural fill. Not to Scale <br /> a 2. All pressures are in units of pounds per square foot(psf). Components of the pressure behind the wall should be added to get the total <br /> pressure on the wall for each loading case. <br /> Table 1,See Note 5 <br /> 3. Active and passive earth pressures are shown per unit width for sheet pile walls. Active lateral earth pressures should be used for flexible <br /> wall systems that are able to displace at least 0.001 times the height of the wall. If the wall does not displace at least 0.001 times the Slope Ct Value <br /> height,the earth pressures should be reevaluated. <br /> 2H:1V 11 <br /> 4. Earth pressures are based on either a cantilevered wall system or single anchor wall system. <br /> LEGEND 3H:1V 19 <br /> 5. Select coefficient(Cr)based on the slope in front of the retaining wall. Assumed or Measured Water Level 4H:1 V 24 <br /> 6. The assumed soil profile is generalized from the soils described on current and previous boring logs.Variations between the profile and <br /> actual subsurface conditions may exist. D Depth of Penetration in Feet Below Elevation <br /> LL 7. Earth pressures are based on the dimensions and elevations shown. If different elevations(such as elevation of top of the mudline slope 14th St 8 16th St-Marina District <br /> 4 in front of the wall)are used for design,the earth pressures shown on this figure would not be applicable,and should be revised based on q Surcharge Pressure in Pounds Per Square Foot Port of Everett <br /> the final configuration of the bulkhead and adjacent slope. Everett.Washington <br /> 8 The provided passive earth pressures are ultimate values. For allowable,these values should be reduced by a factor of safety of 1.5 for Y Effective Unit Weight <br /> 7 static case and a factor of safety of 1.0 for seismic cases. Alternatively,the passive earth pressures can be reduced by a mobilizationy Total Unit Weight RECOMMENDED LATERAL EARTH <br /> $ factor as described on Figure 8. PRESSURES FOR SEGMENT D <br /> 9. We estimated the seismic increment using the Mononobe-Okabe Method for a 200-year seismic event with a horizontal seismic coefficient Effective Friction Angle <br /> of 0.12 gravity,about half the peak ground acceleration. - January 2014 21-1-21761-003 <br /> 10. The earth pressures shown above do not consider potential for liquefaction behind the wall. For Segment D.additional exploration and 545 Active Earth Pressure <br /> I. testing should be performed to evaluate the liquefaction potential and associated earth pressures in Segment D. SHANNON&WILSON,INC. <br /> SFIG.6 <br />