ss <br /> `14 <br /> Modifications included incorporating the use of variable frequency drives(VFD's)to operate <br /> the pumps instead of soft starts and site piping modifications to be compatible with the <br /> Emergency Force Main Replacement project. <br /> The most significant of these modifications is the use of VFD's,which impacted the majority <br /> of the electrical drawings and certain specification sections. With the use of VFD's the <br /> pump drive shaft system was no longer a practical approach and alternative close-coupled <br /> pump systems needed to be considered. With the elimination of the drive shafts,this also <br /> impacted the layout and access in the drywell, overhead crane system and certain structural <br /> elements. <br /> With the modifications being significant,the City decided to postpone the bid opening <br /> approximately four weeks and issue an addendum that reflected the changes to the contract <br /> documents. Elements of this subtask include: <br /> • Coordination with City staff on VFD preferences and manufacturers, as well as layout <br /> of station and site. • <br /> • Evaluate alternatives for building layout with VFD's and select preferred alternative. <br /> • Review and provide information on close-coupled pump alternatives. <br /> • Consider access and drywell modifications,including overhead crane system. <br /> • Evaluate site piping modifications to be compatible with the Emergency Force Main • <br /> Replacement Project. • <br /> • Review alternatives with City and define preferred alternatives for lift station <br /> modifications. <br /> • Modify electrical drawings to represent the use of VFD's and immersible motors. <br /> • Revise building layout to be compatible with VFD installation, close-coupled pumps <br /> with immersible motors,pump access and oyerhead crane system. <br /> • Provide overhead crane system in drywell,modify crane in control room. <br /> • Modify structural design accordingly,removing drive shaft access and support <br /> systems. <br /> .• Modify civil drawings to accommodate modification to the site piping. <br /> • Provide additions to the specifications as necessary to reflect modifications. • <br /> •. Prepare an addendum to reflect modifications as define within this subtask. <br /> • Submit draft addendum for City review and receive comments. • <br /> • Prepare addendum to be issued to plan holders. <br /> • Provide updated cost estimate to the City that reflects modified project scope. <br /> Task 9—Unanticipated Services • <br /> I. Additional Surveying—At the request of the City,additional surveying services were <br /> provided to map the extent of critical areas at the site based on flagging provided by the <br /> City's environmental subconsultant,AMEC. Services included: <br /> • Site survey to locate flagging <br /> City of Everett MURRAY,SMITH&ASSOCIATES,INC. LS 24 WO#UP 3313 <br /> July 2012 Engineers/Planners Page 5 <br /> S:\DVoigt\Sewer Lift Sta 24_MSA_UP3313\Council and Bdgt Com\Amend 5\Scope of Work 8-1O12.doc <br /> 127 <br />
The URL can be used to link to this page
Your browser does not support the video tag.