Laserfiche WebLink
• Response to Structural Comments <br /> Permit:B1401-024 <br /> 1804 Hewitt Avenue <br /> Detail 2/A1.1 addresses 1 hour fire and STC 50 requirements for the <br /> floor/ceiling assembly. We used an approximate assembly to arrive at our STC <br /> and IIC rating (attached). <br /> 6. The plans should show the locations of smoke detectors. The smoke detectors <br /> should be hard-wired, with battery back-up and interconnected within each <br /> dwelling unit. IFC Section 1103.8 <br /> Smoke detectors are noted at each room and hallway of each unit. <br /> 7. The plans should show the locations of the carbon monoxide detector within <br /> each unit. IFC Section 1103.9 <br /> Carbon monoxide detectors are noted at each room and hallway of each unit. <br /> 8. Each toilet room that does not have an operable window to the exterior should <br /> be shown with a minimum 50 cfm mechanical exhaust fan. The fan should not <br /> penetrate fire-resistive ceiling without required ceiling radiation dampers, <br /> shafts or alternate approvals. IPMC Section 403.2 <br /> Mechanical fans are noted at internal bathrooms without exterior windows. <br /> 9. Each kitchen that does not have an operable window to the exterior should be <br /> shown with a minimum 100 cfm mechanical exhaust fan. The fan should not <br /> penetrate fire-resistive ceiling without required ceiling radiation dampers, <br /> shafts or alternate approvals. IPMC Section 403.1 and 403.3 <br /> Mechanical fans are noted at internal kitchens without exterior windows. <br /> 10. Exposed stud cavities separating conditioned space from non-conditioned <br /> space should be filled with insulation. The R-value of the insulation should be <br /> shown on the plans (Minimum of R-3.0 per inch). WSEC Section C101.4.3 <br /> Insulation is called for at conditioned/non-conditioned walls, the required R- <br /> values are noted on each plan sheet in the plan notes. <br /> Please call, (206) 380-0732, if you have questions. <br /> Sincerely, <br /> Sliderule Engineering Works, Ilc <br /> jr . Herrick, P.E. <br /> 227 V street southeast,auburn,washington 98002-5518 t=206+380+0732,e-mail=alhpe_sliderule@q.com <br /> aj <br />