R L Alia Company 5/4/2017
>
Contracts
>
Capital Contract
>
R L Alia Company 5/4/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2018 10:23:48 AM
Creation date
5/25/2017 9:59:28 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
R L Alia Company
Approval Date
5/4/2017
Council Approval Date
3/29/2017
Department
Public Works
Department Project Manager
David Voigt
Subject / Project Title
Hayes Street Regulator and CSO Controls
Public Works WO Number
UP3398
Tracking Number
0000647
Total Compensation
$3,034,395.00
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
R L Alia Company 11/28/2017 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
416
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> the concrete with epoxy resin. Dams shall be placed at the front of the holes to confine <br /> the epoxy and shall not be removed until the epoxy has cured in the hole. <br /> 6-02.3(28) Precast Concrete Panels <br /> Section 6-02.3(28)is supplement with the following: <br /> Contractor Designed Reinforced Concrete Vaults <br /> The following vaults shall be designed by the Contractor and may be precast: <br /> 1. SRO1 Regulator Structure <br /> 2. SRO2 Regulator Structure <br /> 3. Trunk C Flow Screening Structure, and <br /> 4. Lift Station No.9 Flow Screening Structure. <br /> All appurtenances such as manhole access lids and internal walls, weirs, plates, and ladders <br /> shall be included in the design. <br /> The vaults may be comprised of individual pieces connected at the site to create the vault <br /> geometry as shown in the Plans. If the vault walls are cast as individual walls, each wall shall <br /> be comprised of a single monolithic piece which is then connected to other walls and slabs as <br /> required in the Plans and these Specifications. Base slabs and roof slabs may be comprised of <br /> separate pieces connected to one another with a grouted shear key as detailed in the Plans. <br /> Provide watertight connections between all precast elements. Connections shall consist of a <br /> grouted keyway with two rows of watertight gaskets along each wall/slab and wall/wall. <br /> Provide bolted connections between each wall corner consisting of a 1" diameter bolt and <br /> threaded inserts at 2 feet maximum spacing. Bolted connection shall be recessed and filled with <br /> grout flush with face of wall. <br /> . <br /> - - _ -. 4 !!! z• <br /> • ! <br /> bent or welded reinforcing bars shall be ASTM A706. <br /> The vaults shall be constructed according to ASTM C1577-16. The vaults shall be reinforced <br /> concrete using concrete and steel reinforcing bars as specified in the Plans.[M°area rnaae°aumKu] <br /> The Contractor shall confirm the location of the blockouts in the vault slab with the screening <br /> equipment manufacturer for the screening equipment lift and discharge chute prior to <br /> preparation of vault shop drawings. Coordinate and confirm debris receptacle placement and <br /> fasteners with the screening equipment manufacturer prior to preparation of shop drawings. <br /> the AASHTO LRFD Bridge-Design Specifications(LRFD). <br /> The Contractor shall submit Type 2E working drawings per Section 1-05.3 to the Engineer for <br /> review prior to fabrication. The vaults shall be designed in accordance with the American <br /> Concrete Institute (ACI) Code Requirements for Environmental Engineering Concrete <br /> Structures(ACI 350-06)for normal environmental exposure conditions.[M°di,eaper naae°aumi] <br /> Comply with Section 2-09 for submittal and design requirements of required shoring and/or <br /> cofferdams. <br /> Live Load(LL) shall be as shown in the Plans, applied in accordance with the LRFD; <br /> Soil backfill unit weight shall be 125 pcf with an internal friction angle of 32 degrees; <br /> geeteeimieai-r-epeft; <br /> 111 <br /> HAYES STREET REGULATOR February, 2017 <br /> AND CSO CONTROLS (SRO1, SRO2,AND SRO3) <br /> WO No—UP3398-31 SP- 158 <br />