Laserfiche WebLink
SYMBOLS & LEGEND GENERAL PLAN NOTES <br /> • aFAN-DIRECT VENT TO OUTSIDE 1. SEE SHEET A001 FOR ALL GENERAL NOTES AND <br /> F -BATHROOMS/LAUNDRY 50 CFM MIN. REQUIREMENTS. <br /> -KITCHEN 100CFM MIN. 2, ENERGY AND AIR QUALITY INFORMATION SEE DIV.17 D E 5 1 G h BUILD <br /> 41 32'2 12" SHEET A001. <br /> CONTINUOUS WHOLE-HOUSE VENTILATION SHALL <br /> OPERATE CONTINUOUSLY SYSTEMS MUST CONFORM 3. SEE BUILDING ELEVATIONS FOR WANDOW OPERATION SEE <br /> TO I.R.C.M1507.3 8 SIZED PER TABLE 1507.3.3(1) <br /> DIV.8 SHEET A001. <br /> FRESH AIR SUPPLY TO BE INTEGRATED WITH FORCED 218 Main Street <br /> .I 20, AIR SYSTEM PER MI507.3.5 4. SEE TYP.MATERIALS LIST ON SECTION SHEET. <br /> _-- <br /> S. SEE SHEET A001 FOR ALL NOTES AND REQUIREMENTS PMB#702 <br /> CONCERNING MECHANICAL,PLUMBING,AND ELECTRICAL Kirkland, WA 98033 <br /> M 54x52 PORCH (M 88x52D THERMOSTAT @ 50"ABOVE FLOOR <br /> 6'3" WINDOW 300 WINDOW B'6' FLOOR PLAN KEY NOTES 425.985.2633 <br /> 110V SMOKE ALARM PER I.R.C.R314 WITH BATTERY p_1 OCCUPANCY SEPARATION: <br /> ' O BACKUP INTERCONNECTED.USE A COMBINATION APPLY(1)LAYER OF 12"G.W.B TO GARAGE SIDE OF <br /> SMOKE/CARBON MONOXIDE ALARM WHERE NOTED RESIDENCE,ATTIC SPACES,AND ALL BEAMS AND <br /> POSTS SUPPORTING A FLOOR-CEILING ASSEMBLY. <br /> v-2a APPLY 910 LAYER OF 518"TYPE"X"G.W.B.TO <br /> ROOM GARAGE CEILING WHEN UNDER HABITABLE ROOOMS. <br /> P-5 I DUCTS THROUGH WALL OR CEILING COMMON TO <br /> HOUSE SHALL HAVE MINIMUM 26 GUAGE STEEL. <br /> (N)36x46 O I O WINDOW SEE DIV.01002.6.A SHEET A001. <br /> WINDOWN)55x38 p-2 1 3/8"MIN.SELF CLOSING SOLID WOOD CORE, <br /> BED#2 So I LIVING WINDOW HONEYCOMB STEEL OR 20-MINUTE FIRE RATED <br /> 309 301 DOOR. <br /> O DOOR SEE DIV.01002.6.8 SHEET A001. <br /> i PJ STAIR ASSEMBLY NOTES:PER I.R.C.SECTION 311.5 <br /> MECHANICAL,PLUMBING,AND ELECTRICAL SYSTEM FOR UNITS: AND DETAIL 12102. <br /> PER DIV.15 8 16 SEE SHEET A001 A.HEADROOM MIN.6'-8"VIDTH MIN.3'-0". <br /> EXISTING FIREPLACEin B.TREADS 10"MIN.DEPTH AND MIN.WIDTH <br /> OF 36"ABOVE HANDRAIL HEIGHT,RISERS 7 3/4"MAX. <br /> HT.TREAD NOSING TO BE MINIMUM OF 3/4'AND A <br /> I 815 <br /> [FLIR]N O UNO $2 MAXIMUM OF 1 1/4"ON STIARS WITH SOLID RISERS. MaClane Remodel <br /> C.HANDRAIL MIN.34'TO MAX.38"ABOVE 2910 16th St <br /> I TREAD NOSING.HANDRAIL TYPE 1 CIRCULAR TO <br /> CL CL O (N)720 3 A.PROVIDE 6"DIAMETER FRESH AIR INTAKE FROM OUTSIDE TO HAVE 1 12"MIN.TO 2"MAX.CROSS SECTION EverettWA 98201 <br /> ry SD/CSL WINDO RETURN AIR PLENUM AT FURNACE WITH MOTORIZED FLOW DIMENSION AND 1 12"MIN.CLEAR FROM WAL, <br /> ry <br /> 3'1* T 1" - - DAMPERS. RETURN RAIL ENDS.HANDRAILS SHALL BE STRONG <br /> B.PROVIDE THERMAL EXPANSION TANK AT WATER HEATER. ENOUGH TO RESIST A 300 POUND POINT LOAD IN <br /> 6'4 12" 5'8" MIN MIN ' C.STRAP WATER HEATER TO FRAMING TOP AND BOTTOM. ANY DIRECTION PER I.R.C.TABLE R301.5 <br /> g _ _ _ _ _ _ CLR __ _ B D.PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. D.INSTALL FIRE BLOCKING BETWEEEN <br /> t SD _ _ STRINGERS AT THE TOP AND BOTTOM OF EACH RUN <br /> v-5 - PER I.R.C.SECTION R30211 <br /> (N)38x48 - `v I COVER USABLE SPACE UNDER STAIR W/ <br /> WINDOW 1 - KITCHEN `3 © 12'G.W.B.PER I.B.C.SECTION R302.7. <br /> c BED#1 -I-- 302 EXISTING WALL TO REMAIN F.INTERMEDIATE BALUSTIERS SHALL BE <br /> SPACED W/LESS THAN 4"BETWEEN BALUSTERS. <br /> 308 < t. NEW/REPLACEMENT 2x4 STUD WALL G.PROVIDE STAIRWAY ILLUMINATION PER <br /> b ?� v-3 I.R.C.SECTION R303.6.SEE DIV.01002.6 SHEET A001, <br /> SAFETY GLAZINGPER LR.C.,SECTION R308 <br /> OA.WINDOWS WITHIN 18"OF FLOOR <br /> SD \\� t VTOS I B.WINDOWS WITHIN A 24"ARC OF DOORS <br /> CONTRACTOR NOTE: C.WINDOWS AT TUBS AND SHOWERS <br /> CONTRACTOR TO VERIFY ALL D.GLAZING IN DOORS <br /> -- EXISTING FIELD CONDITIONS I WITHIN STAIRWELLS <br /> I AND DIMENSIONS. LESS THAN , <br /> 'HORIZ.FROM THE BOT. <br /> STAIR TREAD NOSING,BATH r &BOT.EDGE OF GLAZING IS <br /> r STAIR c LESS THAN 36"ABV.LANDING/WALKING SURFACE. <br /> vai iv a v'7 307 VTOS �., I (N)3636 ,7i SEE DIV.08800 SHEET A001. <br /> e (N)38x24 -rJ_--� �1 a NAN W p_5 EGRESS WINDOW PER I.R.C.SECTION R310.SEE DIV. <br /> WINDOW I 08600 SHEET A001. <br /> IGNITERS FOR GAS FIRED APPLIANCES IN GARAGE <br /> TO BE 1 B"MIN.ABOVE TOP OF SLAB. <br /> __ I SEE DN.15 SHEET A001. <br /> SH CL p.7 COVER WALLS ADJACENT TO TUBS AND SHOWERS <br /> CL \ I FAMILY n WITH NON-ABSORBENT MATERIAL TO 72'ABOVE <br /> T3 12" 303 "' DRAIN INLETS,PER I.R.C.SECTION 307.2. <br /> (N)36x24 F❑ m SEE DIV.09250 SHEET A001. <br /> WINDOW <br /> VTOS _ I )4&36 P_g (2)LAYERS OF FLOOR SHEATHING OVER FRAMING. <br /> o v MSTR �'�'" I ND W p_g 7 3/4"MAX.RISER WITH 10-MIN.RUN,IF MORE THAN <br /> BATHN (3)RISERS,HANDRAIL REQUIRED PER I.R.C.SECTION <br /> R311.7.4. Job Number 16.009 <br /> 306 SEE DIV.01002.7 SHEET A001. <br /> C File Number 18.009.COt.leyout <br /> 1n I P_10 18'Y24"CRAWL-SPACE ACCESS.INSULATE AND <br /> WEATHERSTRIP. <br /> SEE DIV.01002.1 SHEET A001. <br /> ATTIC SPACE ACCESS W/ HEAD <br /> CLEAR WE <br /> CLEARANCE.INSULATE AND WEATHER STRIP. <br /> e I t I <br /> SEE DIV.01002.2 SHEET A001. <br /> • v-il IC(��wv '_•�\ P-12 FLOOR MATERIAL BREAK UNE <br /> (N6x36 <br /> )3 �� O --- --- J` •r` �+�' P-13 WALL LINE ABOVE <br /> WINDOW <br /> MSTR BED CL DINING o-. ^!' p-u WALL LINE BELOW <br /> 305 304 _ _ _�•`� P-15 FIREPLACE ASSEMBLY NOTES: <br /> A.DIRECT VENT FIREPLACES,INSTALL PER <br /> MFG.SPECIFICATIONS,SHALL CONFORM TO I.R.C. <br /> REQUIREMENTS.SEE DIV.01002.8 SHEET A001. <br /> I -- B.ZERO CLEARANCE FIREPLACES SHALL <br /> CONFORM TO I.R.C.REQUIREMENTS. <br /> G v-2SEE DIV.01002.8 SHEET A001. <br /> a v-5 I C.HEARTH SHALL CONFORM TO I.R.C. <br /> n <br /> .--- - REQUIREMENTS.SEE DIV.01002.8 AND B SHEET A001. 1 Pemdt Submittal 05.09.16 <br /> D.FIREBLOCK OPENINGS AROUND <br /> (FI)30x48 /q\ (N)72.36 PENETRATIONS AT EACH FLOOR PER I.B,C.SECTION <br /> WINDOW 1 WINDOW -XI-4'G N)3BX36 R1003.13. <br /> 4'5" WINDOW <br /> P-16 SEE SITE PLAN FOR EXTENT OF WALKS AND <br /> DRIVEWAYS <br /> 15'4 12' 5'112" 1111 12' p-17 3"DIAMETER STEEL POST <br /> 32'412" P-18 36'GUARDRAIL PER I.R.C.SECTION R312 8 TABLE MAIN FLOOR <br /> R301.5.AT STAIR SLOPES AT 34'ABOVE STAIR <br /> NQSING6. PLAN <br /> P-19 'B'VENT FOR MECHANICAL.1'CLEARANCE ALL SIDES <br /> PER I.R.C.SECTION 1005.3. <br /> i <br /> MAIN FLOOR PLAN SEE DIV.IS SHEET A001. <br /> A1�3 p 2 4 8 N P-20 PLANT SHELF <br /> " " - A103 <br /> P-21 UPPER AND LOWER LINEN CABINETS <br /> P-22 SOFFIT AREA <br /> P-23 INTEGRATED MAKE UP AIR <br /> P-24 2x4 STUDS W/R-21 INSULATION MIN. �� _ <br />