Laserfiche WebLink
SYMBOLS & LEGEND GENERAL PLAN NOTES _ <br /> • • FAN-DIRECT VENT TO OUTSIDE 1. SEE SHEET A001 FOR ALL GENERAL NOTES AND <br /> F -BATHROOMS/LAUNDRY 50 CFM MIN. REQUIREMENTS. dp <br /> KITCHEN 100CFM MIN. 2, ENERGY AND AIR QUALITY INFORMATION SEE DIV.17 ❑E 5 1 C.I, BUILD <br /> SHEET A01. <br /> - CONTINUOUS WHOLE-HOCONTINUOUSLY <br /> SE VENTILATION SHALL 3. SEE BUILDING ELEVATIONS FOR WINDOW OPERATION SEE <br /> A OPERATE CONTINUOUSLY SYSTEMS MUER TABLE ST CONFORM DIV.8 SHEET A001. <br /> 1 FRTO IESH AIR SUPPLY TO BEINTEGRATED iNTH FORCED 218 Main Street <br /> AIR SYSTEM PER MI 507.3.5 4. SEE TYP.MATERIALS LIST ON SECTION SHEET. <br /> 11 5. SEE SHEET A001 FOR ALL NOTES AND REQUIREMENTS PMB#702 <br /> T I CONCERNING MECHANICAL,PLUMBING,AND ELECTRICAL, Kirkland, WA 98033 <br /> CRAWL SPACE THERMOSTAT�50'ABOVEFLOOR FLOOR PLAN KEY NOTES 425.985.2633 <br /> O110V SMOKE ALARM PER I.R.C.R314 WITH BATTERY p_i OCCUPANCY SEPARATION: <br /> BACKUP INTERCONNECTED.USE A COMBINATION APPLY(1)LAYER OF 12"G.W.B TO GARAGE SIDE OF <br /> -- - SMOKE/CARBON MONOXIDE ALARM WHERE NOTED RESIDENCE,ATTIC SPACES,AND ALL BEAMS AND <br /> p-2a a POSTS SUPPORTING A FLOOR-CEILING ASSEMBLY. <br /> '"' a APPLY 910 LAYER OF 5/8"TYPE"X"G.W.B.TO <br /> (N)ACCESS ROOM <br /> DOOR (N)36x DUCTS DI <br /> S THROUGH WALL ORCEILINGCOMMONOTO S <br /> ip-i0 WINDO HOUSE <br /> SHALL <br /> t 6A E IIE 01MINIMUM26GUAGE STEEL. <br /> STOR�iGE O WINDOW <br /> SEE <br /> p_2 1 3/8-MIN.SELF CLOSING 60UD WOOD CORE, <br /> HONEYCOMB STEEL OR 20-MINUTE FIRE RATED <br /> 105 DOOR. <br /> ODOOR SEE DIV.01002.6.8 SHEET A001. <br /> (N)30x48 P-3 STAIR ASSEMBLY NOTES:PER I.R.C.SECTION 311.5 <br /> WINDOW MECHANICAL,PLUMBING,AND ELECTRICAL SYSTEM FOR UNITS: AND DETAIL 121D2. <br /> PER DIV.15 8 16 SEE SHEET A001 A.HEADROOM MIN.6'-8"WIDTH MIN.Y-0". <br /> 21/2. 9'10 12' B.TREADS 10"MIN.DEPTH AND MIN.WIDTH <br /> OF 36"ABOVE HANDRAIL HEIGHT,RISERS 7 3/4"MAX. <br /> EF=O 82 HT.TREAD NOSING TO BE MINIMUM OF 3/4"AND A Maclane Remodel <br /> I <br /> [FUR]N O UNO MAXIM CM HANDRAIL MIN.3470 MAX.38S NTH LABOVE ID RS 2910 16th St <br /> TREAD NOSING.HANDRAIL TYPE 1 CIRCULAR TO <br /> WH FURN MAX BTU A.PROVIDE 6"DIAMETER FRESH AIR INTAKE FROM OUTSIDE TO HAVE 1 12"MIN.TO 2"MAX.CROSS SECTION Everett, WA 98201 <br /> =52,680 RETURN AIR PLENUM AT FURNACE WITH MOTORIZED FLOW DIMENSION AND 1 12"MIN.CLEAR FROM WAL, <br /> `Lv DAMPERS. RETURN RAIL ENDS.HANDRAILS SHALL BE STRONG <br /> EFr, B.PROVIDE THERMAL EXPANSION TANK AT WATER HEATER. ENOUGH TO RESIST A 3D0 POUND POINT LOAD IN <br /> I MECH P6 C.STRAP WATER HEATER TO FRAMING TOP AND BOTTOM. ANY DIRECTION PER I.R.C.TABLE R301.5 <br /> 6 _._. _._._.J._._._._._._. }Og _ _ _ _ _ _ _ _ _ _,--�,� D.PROVIDE PRESSURE RELIEF UNE PLUMBED TO OUTSIDE. D.INSTALL FIRE BLOCKING BETWEEEN <br /> STRINGERS AT THE TOP AND BOTTOM OF EACH RUN <br /> LAUNDRY/ (N)72x4 PERI E.COV ROUSABLE SPACE UNDER STAIR W/ <br /> S' STORAGE <br /> WINDO 12'G.W.B.PER I.B.C.SECTION R302.7. <br /> 3'10" F.0 EXISTING WALL TO REMAIN <br /> a 104 INTERMEDIATE <br /> STIERS SHALL BE <br /> SPACED W/ U <br /> LESS THAN 4'BETWEEN BALUSTERS. <br /> --- FAMILY <br /> - NEW/REPLACEMENT 2.4 STUD WALL G.PROVIDE STAIRWAY ILLUMINATION PER <br /> i.. I.R.C.SECTION R303.8.SEE DIV.01002.6 SHEET A001. <br /> 107 <br /> (IJ) -I_-. <br /> PJ SAFETY GLAZING PER I.R.C.,SECTION R308 <br /> 30148 3-V <br /> m <br /> A.WINDOWS WATHIN 18"OF FLOOR <br /> WINDOW MNJ--I m 8.WINDOWS NTHN A 24'ARC OF DOORS <br /> m CUR..-__ CONTRACTOR NOTE: C.WINDOWS AT TUBS AND SHOWERS <br /> CONTRACTOR TO VERIFY ALL 0.GLAZING IN DOORS <br /> EXISTING FIELD CONDITIONS E.WITHIN STAIRWELLS <br /> O. AND DIMENSIONS. F.LESS THAN 60"HORIZ.FROM THE BOT. <br /> I STAIR TREAD NOSING,8 BOT.EDGE OF GLAZING IS <br /> LESS THAN 36"ABV.LANDINGIWALKING SURFACE. <br /> p_g SEE DIV.08800 SHEET A001. <br /> EGRESS WINDOW PER I.R.C.SECTION R310.SEE DIV. <br /> BATH08600 SHEET A001. <br /> P1 <br /> E 103 IGNITERS FOR GAS FIRED APPLIANCES IN GARAGE <br /> 3'12 TO BE 18'MIN.ABOVE TOP OF SLAB. <br /> VTOS <br /> p 2 SEE DN.15 SHEET A001. <br /> COVER WALLS ADJACENT TO TUBS AND <br /> WITH NON-ABSORBENT MATERIAL TO 2 SAHB QRS <br /> SD/CM I DRAIN INLETS,PER I.R.C.SECTION 307.2. <br /> _ ________ SEE DIV.09250 SHEET A001. <br /> FAMILY I P-8 (2)LAYERS OF FLOOR SHEATHING OVER FRAMING. <br /> 6'112' <br /> 102 <br /> I p_g 7 3/4"MAX.RISER WITH 10-MIN.RUN,IF MORE THAN <br /> (3)RISERS,HANDRAIL REQUIRED PER I.R.C.SECTION <br /> R311.7.4. Job Number 16.009 <br /> SEE DIV.01002.7 SHEET A001. <br /> io File Number 16.009.001.1eyout <br /> P_10 18Y24"DRAWL SPACE ACCESS.INSULATE AND <br /> WEATHER STRIP. <br /> SEE DIV,01002.1 SHEET A001. <br /> (N)72X36 GARAGE 22'00"ATTIC SPACE ACCESS W130"HEAD <br /> CLEAWINDOW 100 SEE DIIVV.01 02.2 S EET A001NCE.INSULATE AND.ATHER STRIP. <br /> p_12 FLOOR MATERIAL BREAK UNE <br /> STORAGE P-13 WALL LINE ABOVE <br /> 101 <br /> WALL LINE BELOW <br /> iry I P-15 FIREPLACE ASSEMBLY NOTES: <br /> Z-n A.DIRECT VENT FIREPLACES,INSTALL PER <br /> MFG.SPECIFICATIONS,SHALL CONFORM TO I.R.C. <br /> ---- ---� REQUIREMENTS.SEE DIV.01002.8 SHEET Al <br /> I - -__� B.ZERO CLEARANCE FIREPLACES SHALL <br /> CONFORM TO I.R.C.REQUIREMENTS. <br /> .01002.8 SHEET A001. <br /> p-2a ( SEE DNC.HEARTH SHALL CONFORM TO I.R.C. <br /> -_ _- <br /> :4= <br /> 1 Permit Submittal 05.09.16 <br /> REQUIREMENTS.SEE DIV.01002.8 AND 8 SHEET A001.(N)72X36 J (N)10'X8' D.FIREBLOCK OPENINGS AROUND <br /> PENETRATIONS AT EACH FLOOR PER I.B.C.SECTION <br /> T B" WINDOW (N) GARAGE RI 003.13. <br /> DO R DOOR 7-6- <br /> R <br /> P-16 SEE SITE PLAN FOR EXTENT OF WALKS AND <br /> DRIVEWAYS <br /> 14'1 12' 18'3" P-17 3"DIAMETER STEEL POST <br /> 32'412' P-16 36"GUARDRAIL PER I.R.C.SECTION R3128TABLE LOWER FLOOR <br /> R301.5.AT STAIR SLOPES AT 34"ABOVE STAIR PLAN <br /> NOSINGS. <br /> P-19 '8'VENT FOR MECHANICAL.1'CLEARANCE ALL SIDES <br /> PER I.R.C.SECTION R1005.3. <br /> LOWER FLOOR PLAN SEE DN.15 SHEET A001. <br /> 1 N P-20 PLANT SHELF <br /> A101 o z 4 B <br /> " " - A1 01 <br /> P-21 UPPER AND LOWER LINEN CABINETS <br /> P-22 SOFFIT AREA <br /> P-23 INTEGRATED MAKE UP AIR <br /> P-24 2x4 STUDS W/R-21 INSULATION MIN.(''j '� <br />