Laserfiche WebLink
type of all braced wall panels. (Let-in diagonal bracing is not allowed in seismic design <br /> category"D", which includes all of Everett). <br /> 6. The plans do not specify wall sheathing, moisture barrier or siding material. <br /> 7. Show how stud walls are supported at the foundation. Specify pressure treated wood in <br /> contact with concrete. <br /> 8. Specify anchor bolt size, spacing, and length of embedment. <br /> 9. Show how proposed garage relates to the rest of the existing structures. <br /> 10. Provide construction details/sections to clearly define how the repairs are to be <br /> constructed. <br /> 11. Provide plans, details and drawings to show how the structure between the existing <br /> house and the existing garage will be repaired (replaced) and how modifications to it will <br /> comply with applicable codes. <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> Jeff Heilman <br /> Development Technician <br /> 425-257-8976 <br /> Email: iheilman@ci.everett.wa.us <br />