2. Vertical fenestration alternate per Section existing structure,or proximity to <br /> C402.4.1.1 for the area adjacent to the new adjacent air intakes/exhausts make full <br /> vertical fenestration added. compliance impractical.Alternate designs shall <br /> 3. Component performance option with target area provide alternate energy savings strategies <br /> adjustment per Section C402.1.5 or the total including,but not limited to,Demand Control <br /> building performance option in Section C407 Ventilation or increased mechanical cooling or <br /> for the whole building. heating efficiency above that required by Tables <br /> C503.3.2.1 Application to replacement C403.2.3(1)through C403.2.3(10). ** <br /> fenestration products.Where some or all of an 2. Qualifying small equipment:This exception <br /> existing fenestration unit is replaced with a new shall not be used for unitary cooling equipment <br /> fenestration product,including sash and glazing,the installed outdoors or in a mechanical room <br /> replacement fenestration unit shall meet the adjacent to the outdoors.This exception is <br /> applicable requirements for U-factor and SHGC in allowed to be used for other cooling units and <br /> Table C402.4. split systems serving one zone with a total <br /> Exception:An area-weighted average of the cooling capacity rated in accordance with <br /> U-factor of replacement fenestration products Section C403.2.3 of less than 33,000 Btu/h <br /> being installed in the building for each fenestration (hereafter referred to as qualifying small <br /> product category listed in Table C402.4 shall be systems)provided that these are high-efficiency <br /> permitted to satisfy the U-factor requirements for cooling equipment with SEER and EER values <br /> each fenestration product category listed in Table more than 15 percent higher than minimum <br /> C402.4.Individual fenestration products from efficiencies listed in Tables C403.2.3(1)through <br /> different product categories listed in Table C402.4 (3),in the appropriate size category,using the <br /> shall not be combined in calculating the same test procedures.Equipment shall be listed <br /> area-weighted average U-factor. in the appropriate certification program to <br /> qualify for this exception.The total capacity of <br /> C503.3.3 Skylight area.The addition of skylights that all qualifying small equipment without <br /> results in a total building skylight area less than or equal economizers shall not exceed 72,000 Btu/h per <br /> to that specified in Section C402.4.1 shall comply with building,or 5 percent of its air economizer <br /> Section C402.4.Alterations that result in a total capacity,whichever is greater.That portion of <br /> building skylight area greater than that specified in the equipment serving Group R occupancies is <br /> Section C402.4.1 shall comply with the component not included in determining the total capacity of <br /> performance option with target area adjustment per all units without economizers in a building. <br /> Section C402.1.5 or the total building performance Redundant units are not counted in the capacity <br /> option in Section C407 for the whole building. limitations.This exception shall not be used for <br /> ** : C503.4 Mechanical systems.Those parts of systems the shell-and-core permit or for the initial tenant <br /> : which are altered or replaced shall comply with Section improvement or for Total Building Performance. <br /> : C403.Additions or alterations shall not be made to an 3. Chilled water terminal units connected to <br /> : existing mechanical system that will cause the existing systems with chilled water generation equipment <br /> : mechanical system to become out of compliance. with IPLV values more than 25 percent higher <br /> than minimum part load efficiencies listed in <br /> Exception:Existing mechanical systems which are Table C403.2.3(7),in the appropriate size <br /> altered or where parts of the system are replaced are not category,using the same test procedures. <br /> required to be modified to comply with Section C403.6 Equipment shall be listed in the appropriate <br /> as long as mechanical cooling is not added to the certification program to qualify for this <br /> system. exception.The total capacity of all systems <br /> All new systems in existing buildings,including without economizers shall not exceed 480,000 <br /> packaged unitary equipment and packaged split systems, Btu/h per building,or 20 percent of its air <br /> shall comply with Section C403. economizer capacity,whichever is greater.That <br /> Where mechanical cooling is added to a space that was portion of the equipment serving Group R <br /> not previously cooled,the mechanical system shall occupancy is not included in determining the <br /> comply with either Section C403.6 or C403.3. total capacity of all units without economizers in <br /> Exceptions: a building.This exception shall not be used for <br /> 1. Alternate designs that are not in full compliance the initial permit(this includes any initial permit <br /> with this code may be approved when the code for the space including,but not limited to,the <br /> official determines that existing building shell-and-core permit,built-to-suit permit,and <br /> constraints including,but not limited to, tenant improvement permit)or for Total <br /> available mechanical space,limitations of the Building Performance Method. <br /> 2015 Washington State Energy Code II CE-121 <br />