My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1520 80TH ST SW HEROUX DEVTECH 2019-08-12
>
Address Records
>
80TH ST SW
>
1520
>
HEROUX DEVTECH
>
1520 80TH ST SW HEROUX DEVTECH 2019-08-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2019 10:05:58 AM
Creation date
5/31/2017 1:08:49 PM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1520
Tenant Name
HEROUX DEVTECH
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2. Vertical fenestration alternate per Section existing structure,or proximity to <br /> C402.4.1.1 for the area adjacent to the new adjacent air intakes/exhausts make full <br /> vertical fenestration added. compliance impractical.Alternate designs shall <br /> 3. Component performance option with target area provide alternate energy savings strategies <br /> adjustment per Section C402.1.5 or the total including,but not limited to,Demand Control <br /> building performance option in Section C407 Ventilation or increased mechanical cooling or <br /> for the whole building. heating efficiency above that required by Tables <br /> C503.3.2.1 Application to replacement C403.2.3(1)through C403.2.3(10). ** <br /> fenestration products.Where some or all of an 2. Qualifying small equipment:This exception <br /> existing fenestration unit is replaced with a new shall not be used for unitary cooling equipment <br /> fenestration product,including sash and glazing,the installed outdoors or in a mechanical room <br /> replacement fenestration unit shall meet the adjacent to the outdoors.This exception is <br /> applicable requirements for U-factor and SHGC in allowed to be used for other cooling units and <br /> Table C402.4. split systems serving one zone with a total <br /> Exception:An area-weighted average of the cooling capacity rated in accordance with <br /> U-factor of replacement fenestration products Section C403.2.3 of less than 33,000 Btu/h <br /> being installed in the building for each fenestration (hereafter referred to as qualifying small <br /> product category listed in Table C402.4 shall be systems)provided that these are high-efficiency <br /> permitted to satisfy the U-factor requirements for cooling equipment with SEER and EER values <br /> each fenestration product category listed in Table more than 15 percent higher than minimum <br /> C402.4.Individual fenestration products from efficiencies listed in Tables C403.2.3(1)through <br /> different product categories listed in Table C402.4 (3),in the appropriate size category,using the <br /> shall not be combined in calculating the same test procedures.Equipment shall be listed <br /> area-weighted average U-factor. in the appropriate certification program to <br /> qualify for this exception.The total capacity of <br /> C503.3.3 Skylight area.The addition of skylights that all qualifying small equipment without <br /> results in a total building skylight area less than or equal economizers shall not exceed 72,000 Btu/h per <br /> to that specified in Section C402.4.1 shall comply with building,or 5 percent of its air economizer <br /> Section C402.4.Alterations that result in a total capacity,whichever is greater.That portion of <br /> building skylight area greater than that specified in the equipment serving Group R occupancies is <br /> Section C402.4.1 shall comply with the component not included in determining the total capacity of <br /> performance option with target area adjustment per all units without economizers in a building. <br /> Section C402.1.5 or the total building performance Redundant units are not counted in the capacity <br /> option in Section C407 for the whole building. limitations.This exception shall not be used for <br /> ** : C503.4 Mechanical systems.Those parts of systems the shell-and-core permit or for the initial tenant <br /> : which are altered or replaced shall comply with Section improvement or for Total Building Performance. <br /> : C403.Additions or alterations shall not be made to an 3. Chilled water terminal units connected to <br /> : existing mechanical system that will cause the existing systems with chilled water generation equipment <br /> : mechanical system to become out of compliance. with IPLV values more than 25 percent higher <br /> than minimum part load efficiencies listed in <br /> Exception:Existing mechanical systems which are Table C403.2.3(7),in the appropriate size <br /> altered or where parts of the system are replaced are not category,using the same test procedures. <br /> required to be modified to comply with Section C403.6 Equipment shall be listed in the appropriate <br /> as long as mechanical cooling is not added to the certification program to qualify for this <br /> system. exception.The total capacity of all systems <br /> All new systems in existing buildings,including without economizers shall not exceed 480,000 <br /> packaged unitary equipment and packaged split systems, Btu/h per building,or 20 percent of its air <br /> shall comply with Section C403. economizer capacity,whichever is greater.That <br /> Where mechanical cooling is added to a space that was portion of the equipment serving Group R <br /> not previously cooled,the mechanical system shall occupancy is not included in determining the <br /> comply with either Section C403.6 or C403.3. total capacity of all units without economizers in <br /> Exceptions: a building.This exception shall not be used for <br /> 1. Alternate designs that are not in full compliance the initial permit(this includes any initial permit <br /> with this code may be approved when the code for the space including,but not limited to,the <br /> official determines that existing building shell-and-core permit,built-to-suit permit,and <br /> constraints including,but not limited to, tenant improvement permit)or for Total <br /> available mechanical space,limitations of the Building Performance Method. <br /> 2015 Washington State Energy Code II CE-121 <br />
The URL can be used to link to this page
Your browser does not support the video tag.