My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2216 127TH PL SE 2017-06-07
>
Address Records
>
127TH PL SE
>
2216
>
2216 127TH PL SE 2017-06-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2017 3:49:33 PM
Creation date
5/31/2017 3:51:14 PM
Metadata
Fields
Template:
Address Document
Street Name
127TH PL SE
Street Number
2216
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R311.8 Ramps <br /> Inside Ram YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal 8.3%slope). Exception R311.8.1 Not allowed in AFH ❑ ❑ <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp ❑ ❑ <br /> changes directions. <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. ❑ ❑ <br /> Outside Ramo YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal 8.3%slope). (Exception R311.8.1 Not allowed in AFH)_ ❑ ❑ <br /> R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp ❑ ❑ <br /> changes directions. <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. ❑ ❑ <br /> *Guards below are depicted vertically as an example only. All Ramps must have Guards <br /> Less than 4" <br /> Handrail both sides <br /> 34"—38" <br /> Guard <br /> 36"min <br /> 3'x3'min <br /> 3'x 3'min — — landing <br /> landing ~~ <br /> 1:12 max slope <br /> 3' <br /> < 3' 8.3 <br /> t min <br /> ADULT FAMI-Y HOME RAMP <br /> per 2009 IRC with WA. ST. AMENDMENTS <br /> *,ALL RAMPS REQUIRE A BUILDING PERMIT* <br /> R311.2 Means of Egress YES NO <br /> R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. ❑ <br /> R325.4 Operable parts of door handles, pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping, pinching or twisting of the wrist(lever-type,emergency egress hardware). The Exit doors �+ ❑ <br /> shall have no additional locking devices. <br /> R311.7 Stairways N/A YES NO <br /> R311.7.4.1 Riser Height: Max riser height shall be 7'/4 inches (8 inches in structures built prior to July 1, 2004) M ❑ <br /> R311.7.4.2 Tread Depth: Min.tread depth shall be 10 inches. (9 inches in structures built prior to July 1,2004) ❑ <br /> R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to ❑ <br /> multiple risers.Handrails shall be installed in accordance with E;311.7.7.1—R311.7.7.4 <br /> R 325.8 Grab Bars in Bathrooms(May require"alternate"approval in accordance with IRC Sec. R104.10 and.11YES NO <br /> R325.8 Grab bars shall be installed for all water closets(toilets),bathtubs and showers_. <br /> Bathing facilities such as tubs and showers;and 19 ❑ <br /> On both sides of the toilet. shall comply with ICC/ANSI Al 17.1 Sections 604.5,607.4&608.3 ❑ <br /> AGI 03—AG 105 Swimmin Pool Spa, Hot Tub YES NO <br /> AG105.2 Must be surrounded by a barrier that is 48 inches high, may have doors and or gates that must have audible ❑ ❑ <br /> alarms when opened. <br /> AG105.5 EXCEPTION:Pools, Spas or hot tubs with a safety cover which complies with ASTM F 1346 ❑ ❑ <br /> ❑ PASSED ❑ CORRECTIONS REQUIRED ❑ PERMIT REQUIRED <br /> INSPECTOR'S SIGNATURE: DATE: <br /> INSPECTOR'S ADDRESS: PHONE: <br /> Application and Inspection Checklist developed by Washington Association of Building Officials (WABO), <br /> in cooperation with Department of Social and Health Services (DSHS) for use by both departments and licensors. <br /> 08/01110 <br />
The URL can be used to link to this page
Your browser does not support the video tag.