installation based only on approved plans that must be on site. Changes to plans must be approved <br /> by both the Engineering &Public Services and Fire Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 <br /> for private fire mains. (Below-ground piping must be installed by Washington State Patrol <br /> Licensed Underground Sprinkler line certified "U" installers. For further information, contact <br /> the State Fire Marshal's Office at(360) 596-3900 or contact the Everett Fire Department at <br /> (425)257-8124.) All such tests shall be witnessed by a Fire Department inspector. Call (425) 257- <br /> 8124 or(425)257-8120 to make an appointment for inspection. <br /> Contractors'materials and test certificates shall be submitted to the Everett Fire Department prior to <br /> issuance of any Certificates of Occupancy. <br /> Call (425)257-8124 for more information. <br /> 12. Sprinkler shutoff valves shall be provided on each floor in every building three or more stories high, <br /> including below-grade floors. <br /> 13. Standpipe systems shall comply with NFPA 14. Standpipe systems shall be installed throughout <br /> buildings where the floor level of the highest story is located more than 30 feet above the lowest level <br /> of the fire department vehicle access, or where the floor level of the lowest story is located more than <br /> 30 feet below the highest level of fire department vehicle access. <br /> This shall apply if the finished top level floor is above 30 feet. <br /> 14. The Snohomish County Emergency Radio System is employed by the City of Everett Fire <br /> Department emergency crews and operates at 800 MHz. Large metal-framed or metal and concrete <br /> buildings can weaken the signal so that communication and,therefore, firefighter safety is <br /> compromised. This structure must meet the requirements of EMC 16.03, Section 510, which <br /> specifically addresses required radio system performance standards in this structure. Your attention <br /> to this feature early in the planning stages will help avoid a costly, last-minute retroactive <br /> installation of radio signal amplification antennae and other equipment. For details, call the <br /> Everett Fire Department Plan Reviewer at(425)257-8124. <br /> 15. Floors and sub-floors at or above grade in buildings(other than parking garages) shall be marked <br /> with numbers, in ascending order,beginning with the number"1" (for the ground floor or first floor), <br /> then 46255, 6635', etc. Letters shall be used only to designate specific areas as detailed below. <br /> Floors below grade in buildings(other than parking garages) shall be marked with the letter"B" <br /> (when there is only one floor below grade). When there is more than one floor below grade, they <br /> shall be marked with the letter`B"followed by numbers, in descending order,beginning with the <br /> number"1" (for the floor immediately below the ground floor or first floor),then"2", 463", etc. <br /> Example—`B1", B2", `133", in descending order. <br /> Mezzanines shall be marked with the letter"M". When there is more than one mezzanine,they shall <br /> be marked with the letter"M"followed by numbers, in ascending order. Example—"M1", "M2", <br /> etc. <br />