Laserfiche WebLink
ROOFING: TRUSSES TO BE DESIGNED&MANUFACTURED PERANSI/TPz <br /> 0 COMPOSITION ROOF: 0 NONPERFD.TYPE 15 FELT. NAIL w 4 GALV. MANUFACTURED <br /> 1. DESIGN BY STATE LICENSED SUBMIT & v <br /> / I () MANUFACTURED AT APPROVED PLANT. SUBMIT o <br /> FASTN'R PER EA PIECE 0/1/2"COX PLYYA SHTG.OR EQUIV.w/1/2'CCX TRUSS DESIGN DRAWINGS TO BUILDING OFFICIAL FOR <br /> 0 0/HANGS. APPROVAL PRIOR TO INSTALLATION&SHIP a ro <br /> 0 ROOF SHTG.TO BE NAILED w/8d 0 6'OC EDGES&12'OC FIELD- DRAWINGS TO JOB SITE WITH TRUSSES DESIGN z u7 <br /> UNBLKO. DRAWINGS TO INCLUDE ALL LOADS,LUMBER INFO., v v <br /> CONNECTIONS,HANGERS,PERMANENT REQ'D. <br /> 22'-0' - BRACING LOCATIONS,&RELATED INFORMATION AS m <br /> SPECIFIED PER R802.10.1. TRUSSES TO BE BRACED <br /> TO PREVENT ROTATION&TO PROVIDE LATERAL <br /> STABILITY PER TRUSS DESIGN DRAWINGS,BUILDING w o <br /> PLANS,&PER BUILDING LATERAL ENGINEERING. p1 n <br /> F — — — — — — — <br /> FIELD CUTS OR MODIFICATION OF TRUSSES NOT = x n a <br /> UNE OL PORCH BELOW I PERMITTED WITHOUT ENGINEER'S CALCS./DTLS _' 3 <br /> 4x6 DF-#2 R-01 AND PRIOR APPROVAL BY THE BUILDING w m W <br /> 1 Z — — — — — — — — — — — — — DEPARTMENT.BOTTOM CHORD OF TRUSSES TO BE a <br /> HED OFF OF NON-BEARING INTERIOR WALLS WITH o <br /> s�— I GABLE END TRUON STC SSTO HAVE VER111 AL MTRUSS CLIP OR EMBERS U <br /> ,,,•;,/ I SIMPS.FOR SIDING. GABLE END TRUSS TO BE <br /> EN <br /> " I I _ I SHEATHED&NAILED PER WALL BELOW. <br /> \ —— ————————— <br /> 12MASTER WALL BR'G I —1————————————L UNE OF WALL BELOW I ATTIC ACCESS PER R807.1 <br /> BEDROOM BATH I ALL BR'G WALLS FOR I 1 22'x30'MINIMUM ROUGH FRAMED OPENING.INSULATE AND <br /> TRUSSES ARE SHADED WEATHERSTRIP DOOR.12'HEIGHT INSULATION DAM.30' <br /> 12'-0" 10'-0" I, I I MINIMUM CLEAR HEADROOM. • <br /> IRC M1305.1.3 APPLIANCES IN ATTICS <br /> ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH <br /> AN OPENING ANO A CLEAR AND UNOBSTRUCTED <br /> PASSAGEWAY LARGE ENOUGH TO ALLOW REMOVAL OF THE <br /> SPECIAL TRUSS SKETCH SCALE J6" _ -O" I PREFAB'W'ROOF TRUSSES 0 24o.c. I LARGEST APPUANCE,BUT NOT LESS THAN 30'HICK&22' <br /> MASTER BEDROOM 6:17.PITCH 22-0 PATTERN I VIDE&NOT MORE THAN 20'LONG MEASURED ALONG THE <br /> CENTERUNE OF THE PASSAGEWAY FROM THE OPENING TO <br /> THE APPLIANCE.THE PASSAGEWAY SHALL HAVE <br /> CONTINUOUS SOLID FLOORING NOT LESS THAN 24'WIDE A <br /> LEVEL SERVICE SPACE AT LEAST 30'DEEP AND 30'WIDE <br /> PROVIDE PLATFORM PER UNIT&CODE REQMNTS. SHALL PRESENT ALONG ALL SIDES OF THE APPLIANCE <br /> WHERE ACCESS IS REQUIRED.THE CLEM ACCESS OPENING <br /> TRUSS MFG TO DESIGN TRUSSES TO SUPPORT I I DIMENSIONS SHALL BE A MINIMUM OF 20'BY 30',&LARGE M Y <br /> ADDITIONAL LOAD.PLATFORM TO BE ELEVATED ABV I ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCEZ�' r o <br /> BOTTOM CHORD TO ALLOW R-49 NON-COMPRESSED ——— —— m N <br /> WSUL BELOW A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE Oc S <br /> REQUIRED PASSAGEWAY OPENING AND RECEPTACLE OUTLET o <br /> \ / SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 70,NC <br /> 306.3.1. <br /> / EXCEPTIONS <br /> I I 1.THE PASSAGEWAY&LEVEL SERVICE SPACE ARE NOT <br /> REQUIRED WHERE THE APPLIANCE CAN BE SERVICED& <br /> REMOVED THROUGH THE REQUIRED OPENING. <br /> 2 WHERE THE PASSAGEWAY IS UNOBSTRUCTED&NOT LESS <br /> STD.TRUSS I THAN 6'HIGH&22'WIDE FOR ITS ENTIRE LENGTH,.THE <br /> PASSAGEWAY SHALL BE NOT MORE THAN 50'LONG. <br /> aw I // ❑ \ I W INSTALL U.L APPROVED ATTIC MOUNTED FURNACE WITH 3 <br /> FLAD <br /> SCISSOR TRUSS I z APPLIANCEINTERNATIONAL o <br /> AUTOMATTICPER GAS FF TMECHANICAL CODE(IMC), m F I NATIONAL FUEL GAS CODE(NFGC-NFPA 54),&PER <br /> W II I MANUFACTURER INSTRUCTIONS m N <br /> L J I Q 3 <br /> z/ � �o <br /> PREFAB ROOF TRUSSES O 24'O.C. I S �J M 3 <br /> COMPOSITION ROOFING <br /> TYPE 15 BUILDING PAPER <br /> �TH.O.S.B.SHEATHING INSTALL 50 5a.R.NET FREE AREA <br /> VENTS AT I'O.C.NEM WALL LINE <br /> ROOF & ATTIC VENTILATION <br /> SPECIAL HOOF TRUSSES 0 24'o.c. I ALL VENTS TO BE SCREENED w/Y4*CORROSION <br /> 6:12 PITCH 22-0 PATTERN RESISTANT METAL MESH. (3)2'9 HOLES PER VENT <br /> BLOCK=7.0 SQ.IN.NET AREA(74X). LOCATE VENT <br /> BLOCKS AT CORNERS&EVENLY BETWEEN FOR ATTICS. <br /> INSTALL VENT BLOCK EA RAPIER SPACE FOR <br /> r` CATHEDRAL ROOFS THE MINIMUM NET FREE <br /> I I I VENTILATING AREA SHALL BE 1/150 OF THE AREA OF <br /> THE VENTED SPACE EXCEPTION: THE MINIMUM NET <br /> Np <br /> y` 'OgH I I I FRET:VENTILATION AREA SHALL BE 1/300 OF THE <br /> AED VERTICALLY <br /> LIG <br /> TOP BEVELED To E31 <br /> HATCH ROOF VENDED SPACE FRONDED THE FOLLOWING CONDITION <br /> I I � I <br /> HOLES WA STATE AMEinMENTs <br /> No VENT nOLES IS MET: AT LEAST 40%AND NOT MORE THAN OS <br /> TAME R302.1(1)FOOTNOTE A: I OF THE REQUIRED VENTILATING AREA IS PROVIDED BY <br /> ROOF EAVE FRE-RESISTANCE RATING <br /> SHALL BE PERMITTED TO BE REDUCED PREFAB <br /> LOCATED IN THE UPPER PORTON OF <br /> To o HOURS ON THE UNDERSIDE OF THE ATTIC OR RAFTER SPACE UPPER VENTILATORS <br /> THE <br /> EAVE R FRE SLOCIaNG Is _ I /�� PREFAB ROOF TRUSSES 0 24 o c I SHALL BE LOCATED NO MORE THAN 3 FEET BELOW m Z <br /> 1/2-GWB PROVIDED FROM THE WALL TOP PUTE `i THE RIDGE OR HIGHEST POINT OF THE SPACE. O <br /> TO THE IRFROMIER TE(IF THE ROOF I 12PIT 0'-D'PATTERN Or <br /> TO TH INc. MEASURED VERTICALLY,WITH THE BALANCE OF THE z <br /> REQUIRED VENTILATION PROVIDED BY EAVE OR CC <br /> o-nouR MON-RATED WALL ;,,,;,•..•,•,,,•,•;/ CORNICE VENTS WHERE THE LOCATION OF WALL OR V) f 3 <br /> 12'GABLE 0/HANG(EYP.) ROOF FRAMING MEMBERS CONFLICTS WITH THE S2 <br /> ILATORS,INSTALLAMON <br /> MORE THAN 3 FEET BELOINSTALLATION OF UPPER W THE RIDGE OR HIGHEST <br /> POINT OF THE SPACE SHALL BE PERMITTED. N < <br /> _ 6x3 DQD1 R-02 — _ _ I EAVE BAFFLES <br /> UNE OF PORCH BELOW FOR AIR PERMEABLE INSULATIONS IN VENTED ATTICS, z <br /> r4 L A BAFFLE SHALL BE INSTALLED ADJACENT TO SOFFIT <br /> — — — — — — — — — — — AND EAVE VENTS.BAFFLES SHALL MAINTAIN AN O OO w <br /> 18'EAVE 0/HANG(TYP.) OPENING EQUAL OR GREATER THAN THE SIZE OF THE F— <br /> TRUSS TAIL EAVE VENT.THE BAFFLE N.T EXTEND OVER THE TOP OF <br /> 12'-0' 10'-0' THE ATTIC INSULATION.THE BAFFLE SHALL BE V) <br /> PERMITTED TO BE ANY SOLID MATERIAL a w <br /> OVERHANG WITHIN 5' OF PROPERTY LINE 22'-0' WSEC.R402.2.3 e <br /> ATTIC <br /> AREA= 812 SF <br /> 812 t 300= 2.71 SF VENTILATION REQ'D <br /> LOWER PART OF ATTIC: <br /> ROOF' FRAMING PLAN SCALE Y'=1'-Q' <br /> INSTALL� o8SF NET NEAR WALL URF 0.347 <br /> UPPER PART OF ATTIC: 5 <br /> INSTALL 1 GABLE VENTS 0 1.04 SF NET EA= pF <br /> 1.04 SF NET <br /> TOTAL VENTING PROVIDED: 3.12 SIF Z-1-1 ii <br />