My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1513 HOYT AVE 2017-06-12
>
Address Records
>
HOYT AVE
>
1513
>
1513 HOYT AVE 2017-06-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2017 2:06:48 PM
Creation date
6/12/2017 2:06:32 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
1513
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.z <br /> PREFAB.ENGINEERED ROOF -6 <br /> PREAB.ENGINEERED ROOF <br /> TRUSSES 0 24"O.C.(U.N.O.) TRUSSES 0 24"O.C.(U.N.O.) <br /> ROOFING PER PLAN a- " <br /> GENERAL SPECIFICATIONS: ROOFING PER PLAN <br /> WIND BAFFLE W/1"MIN.AIR SPACE <br /> CONTRACTOR SHALL VERIFY All SITE CONDITIONS&BUILDING DIMENSIONS,k SHALL =o io a SIMPSON H2.SA OR H1 EACH WIND BAFFLE W/I'MIN.AIR SPACE 3 <br /> REPORT ANY VARIATIONS TO THE DESIGNER FOR RESOLUTION PRIOR TO CONSTRUCTION. m 12 TRUSS TO TOP PLATES o <br /> WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED. SEE 2z SCREENED VENT ELOCK SIMPSON H2.5A OR HI EACH 48 W�' <br /> R-49 INSUL. PLAN W/SIMPSON RBC 0 48" 12 TRUSS TO TOP PLATES ?A <br /> 48 <br /> CODES:2012 INTERNATIONAL RESIDENTIAL CODE(IRC),2�WASHINGTON STALE ENERGY O.C.TO TOP PLATES .- SEE w o <br /> CODE(WSEC).2012 UNIFORM PLUMBING CODE(UPC),2012 INTERNATIONAL MECHANICAL )6"GWB OR 14"SAG o m'`•' <br /> CODE(IMC),AND ALL OTHER APPLICABLE CODES RESISTANT GWB 8d GALV.0 6"O.C. m m PLAN 2x SCREENED VENT BLOCK p%7,5 in <br /> �(DIAPH.TO TOP PLS) _'^ <br /> 2-2x6 TOP PLATES R-49 INSULATION 8d CAM 0 6"O.0 <br /> LOADING LIVE DEAD TOTAL LAP SPLICES 48' (DIAPH.TO TOP PLS.) w ti 3 <br /> ROOF(GROUND SNOW) 25 PSF 10 PSF 35 PSF 26 GA.CONT. )g'GWB OR SAG $ <br /> 4x HEADER PER PLAN. <br /> ATTICS LIMITED STORAGE 20 PSF 10 PSF 30 PSF a ALUM.GUTTER <br /> W 2"R-10 FOAM BOARD PER PLAN RESISTANT)¢"CWB o i3 �'� <br /> te <br /> ATTICS NO STORAGE 10 PSF 70 PSF 20 PSF INSULATION REWIRED. TYPICAL FASCIA GUTTER <br /> DECKS(SEE R502.2.1) 40 PSF 10 PSF 50 PSF SIDING PER ELEV.0/TYPE 2-2x6 TOP PLATES PER PLAN �TY'PICAL FASCIA <br /> EXTERIOR BALCONIES 40 PSF 10 PSF 50 PSF 1/2"G.W.B. 15 FELT OR WATERPROOF LAP SPLICES 48" <br /> FIRE ESCAPES 40 PSF R-21 INSULATION BUILDING PAPER <br /> GUARDRAILS/HANDRAILS 200 LBS AT TOP ANY DIRECTION NAIL KRAFT PAPER FACE TO HEADER PER PLAN.USE 2' °o°o <br /> GUARDRAILS IN-FILL 50 LBS APPLIED TO 1 SO.FT. FREE EDGE OF STUD ORzo FOAM BOARD W/4.HEADER <br /> PASS.VEHICHLE GARAGE 50 PSF IF ELEVATED 2,000 LB PT. PROVIDE 4 MIL.VAPOR BARRIER 0 <br /> ROOMS(NOT SLEEPING) 40 PSF 10 PSF 50 PSF > )r G.W.B. SIDING PER ELEVATION 0/ 0 0 <br /> SLEEPING ROOMS 30 PSF 10 PSF 40 PSF J TYPE 15 FELT OR <br /> SCISSOR TRUSS SECTION <br /> STAIRS 40 PSF 10 PSF 50 PSF R-21 INSUL. WATERPROOF BUILDING PAPER o <br /> OR 3DO LB PT.LOAD ON 4 SO.IN. - WHERE APPLICABLE SCALE: V=1'-0" <br /> 2x6 STUDS 0 16"O.C. <br /> ALL BEAMS,GIRDERS,HEADERS,RAFTERS,&JOISTS TO BE HEM FIR NO.2 OR <br /> ■ <br /> BETTER AS NOTED ON PLANS.GLUED LAMINATED TIMBERS SHALL BE MANUFACTURED )'x'APA T&G OSB OR PLYWD.CD 2x6 BASE PL.W/16d 0 16'O.C. <br /> &IDENTIFIED AS REWIRED IN RITC A190.1 k ASTM D3737. INT,W/EXT.GLUE,NAIL W/ TO JST&2-16d EA STUD <br /> 'T-1-11 PLYWD OR)z"COX <br /> PLYWOOD INDEX:CD. ROOF k 5283(00&SHEATHING8602.94).PER TABLE FASTENERS <br /> TYP.2x6 WALL PLYWOOD SHTG OR�e O.S.B. 10d . 6"O.C.EDGES&SOLID 2x RIM JOIST W/3-I6d <br /> WALL SHEATHING PER TABLE&602.3(3)&&602.3(4).SHEATHING FASTENERS PER 3/4"APA T&G OSB OR PLYWD. NAIL 8d 6"O.C.EDGE,12" BLKG.k 0 10'O.C.IN FIELD EACH JOIST <br /> TABLES R602.3(1)&(2). CD INT.W/EXT.GLUE.NAIL W/ O.C.FIELD OR PER ENGINEER'S <br /> STRUCTURAL MEMBER FASTENERS PER TABLE R602.3(1). 10d 0 6"O.C.EDGESk SOLID SHEARWALL SCHEDULE SOLID BLKG. FLOOR JSTS PER PLAN <br /> WOOD IN CONTACT WITH CONCRETE,NEAR GROUND,OR WOOD EXPOSED TO WEATHER TO BLOCKING&0 10"O.C.IN FlELD 0 SUPPORTS <br /> BE PRESSURE TREATED OR NATURALLY DURABLE WOOD PER R317. SOLID BLOCKING 2x6 BASE PLATE )f"G.W.B. <br /> i <br /> CONCRETE&REBAR: SIMPSON A35 0 32"O.C. 2x RIM JOIST 2-2x6 TOP PLATES I Y <br /> REBAR TO BE 60.000 PSI-GRADE 60 ASTM A706.WALL REBAR SHALL BE PLACED FLOOR JOISTS PER PLAN LAP SPLICES 48" <br /> NO CLOSER TO THE OUTSIDE FACE THAN Ji THE WALL THICKNESS.REBAR COVER PER J4"CCX PLYWOOD SHTG. ZZ o <br /> ACI 318.FOOTINGS TO BEAR ON 1500 PSF MINIMUM UNDISTURBED SOIL CONCRETE 10 OR R O.S.B.SOFFIT HEADER PER PLAN. c m w <br /> USE 2"FOAM BOARD <br /> BE MINIMUM TIO=2500 PSI 0 28 DAYS(3,000 PSI FOR GARAGE/CARPORT ND SLABS, 2-2x6 TOP PLATES R-30 INSUL.W/VAPOR W/4x HEADER o w <br /> EXTERIOR PATIO SLABS ON GRADE,&WEATHER EXPOSED BASEMENT,FOUNDATION LAP SPLICES 48" PER z 3fi"T-1-Tt PLYWD OR 14'CD% <br /> RETARDER WARM SIDE o PLYWOOD SHTG OR 3f,*O.S.B. <br /> WALLS,PORCHES,AND STEPS W/5$-7$MR ENTRAINMENT).MINIMUM DESIGN EQUIV. plA" a "G.W.B. NAIL Bd 6" EDGE,12" <br /> FLUID PRESSURE=35 PCF OR PER SOILS ANALYSIS. CANTILEVER WILL BEAR J �O.C.FIELD D.C.OR PER ENGINEER'S <br /> ON FRAMED WALL OR `- - �, R-21 INSUL. <br /> UFOUNDATION WALL S.W.SCHEDULE. <br /> SP STRUCTURAL CONNECTORS OF EQUIVALENT STRENGTH MAY BE in 2x6 STUDS 0 16"O.C. 2.6 BASE PL.W/t6d 0 16"O.C. <br /> SUBSTITUTED FOR SIMPSON HOLDOWNS,STRAPS,AND CONNECTORS CANTILEVER SECTION TO JST&2-16d EA STUD <br /> WHERE APPLICABLE SCALE: J§'=V-0' -"APA T&G OSB OR PLYWD.CD 2x RIM JOIST W/3-16d <br /> INT,W/EXT.CLUE.NAIL W/ EACH JOIST <br /> 10d 0 6"O.C.EDGES&SOLID 20 PRESS.TRTD,SILL PLATE W/ <br /> �._2.• Tui BLKG.&0 10.O.C.IN FIELD Jf"0 A.S.0 48"O.C.OR PER PLAN 3 0 <br /> 1UEsx•6m-Wa wTH &8TWN.4Y2"&12"OF SILL ENDS. <br /> PROVIDE N0.4 VERTICAL m N ao <br /> afiarrr SIACE:w"ii SOLID BLKG. FLOOR JSTS PER PLAN EMBED 7'MINIMUM.INSTALL 3x3A m �' <br /> 6" BARS AT A SPACING N01 a TER AT MT. O SUPPORTS PLATE WASHERS. <br /> CONTINUOUS 14 HORIZ.BAR xAxoTux To smPOxT 200 m. Q F 3 <br /> TO BE LOCATED 6"BELOW IN. EXCEEDING 48 O7CHES. wAo"s D x Axr <br /> TOP OF WALL IRC&404.1.4.2 ° C11O"' 18"MIN.CLEARANCE m FINISHED GRADE SLOPED FOR Z v <br /> STEM WALL&FTG. m d <br /> PER PLAIN CONCRETE 6"MIN.FALL NITHIN IO'OR o <br /> sv0°FAa PcPIiMTs 12"MIN UNDER BEAMS i PROVIDE SWALE OR DRAIN. (� o <br /> _ FOUNDATION DETAIL 'x 3 <br /> `� REBAR z Wr vx6ar R-301NSULATION x_ � C M <br /> Ti "OT P"s INSUL.PLUMBING&MECH. T C Z <br /> °o GRADE TO Tc ROOF DRAIN 4"TIGHTLINE <br /> U• - INT.GRADE 6 MIL BLACK POLY BARRIER. 4 6^ 414 SEPARATE FROM FTG.DRAIN <br /> FA¢xuT W P.TO LAP EDGES 12"MINIMUM <br /> +4 BAR W/ V - Ord aTS sucSul 1•_3^ 4"0 PERF PIPE IN WASHED <br /> 12d MINIMUM Ij° 1' 4"0 ROOF a ac io&K'G,Sao �e GRAVEL CONNECT TO <br /> HORIZONTAL ,I 3"MIN. DRAIN• APPROVED DISCHARGE <br /> .c EXTENSION TWO STORY SECTION <br /> i 4"0 PERF. K cxa a r.us A� <br /> SID.HOOK FTC.DRAIN •a fLLFWS uxom 51" <br /> .+rxr Ac¢ssxut WHERE APPLICABLE SCALE: <br /> R GRAVEL y 2.TarA1K:T.aP.cas 6•SPHJ6:WY <br /> &405.1 i III PAss Trw <br /> 2" � �xrXr roTr rf wnxs LT_O <br /> Or <br /> all ,Y <br /> MIN. II, / `��`` sxxu MOT a LESS Tx <br /> II s z m 2.12 STxmuAS m surwAr sero. <br /> O 16"QC YA% T2x6TM 9x s x' <br /> :�a rxrur w TM 2x4 RAIL AND CAP <br /> io '.JT N FOR M Aa+"�xT °YrC110M OF TaA`� Jf'0 HOG THREADED ROD 36'MIN.HEIGHT <br /> w s Pm 1ec ama 2x2 PICKETS SO THAT A 4" <br /> w/NUTS&WASHERS VAPOR BARRIER TO EXTEND SPHERE MAY NOT PASS THRU o <br /> IF FOOTING POURED SEPARATELY, ff&2)CONTIN.i4 HORIZ, BETWEEN HWSE AND LEDGER SECURE W/3-16d GALV.RAIL W. <br /> PROVIDE 14 BAR 48"O.C.NAX. 3-4FROM BOT. STAIR DETAIL scux:i'"r-c SIMPSON DTT2Z OR E0. TO RESIST 200 LB LOAD IN <br /> NTH STD.HOOK.EXTEND TO 3" FTG. DECK TENSIONTIE. ANY DIRECTION.PICKET TO O z <br /> UR.FROM BOT.OF FTC.ROTAII; 0"MIN. 1 STORY INSTALL IN 2 LOCATIONS APPROVED RESIST 50 LB LOAD APPLIED TOHORIZ.EXTENSION PARALLEL TO ALONG DECKDECKING 1 SQ.FT.OF AREA.3"MIN.2 STORY �•V 3 <br /> WALL FOR PROPER CONIC.COVER. 1'-11'MIN. 3 STORY JOISTS FRAMING FROM OPPOSITE SIDES OVER A V <br /> NOTE: RAILING NOT REDD.ON x=—a - <br /> -ROOF DRAIN TO BE SEPARATE FROM FOUNDATION DRAIN BEARING$UPPIXTT SHALL LAP A MINIMUM OF 3 FLOOR JOISTS PER PLAN :DECK JOISTS PER PLAN DECKS W/IN 30"OF FINISHED <br /> INCHES AND SHALL BE NAILED TOGETHER WITH ————————— <br /> PLAIN C 0 N C. F N D. DETAIL A MINIMUM THREE 10d FACE NAILS.SOLID 3/4-APA T&G OSB OR PLYWD.CO \ GRADE N a <br /> BLOCKING SHALL BE PROVIDED AS LATERAL INT.■/EXT.GLUE.NAIL r/lOd 0 2x LEDGER W/M1L. `2x RIM JOIST I w <br /> SEISMIC ZONE b" SCALE: =I'-0" RESTRAINT AT EACH INTERMEDIATE SUPPORT. 6"O.C.EDGES&SCUD BLKG.&0 HANGER BRACKETS. <br /> " HANGE LAGS 0 SOLID BLOCKING ti <br /> TOE NAIL JOISTS AND BLOCKING TO BEAM./ 10.O.C.IN FIELD �+ 170.4.INTO HOUSE0BEAM PER PLAN CONN. N z <br /> (3 p- RIM JOIST OR PER POS.CONNECT TO COL. vi <br /> FLOOR'�S� BEAM-COLUMN CONNECT ENGINEER'S DETAIL 2x4 SCAB TIE OR METAL O ®z <br /> PER PLAN .n IA LATERAL BRACING CONNECTOR EA,SIDE _ <br /> 2x4 OR 2x6 TIES w/2-16d OR ci z <br /> METAL CONNECTOR 0 UNDERSIDE OF JSTS COLUMN PER PLANS <br /> BEAMS&COLUMNS 0 BEAM&COLUMN NOTE: ALL WOOD PROVIDE KNEE w <br /> PER FOUNDATION PLAN. TYPICAL EA SII E — EXPOSED TO WEATHER BRACES TO RESIST o <br /> COLUMN BASE UP 8"OR TO BE PRESS.TRTD. LAT.FORCES IF COL. U <br /> USE PRESSURE TREATED PROTECT COLUMN BAS: OR HAVE NATURAL EXCEEDS 4'HT. <br /> CONCRETE FOOTING ��w/TYPE 90 ROOFING RESISTANCE TO DECAY <br /> PER FWNDATI IN PLAN COLUMN-FOOTING ANCHOR <br /> INTERIOR GRADE ■/MASB OR EOUIV. GRADE _ SIMPSON COL.BASE PER <br /> s MFGR.SPECS. <br /> INT. BEARING SUPPORT .. CONCRETE FOOTING PER <br /> WHERE APPLICABLE SCALE: 1'-0" 6 <br /> DECK DETAIL FOUNDATION PLAN <br /> �"= OR <br /> WHERE APPLICABLE SCALE: I'-0' <br />
The URL can be used to link to this page
Your browser does not support the video tag.