My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 MERRILL CREEK PKY A T AND T WIRELESS ANTENNA 2018-11-19
>
Address Records
>
MERRILL CREEK PKY
>
2215
>
A T AND T WIRELESS ANTENNA
>
2215 MERRILL CREEK PKY A T AND T WIRELESS ANTENNA 2018-11-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2018 8:02:36 AM
Creation date
6/22/2017 10:36:28 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2215
Tenant Name
A T AND T WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL GROLN-100 NOTES. d <br /> KEY NOTES- 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND 13.CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO V N <br /> CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. U <br /> SURGE SUPIRESSOR GROUNDING, #2 AWG STRANDED 2. ALL GROUNDING SHALL CONFORM TO THE CURRENT AT&T STANDARDS. 14.USE OF 90'BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN > <br /> EXISTING 150'-0" HIGH MONOPOLE O GREEN INSULATED COPPER CONDUCTOR TO 45"BENDS CAN BE ADEQUATELY SUPPORTED. <br /> COLLECTION GROUND BAR AT ANTENNA LEVEL OF 3. CONDUIT ROUTINGS ARE SCHEMATIC.CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO d <br /> 2O EXISTING AT&T LOW PROFILE ANTENNA PLATFORM MONOPOLE EQUIPMENT IS NOT BLOCKED. 15.GROUND RING SHALL BE LOCATED A MINIMUM OF 24'BELOW GRADE OR 6'MINIMUM BELOW D <br /> THE FROST LINE. <br /> EXIST NG COLLECTION GROUND BAR FINAL GROUND 4. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND <br /> CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR 16.INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0"FROM EQUIPMENT <br /> CONDUCC2TOR TO MASTER GROUND BAR AT BASE OF L <br /> 3O EXISTING AT&T ANTENNA,NP. O LEAD,1AWG STRANDED GREEN INSULATED COPPER DAMAGE TO THE CONDUIT. CONCRETE PAD, SPREAD FOOTING,OR FENCE. ■ L z <br /> O <br /> 4O EXISTING MASTER GROUND BAR AT BASE OF MONOPOLE MONOPOLE 5. PREFABRICATED SHELTER WILL BE PROVIDED WITH INTERNAL WIRING AND EQUIPMENT INSTALLED. 17.EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED <br /> FOR COMPLETEINTERNAL WIRING AND ARRANGEMENT REFER TO DRAWINGS PROVIDED BY SHELTER SPRAY, <br /> EXISTING COLLECTION GROUND BAR MANUFACTURER. O <br /> 10 L <br /> O5 EXISTING MASTER GROUND BAR FINAL GROUND LEAD TO 18.OBSERVE N.E.C.AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING N <br /> EXISTING TOWER GROUND RING 6. FOR INTERIOR EQUIPMENT LAVOUi AND LOCATION,SEE SHELTER MANUFACTURER'S DRAWINGS AND � I' <br /> ANTENNA <br /> IN CASE OF CONFLICT THE DRAWINGS GOVERN. 19.GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS O J U <br /> ANTENNA GROUNDING, r2 AWG STRANDED GREEN INSULATEDO OR AT GROUNDING POINTS PROVIDED(2 MINIMUM)COPPER CONDUCTOR TO COLLECTION GROUND BAR A7 7. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC(CADWELD). Q i <br /> ANTENNA LEVEL OF MONOPOLE 8. ALL GROUND CONNECTIONS ABOVE GRADE(INTERIOR&EXTERIOR)SHALL BE FORMED USING TWO 20.MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. <br /> RRH GROUNDING, 2 AWG STRANDED GREEN INSULATED (2)HIGH PRESS CRIMPS. 21.MINIMUM BENDING RADIUS FOR GROUNDING CONDUCTORS IS 8"WHEN BENDING IS LL <br /> M NECESSARY.GROUND CONDUCTORS ARE TO BE AS STRAIGHT AS POSSIBLE. W n <br /> COPPER CONDUCTOR TO COLLECTION GROUND BAR AT 9. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP&HAVE A (n <br /> ANTENNA LEVEL OF MONOPOLE VERTICAL SEPARATION OF 6"FOR EVERY ADDITIONAL CONNECTION. 22.NO SPLICES PERMITTED IN GROUND CONDUCTORS. <br /> 10.ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT THEIR MATING SURFACES AND 23.ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S SPECIFIED W <br /> INSTALL PER MANUFACTURER'S RECOMMENDATIONS.ALL EXTERIOR GROUND CONNECTIONS SHALL BE VALUES. <br /> COATED WITH A CORROSION RESISTANT MATERIAL. <br /> 24.GROUND BARS SHALL NOT BE FIELD MODIFIED. 19 <br /> 11.ALL EXTERIOR GROUND CONDUCTORS SHALL BE/2 AWG TIN PLATED COPPER UNLESS OTHERWISE 1)))) <br /> INDICATED. 25.ALL HORIZONTAL FENCE SECTIONS TO BE GROUNDED WITH B"SINGLE BARREL GROUND <br /> STRAPS. <br /> 12.GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL.WO 10-FT. LONG,AND <br /> SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18"BELOW FINAL GRADE OR 6"BELOW FROST 26.USE PANT SCHEME FOR LOADING ON MOB AS DISCUSSED IN NSTD 119.33&36. <br /> UNE FOR MAXIMUM DEPTH. <br /> 22"x34"SCALE:NONE <br /> GROUNDING NOTES 11"x17"SCALE:NO NE <br /> C"P- <br /> 3 ASSOCIATES <br /> 19401 40TH AVE.W.,SUITE 304 <br /> LYNNWOOD,WA 98036 <br /> 6 `j PHONE:(425)740-6392 <br /> a FAX:(426) 14 <br /> m `&` <br /> Schematic of theft Deterrent Solution et cellular Site at&t WWW.CAMPASSOCSSOC.COM <br /> 7 <br /> DATE: s/2•/16 <br /> \\ ONA6 T <br /> U° v,unr. DRAWN BY: GA <br /> &®'rAD�q��9 n�r,•1 <br /> I� CHECKED BY: IN <br /> ono° ((p6SS "��'��A1 <br /> REVISIONS <br /> REV. <br /> REV <br /> V .: DATE: DESCRIPTION: BY: <br /> 01/15/16 <br /> ISSUED FOR <br /> / OO <br /> Q /� CD REVIEW GA <br /> " ISSUED FOR <br /> � 3/21/16 FINA_ CONSTR. GA <br /> �O t.IAAF. <br /> O <br /> 1 ( 1 10 <br /> L <br /> l 772 <br /> REGISTERED <br /> ARCH' ECT <br /> U UL <br /> T T OF ASHINGTON <br /> 03/23/2016 <br /> ( / LEGEND <br /> Theft Deterrent Composite Cable. <br /> ERICO CC5AO5CB(AT&T Part <br /> Number CE015.128,Rosenberger •' "°"""'a"""`, "tee' -T-- i7 a <br /> .o '�*a44a" rae—Ae-.,.cxw.,vrr .- .c..tcs V K I! <br /> F C I 0--5 <br /> Y Part Number:WR•5TOC4BLE250 <br /> / ^"�� ma ro�xcT�roMs�wrt�s+�usxi 2i .i �'Y�i'i ,,^2�_'/ ='✓.rVv <br /> cc aw u, <br /> % R2 AWG Solid Tinned Copper rar "�`p2MO� <br /> r w5.m EVt=RST-, WA 952D3 <br /> / - �cuArca ra*namtx wrn rc :em wren <br /> ` 141ire Bare.Below Grade <br /> 4Anurr,aLA fi:a isuxr�c3*@E �TA�vt(E•'- <br /> TYp'O TO:.0 R4TNS E. 4-'1vE0 <br /> �'•�•� rgM(gN Ox LTtT 4GYpi M[tll^„r <br /> G60 tll.r i <br /> IFAI1 :'oaxial and Other Feeders SHEET TITLE <br /> 5 a <br /> a ANTENNA GROUNDING PLAN& <br /> NOTES <br /> ANTENNA GROUNDING PLAN 22"x34”SCALE 114" -0" THEFT DETERRENT GROUND ARRANGEMENT 22"x34" <br /> SCALE:NONE E-1 .0 <br /> _1 .O <br /> 11"X17"SCALE 1l4"=1'-0" 11"x17"SCALE:NONE 3 <br /> JOB No. SN89 <br />
The URL can be used to link to this page
Your browser does not support the video tag.