My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 MERRILL CREEK PKY A T AND T WIRELESS ANTENNA 2018-11-19
>
Address Records
>
MERRILL CREEK PKY
>
2215
>
A T AND T WIRELESS ANTENNA
>
2215 MERRILL CREEK PKY A T AND T WIRELESS ANTENNA 2018-11-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2018 8:02:36 AM
Creation date
6/22/2017 10:36:28 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2215
Tenant Name
A T AND T WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TO ANTENNAS "O <br /> — 12"TO 24" <br /> ANTENNA CABLE i 'n <br /> ' U <br /> Type GT Type TA RXO TXO RX1 WEATHERPROOFING KIT <br /> THROUGH CABLE TO TOP OF TEE OF HORIZONTAL RUN WEATHERPROOFING KIT 2-1/2"0 MAX. d <br /> GROUND ROD. AND TAP CABLES. JUMPER REQUIRED (SEE NOTE 3 ` <br /> Type VV Type VS ONLY FOR 1%"0 COAX STANDARD GROUND KIT <br /> THROUGH VERTICAL CABLE TO CABLE TAP DOWN AT 45"' TO OR FOR EASE OF (TYP.) CABLE GROUND KI .� <br /> VERTICAL STEEL SURFACE OR VERTICAL STEEL SURFACE OR CONNECTION (TYP.) REFER TO NOTE. CO AWG STRANDED O <br /> TO THE SIDE OF EITHER SIDE OF HORIZONTAL OR COPPER GROUND WIRE66 <br /> HORIZONTAL OR VERTICAL VERTICAL PIPE. (GROUNDED TO <br /> ANTENNA CABLE IN Q <br /> PIPE. CONNECTOR CABLE TRAY TO GROUND BAR) (SEE L <br /> Type VN Type HS KEA(HHEPRPROOFING EQUIPMENT LOCATION NOTE 1 & 2) (0 <br /> HORIZONTAL CABLE TAP TO REFER TO NOTE 2 (TYP') CONNECTION OF COAX GABLE GROUND J v <br /> HORIZONTAL CABLE TAP TO HORIZONTAL STEEL SURFACE (((JJJ Type GR <br /> VERTICAL STEEL SURFACE OR OR PIPE. CABLE OFF Type GY YP KIT TO ANTENNA GABLE Q 2 <br /> THE SIDE OF HORIZONTAL COLLECTION GROUND <br /> SURFACE. <br /> PIPE. THROUGH CABLE TO SIDE OF <br /> CABLE TAP TO TOP GROUND BAR MOUNTED <br /> GROUND ROD FROM ANTENNA FRAME N6 AWG NEAR/BELOW ANTENNA. <br /> SUPPORT REFER TO DETAIL 5, 1n <br /> THIS SHT. NOTES: Z <br /> 1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND <br /> NOTE: ca, B" ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. <br /> CAD WLES - CONSULT WITH PROJECT TB 2 'n <br /> Type NC MINIMUM ELL "TYPES" SHOWN ABOVE ARE Type X �D RADIUS <br /> EXA .GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT {./ > <br /> MP2 AWG STRANDED, WITH TWO-HOLE LUG. <br /> MANAGER FOR SPECIFIC TYPES OF CROSS OF HORIZONTAL FROM ANTENNA MAST <br /> CADWELD TO BE USED FOR THIS CABLES LAPPED AND NOT THROUGH AND TAP CABLES #2 AWG AIR TERMINALS (WHEN INSULATEDCOPPER CONDUCTOR BONDED WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD <br /> RANDED. INSULATED COPPER <br /> PROJECT. CUT. TO GROUND ROD 3 <br /> REQUIRED) CONDUCTOR. TO GROUND WIRE SHRINK SHALL NOT BE USED. <br /> ALONG CABLE TRAY TO <br /> EXTERIOR GROUND BAR, <br /> 22"z34"SCALE:NONE -".-"SCALE:NONE <br /> CADWELD DETAILS 11"X17"SCALE:NONE 1 COAXIAL CABLE GROUND WIRE TO GROUND BAR CONNECTION 11"X17"SCALE:NONE <br /> GROUND BAR NOTES: STRANDED CU WIRE <br /> VERIFY THE HARDWARE (NUTS/BOLTS/WASHERS) FOR WITH GREEN, 60OV, "D <br /> INSTALLING THE GROUND BARS AND CONNECTING THE THHN/THWN ASSOCIATES <br /> WIRE LUGS TO THE GROUND BARS ARE STAINLESS STEEL INSULATION. SIZE AS <br /> FOR OUTDOOR APPLICATIONS AND NON-CORROSIVE SPECIFIED -4i SCHEME SPECIFICATIONS: <br /> (COPPER, GALVANIZED STEEL, STAINLESS STEEL 19401 40TH AVE.W.,SUITE 304 FOR SS NUT PRODUCER (P1 <br /> INDOOR APPLICATIONS. TWO-HOLE LUG, li392 <br /> 98036 <br /> COAXIAL GROUND KITS W/ LONG CONNECTS TO WIRELESS EQUIPMENT CABINETS, CABLE ENTRANCE PHONE:(d25)740 <br /> 392 <br /> BARREL COMPRESSION LUGS W <br /> SEE HARDWARE CONFIGURATION ON RIGHT / SS SPLIT LOCK WASHER BOLTED TO GROUND GROUND BAR (CEGB), MAIN DISTRIBUTION FRAME GROUND BAR FAX:(425)224-1614 <br /> TWO (2) 3y" BOLTS AND LOCK BAR USING%"-16 x (MDFB), AND STANDBY ENGINE-GENERATOR SET FRAME AND OTHER WWW.CAMPASSOC.COM <br /> HARDWARE TO BE 36"/ MATCH EXISTING GB HOLES Q'i WASHERS (TYP.) SUPPLY AND NOISE PRODUCING EQUIPMENT <br /> HARDWARE ACCEPTABLE IF GB HAS Y," HOLES AND LUGS INSTALLED BY CONTRACTOR. SS FLAT WASHER HE STAINLESS STEEL <br /> ARE Y') HEX HEAD BOLTS AND ABSORBER (A1 <br /> (p2) TWO HOLE HARDWARE. flu� DATE: 3/2'/16 <br /> CONNECTS TO THE EARTH ELECTRODE SYSTEM INCLUDING CENTRAL <br /> SANDWICHING THE BAR IS ALLOWABLE AFTER THE FACE COMPRESSION LUG P O N O I OFFICE GROUND GRID, BUILDING STRUCTURAL GROUND, METALLIC G, <br /> ( GROUND BAR ON WALL, DRAWN BY: <br /> OF THE BAR IS FULL AND LOCAL AT&T APPROVES IN Q O WATER PIPE SYSTEM, ANTENNA SUPPORTING STRUCTURE GROUND <br /> LIEU OF LARGER-2nd BAR) APPLY 'NO OX' FLOOR ANTENNATOWERO O 000 <br /> O O O 000 <br /> O O O SYSTEM, AND ELECTRICAL SERVICE ENTRANCE GROUND CHECKED BY: Pk <br /> VON—ISOLATED (N) <br /> O C C: CONNECTS TO EQUIPMENT NOT IN AN ISOLATED GROUND ZONE (IGZ) <br /> CAD WELD WITH #2 SUCH AS CBN EQUIPMENT FRAME GROUNDS AND DC GROUND <br /> AWG SOLID TINNED CONDUCTORS FOR DC POWER SYSTEMS THAT SERVE CBN OR BOTH REVISIONS <br /> BARE CU WIRE OR CBN AND IBN EQUIPMENT REV.: DATE: DESCRIPT ON: BY: <br /> BUS BAR STRANDED CU WIRE 01/15/16 ISSUED FOR GA <br /> NOTE WITH GREEN, 60OV, ISOLATED (1) D REVIEW <br /> NEVER DRILL THE GB THHN/THWN INSULATION CONNECTS TO THE SINGLE POINT CONNECTION BAR (SPCB), FOR IBN 3 ISSUED FOR <br /> NO DOUBLE STACKING SS FLAT WASHER TO ANTENNA EQUIPMENT Q /21/16 ISSUED <br /> ON TR. GA <br /> NO OVERLAPPING WASHERS STRUCTURE, BUILDING., <br /> RING GROUND OR MOB <br /> SS BOLT <br /> - _ 22'X34"SCALE:NONE SCALE:NONE <br /> GROUND BAR HARDWARE 11"x17 SCALE:NONE 3 GROUND BAR CONNECTION DETAIL AND NOTES 11'YITSCALE:„�„E 4 <br /> #2 AWG STRANDED JUMPER W/ <br /> SHORT BAREL COMPESSION LUGS 772 <br /> GENERAL NOTES (T&B k54205 OR N5407), USHER REGISTERED <br /> STAR WASHERS, LOCK WAS <br /> 1. ALL CADWELD CONNECTIONS ON GALVANIZED AND SHEET METAL SCREWS TO A R C H I ECT <br /> SURFACES SHALL BE CLEANED THOROUGHLY SECURE TO EXTERNAL GROUND R <br /> AND COVERED WITH TWO (2) COATS OF BY CONTRACTOR. <br /> SHERWIN WILLIAMS GALVANITE PAINT B350W3 <br /> OR EQUAL. <br /> COAXIAL GROUND KITS W/ LONG U L N 1 <br /> 2. ALL ELECTRICAL CADWELD AND MECHANICAL BARREL COMPRESSION LUGS W/ <br /> GRONONUOXIDATION ND CONNECTIONS <br /> COMPOUND APPLIED TO TWO ER 3§" BOLTS AND LOCK T E OF ASHINGTON <br /> CONNECTION. WASHERS (BYPC SUPPLY AND <br /> INSTALLED BY CONTRACTOR. D;/2?i2016 <br /> 3, ANY METAL OBJECTS WITHIN 6 FEET OF THE O O <br /> EXTERNAL GROUND RING SHALL BE GROUNDED. <br /> 4. ALL GROUNDING MATERIALS AND CADWELD _�_ Vis" DIA. CNP.) <br /> MOLDS, SHOTS, ETC., SHALL BE FURNISHED _ _ SN89 <br /> AND INSTALLED BY CONTRACTOR, UNLESS `'4�0 0O 4" x 10" x Y."THK. COPPER <br /> OTHERWISE NOTED. �' GROUND BAR W/ 4" INSULATED MJKILTEO HEIGHTS <br /> 5. THE ELECTRICAL CONTRACTOR SHALL FOLLOW STAND OFF. (HANGER NGBI-14410) 2215 MERRILL CREEK PKWY <br /> GROUNDING SYSTEM INSTALLED AND TESTING O SUPPLY AND INSTALL BY EVERETT, WA 98203 <br /> GROUNDING <br /> CONTRACTOR <br /> /2 AWG INSULATED STRANDED <br /> 1y4" 1" 1" COPPER CONDUCTOR DOWNLEAD TO <br /> MASTER GROUND BAR OR OTHER <br /> 1p• FINAL GROUNDING POINT SHEET TIT-E <br /> GROUNDING DETAILS <br /> S' LC- NUMBER <br /> NOT USED 22"x34"SCALE 112"c1'-0" 'x37 SCALE NONE 6 COLLECTION GROUND BAR 2z x34"SCALE:NONE 7 <br /> 11"z17"SCALE I/4"=1'-0" NOTES E- .O <br /> it"X17"SCALE:NONE <br /> JOB No. SN89 <br />
The URL can be used to link to this page
Your browser does not support the video tag.