� ■ � • • <br /> 2012 W ashington State Energy Code Compliance Forms for Commerci2l,Group R1,and>3 story R2 and R3 Re�ised June 2013 <br /> Project Address People's Bank Date 5/22/2015 <br /> The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 <br /> WSEC. NOTE:Define print area in Excel prior to printin MECH-CHK pa es. <br /> Applicability Code Section Code Provision Information Required Location Building Department <br /> (yes,no,na) on Plans Notes <br /> COMPLEX SYSTEMS,CONTINUED <br /> Specific System Requirements <br /> N A C403.42 8� Variable Flow control-fans Indicate fans requiring variable flow control and method <br /> � C403.2.12 <br /> C403.4.2.1 VAV fan static pressure Indicate sensor locations on plans:include at least one sensor per major <br /> N/A sensors duct branch <br /> C403.4.2.2 VAV fan static pressure Indicate fan system static pressure setpoint based on zone requiring most <br /> N�A set oint pressure <br /> VAV systems serving multi- Indicate supply air systems serving multiple zones that are required to be <br /> C403.4.5 VAV,method of primary air control,and zones served;note exceptions <br /> N/A zones taken <br /> N/A C403.4.5.4 VAV system suppty air reset Indicate controls that automatically reset supply air temp in response to <br /> loads <br /> N/A C403.4 Large capaciry cooling Indicate method of multi-stage or variable control for building cooling <br /> s stems s stem ca aci >300 tons <br /> N/A C403.4.7 Hot gas bypass limilalion Indicate cooling equipment unloading or capacity modulation method <br /> C403.4.3 Large capacity boiler Indicate multi-stage or modulating burner for single boilers>500,000 btuh <br /> N/A s stems <br /> N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers <br /> C403.4.3.5 Chiller/boiler plant pump Indicate capability to automatically reduce overall plant flow and shut-off <br /> N/A isolation flow through chillers&boilers when not in use <br /> C403.4.2& Variable flow control- Indicate pumps requiring variable flow control&method <br /> N/A C403.4.3.6 pumps <br /> N A C403.2.12.1 Variable flow control- Indicate cooling tower fans requiring variable flow control and method <br /> � &C403.4.4 coolin towers <br /> N/A C403.4.3.4 Hydronic system part load reset supply water temp AND reduce flow by?50°/for systems>300,000 <br /> controls <br /> N/A Two-pipe changeover Indicate deadband,heating/cooling mode scheduling and changeover <br /> C403.4.3.2 s stems tem erature range <br /> C403.4.3.3.1 Water loop heat pump- Indicate capability of central equipment to provide min.20°F water supply <br /> N/A deadband tem deadband between heat re'ection and heat addition modes <br /> C403.4.3.3 Water loop heat pump- Provide heat exchanger that separates cooling tower and heat pump loop <br /> N/A heat re ection in Climate Zone 5 <br /> C403.4.3.3.3 Water loop heat pump- Indicate 2-way isolation valve on each heat pump and variable flow control <br /> N/A isolation for s stems with total um ower>10 h <br /> C403.4.6 Condenser water heat Indicate system provided to pre-heat service water and efficiency <br /> N�A recovery <br /> C403.5 Cooler/(reezer-anti-sweat Indicate w/sf&control method for walk-in cooler/freezer door anti-sweat <br /> N/A heaters heaters <br /> N/A C403.5/6 Cooler/freezer-evaporato�Indicate motor type for evaporator and condenser fans<1 hp <br /> SERVICE WATER HEATING <br /> Service Water Systems <br /> C404.2 Water-heating equip min. Provide equipment schedule or complete MECH-SUM table with type, <br /> YE$ efficienc ca acit efficienc ,lest standard or other ef(icienc source M 1.0 <br /> YES C404.3 Temperature controls Indicate temperature controls have required setpoint capability <br /> YE$ C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply& M 1.0 <br /> dischar e <br /> YE$ C404.5 Insulation underwater Indicate R-10 insulation under tank M4.0 <br /> heater <br /> YE$ C404.6 Service water piping Indicate R-value of insulation on piping;note exceptions taken <br /> insulation M4.0 <br /> C404.7/g Circulation systems and Indicate shut-off capability based on occupancy and periods of limited <br /> N/A heat trace shut-off demand <br /> N/A C404.9 Group R-2 service hot water Indicate method of usage metering for dwell.units served by central HW <br /> r <br /> Pools&In-Ground Permanently Installed Spas <br /> Pool heating equip min. Provide equipment schedule or complete MECH-SUM table with type, <br /> C404.10.1 capacity,efficiency,test standard(or other eff.source);heat pump heaters <br /> nf�A efficiency 4 COP <br /> > <br /> N/A C404.10.1!2 Pool heater on/off controls Indicate automatic on/off control based on scheduling&accessible on/off <br /> switch on heater that o erates inde endent of thermostat settin or <br /> N/A C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required <br /> N/A C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to>90'F <br /> N/A C404.10.4 Heat recovery Indicate method,exhaust air temperature reduction and recovered energy �%/ // � <br /> �., ,r,� <br />