My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2702 COLBY AVE PEOPLES BANK 2021-04-20
>
Address Records
>
COLBY AVE
>
2702
>
PEOPLES BANK
>
2702 COLBY AVE PEOPLES BANK 2021-04-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2021 3:52:29 PM
Creation date
6/28/2017 9:21:53 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2702
Tenant Name
PEOPLES BANK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ • � • • <br /> 2012 Washington State Energy Code Compliance Forms for Commercial.Group R1,and>3 story R2 and R3 Revised�une zoi 3 <br /> Project Address People's Bank Date 5/22/2015 <br /> The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 <br /> WSEC. NOTE:Define print area in Excel prior to printin MECH-CHK pages. <br /> Applicability Code Section Code Provision Information Required Location Building Department <br /> (yes,no,na) on Plans Notes <br /> GENERAL PROVISIONS,CONTINUED <br /> HVAC System Controls&Criteria,Continued <br /> C403.2.12 Variable flow control- Indicate fan&pump motors requiring VF control&method(VSD or equiv <br /> N/A fans/ um s controls <br /> C403.2.12.1 Varia6le flow control- Indicate cooling tower fans requiring variable flow control and method <br /> N/A coolin towers <br /> C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and <br /> N/A coolin demand;or exce tion taken <br /> C403.2.12.2 Single zone AC systems Indicate method of cooling demand-based fan control for sys.>110,000 <br /> N/A btuh <br /> N/A C403.2.4.10 DDC system capabilities Identify all DDC system inpuVoutput control points and indicate capabiliry <br /> fo t e e o nt t <br /> Ducting Systems <br /> C403.2.7.1& Indicate all ductwork constructed and sealed per IMC,C402 leakage <br /> YE$ C403.2.7.3 Duct construction re uirements and IBC va or retarder re uirements M 1.0 <br /> YES 403.2.7.3.1- Duct pressure Identify location of low,medium and high pressure ductwork on plans <br /> classifcations M 1.0 <br /> C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans;provide <br /> N/A test test results to urisdiction when completed <br /> YE$ C403.2.7.1/ Duct insulation Indicate R-value of insulation on ductwork M 1.0 <br /> Piping Systems <br /> YES C403.2.8 Piping insulation Indicate R-value of insulation on piping M1.1 <br /> YES C403.2.8.1 P�Ping insulation exposed to Indicate method of protection from damage/degredation M 1.1 <br /> weather <br /> SIMPLE SYSTEMS <br /> Qualifying Systems <br /> C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits,does <br /> YE$ s stems not have active humidifcation or simultaneous heatin /coolin M1.0 <br /> C403.3 Qualifying 2-pipe heating Verif 2- i e heatin onl s stem does not exceed ca acit limits <br /> N/A s stems Y P P g y y P Y <br /> N/A C403.3.2 Hydronic system controls Refer to Complex Systems Seclion C403.4.3 <br /> Simple System Economizers <br /> YES C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls;note in equip M 1.0, M 1.1 <br /> sched. <br /> YES C403.3.1.1.1 Air economizer capacity Indicate modulaling OSA control capability up to 100%OSA,or exception M 1.0, M 1.1 <br /> YE$ C403.3.1.1.3 Air economizer high limit Indicate high limit shut-off control me�hod per Table C403.3.1.1.3(2) <br /> controls M 1.0 <br /> YE$ C403.1.12 Integrated air economizer Indicate capability for partial air economizer operation tor systems with M1.0 <br /> o eration ca acit >65 D00 btuh <br /> YES C403.3.1 Air economizer exceptions Indicate eligible exception(s)taken and provisions to comply with M 1.0 <br /> f COMPLEX SYSTEMS <br /> Complex System Economizers <br /> C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls;note in equip <br /> N/A sched. <br /> C403.4.1.4 Economizer heating system Verify control method of HVAC systems with economizers does not <br /> N/A impact increase building heating energy usage during normal operation <br /> N/A C403.4.1.3 Integrated economizer Indicate capability for partial economizer operation for air or water econo <br /> o eration s stems <br /> Moved Water economizer capacity Indicate water econo capable of 100%cooling capacity at 50�F db/45`F wb <br /> N�q osn <br /> C403.4.L2 Water economizer Indicate precooling coils and heat exchangers do not exceed pressure drop <br /> N/A maximum pressure drop limit <br /> N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s)taken and provisions to comply with <br /> n <br /> i � �/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.