My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5631 HIGHWAY PL 2017-07-12
>
Address Records
>
HIGHWAY PL
>
5631
>
5631 HIGHWAY PL 2017-07-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2017 3:44:46 PM
Creation date
7/12/2017 3:44:41 PM
Metadata
Fields
Template:
Address Document
Street Name
HIGHWAY PL
Street Number
5631
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POTTER P200 <br /> Plus 4 Fire Alarm Control Panel <br /> SLC Features RA-6500-4 x 40 LCD annunciator with a key pad in a locked metal <br /> enclosure <br /> The Potter/Nohmi protocol is a digital protocol with a proven design <br /> for reliability and noise immunity.The system does not require special LED-16—16 LED annunciator with common indicators in a locked <br /> cable or conductors for connection of the Signaling Line Circuit as metal enclosure <br /> long as the cable is compliant with NFPA 70 and NFPA 72.The system PSN-1000(E)—10 amp,remote intelligent power supply with 6 NACs, <br /> allows for Class A or Class 13 installations as well as"T—Taps." 21/Os and a P-Link repeater <br /> The total polling time for the protocol is about four(4)seconds which CA-6075—Class A convertor that converts the SLC,NACs and P-Link <br /> allows two polling cycles in the ANSI/UL 864 requirement of alarms connection <br /> reporting in less than ten seconds.Each loop is capable of 127 points <br /> UD-1 U00—UL listed,Dual line telephone alarm communicator <br /> with the exception of the P100 and P200. <br /> DRV-50—LED driver expander,used to connect up to 50 LEDs in a <br /> Sensor Features graphic display <br /> The sensors through the fire alarm control panel provide a real FCB-1000—Fire communication bridge,provides remote mounting of <br /> time status as to the condition of the system.The smoke detector the Ethernet connection <br /> sensitivity,heat detector temperature level and drift compensation FIB-1000—Fiber interface module,used to extend P-Link to multi- <br /> as all programmable options.The system also allows for a day/night mode fiber(2 required) <br /> mode where the panel automatically adjusts the sensitivity depending <br /> on the time of day.To assist in the reduction of false alarms,the smoke RL Y-5—Relay module,provides 5 form C relay contacts rated at 3.0 <br /> detectors also have a maintenance warning that sends a trouble signal amps 24VDC/125AC <br /> when a detector is dirty to the point that it can no longer maintain the SPG-1000—Serial parallel gateway,allows f'or the connection to a <br /> programmed sensitivity. serial or parallel printer <br /> User Interface The FIB-1000,FCB-1000 and the SPG-1000 may be installed in the <br /> stacker bracket or ordered with the optional rack mount enclosure. <br /> The fire alarm control panel has a 2 x 16 LCD display to provide <br /> information to the system status.The keypad has navigation keys Ethernet/I.P. Connection <br /> to allow manipulation of the Menu on board the panel.The panel is <br /> shipped standard with the following LEDs: The Y200 is shipped standard with an Ethernet connection.This <br /> connection is the programming port and may be connected to a building <br /> • AC Power—Green Wide Area Network(WAN)or Local Area Network(LAN).Once <br /> • Alarm—Red connected to the Internet,the panel may be selectively programmed to <br /> e-mail alarm conditions,trouble conditions,supervisory conditions,test, <br /> • <br /> Earth Fault—Amber Event History and detector status.An e-mail may be sent to the panel <br /> • Supervisory-Amber and the panel will e-mail the event history,detector status,configuration <br /> • Silenced-Amber file or server status to an authorized E-mail account.In addition, <br /> reminders may be set to send an e-mail for service,testing or other <br /> • Trouble-Amber conditions. <br /> The common buttons include a Silence,Reset,Acknowledge and Drill. In addition,the Ethernet connection is UL listed as an IP communicator. <br /> All of the buttons are accessible once the locked door is opened. The IP communicator is listed to report to the UL listed Sur-Gard 111 <br /> P-Link IP receiver.The 1P communicator replaces the traditional less reliable <br /> alarm communicator transmitter that utilized telephone lines.The IP <br /> The P200 has a proprietary communication protocol that communicates communicator is an active method of connection and communication to <br /> through a RS-485 connection to field devices.Up to thirty-one(3 1) the monitoring station. <br /> of each of the following devices may be connected to a single P-Link lines.The I.P.communicator is an active method of connection and <br /> connection.The P-Link includes the communication terminals and communication to the monitoring station. <br /> regulated 24 VDC connection for the field devices.The field devices <br /> may be any of the following: <br /> RA-6075—2 x 16 LCD annunciator with a key pad in a locked metal <br /> enclosure. <br /> Potter Electric Signal Company,LLC • St.Louis,MO ©P()TTM <br /> 800-325-3936 • www.pottersignal.com PksJ <br /> #8830034-RFV A PAGE 3 OF 4 <br /> 08/12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.