My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5631 HIGHWAY PL 2017-07-12
>
Address Records
>
HIGHWAY PL
>
5631
>
5631 HIGHWAY PL 2017-07-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2017 3:44:46 PM
Creation date
7/12/2017 3:44:41 PM
Metadata
Fields
Template:
Address Document
Street Name
HIGHWAY PL
Street Number
5631
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POTTER P200 <br /> PLUS Fire Alarm Control Panel <br /> SLC Loop Accessories <br /> The control panel may be connected with up to seventy-five(75)addressable devices or modules in any combination.The SLC is not restricted by <br /> any special wire requirements and may be wired with any wire that complies with the NEC. <br /> SLC Loop Devices <br /> Device Description <br /> PSA Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. <br /> PSHA Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent <br /> obscuration and a fixed temperature 135°Fahrenheit heat detector <br /> FHA Analog Fixed Temperature Heat Detector that is selectable from 135°F to 185°F <br /> RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the <br /> temperature increase 12-15°F in one minute <br /> DDA Addressable Duct Smoke Detector <br /> AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors <br /> AB4 4"round base that may be mounted to an electrical box and wired for connection to the above sensors <br /> AIB lsolater base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop <br /> ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the <br /> other is rated at 2 amps 240 VAC/30 VDC <br /> ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. <br /> Modules <br /> Device Description <br /> MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. <br /> APS-SA Single Action Addressable Pull Station <br /> APS-DA Dual Action Addressable Pull Station <br /> SCM4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box. <br /> DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. <br /> TRM4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. <br /> Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. <br /> MOM-4 Monitored Output Module is a power switching module that monitors the circuit that is controlled by the control panel. <br /> CIZM4 Conventional Input'Lone Module is used to connect conventional smoke detectors to the system that receive their power from the <br /> module.This module is like a conventional zone on the SLC. <br /> SCI Short Circuit lsolater interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. <br /> Potter Electric Signal Company,LLC • St.Louis,MO POTTER <br /> + <br /> 800-325-3936 • www.pottersignal.com Plus,,.. <br /> #8830034-REV A PAGE 2 OF 4 <br /> 08/12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.