Laserfiche WebLink
'EnvelopeZones <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&fZ6 over 3 stories and all R1 Revised Oct 2013 <br /> Project Info Project Address 801 Wetmore Ave - EvCC Olympus Hall HVAC Date 1/25/2016 <br /> Compliance forms For Building Department Use <br /> do not require a <br /> password to use. <br /> Instructional and Applicant Name: Michael Tagles <br /> calculating cells are Applicant Address: 1111 Fawcett Avenue, Ste 100, Tacoma WA <br /> write-protected. <br /> Applicant Phone: 253-383-3257 <br /> Project Description ❑New Building ❑Addition Q Alteration ❑ Change of Occupancy/Conditioning <br /> Compliance Path Q• Prescriptive p 0 Component Performance 0 Total Building Performance <br /> Selection required to enable forms. <br /> Occupancy Group QQ Commercial O Group R-R2&R3 over 3 stories and all R1 <br /> Selection required to enable forms. <br /> Vertical Fenestration and Total Vertical Gross Exterior <br /> Skylight Area Calculation Fenestration Above Grade %Vertical <br /> If complying via the Prescriptive path, (rough opening) divided by Wall Area times 100 equals Fenestration <br /> enter values for vertical fenestration, 0.0 0.0 X 10 0 - <br /> skylights,gross walls and roof on this <br /> ENV-SUM worksheet. If complying via <br /> the Component Performance path,enter Gross Exterior <br /> these values in the ENV-UA worksheet. Total Skylight divided by Roof Area times 100 equals %Skylight <br /> These values auto-fill from ENV-UA and <br /> are write-protected on ENV-SUM. 0.0 - 0.0 X 100 = <br /> Vertical <br /> Fenestration Area Fenestration Area <br /> Compliance <br /> Skylight Area <br /> Vertical Fenestration O 50%or more of the floor area is within a daylight zone per C402.3.1.1 <br /> Alternates 0 High Performance Fenestration U-factors and SHGC per C402.3.1.3 <br /> Compliance Method <br /> ❑Skylight area 3%or greater,VT-0.40 or greater <br /> Single Story Spaces ❑Skylight effective aperture 1%or greater,provide calculation <br /> Requiring Skylights ❑Space eligible for exception <br /> Requires a minimum of 50%of floor area to be within a skylight daylight zone for speck <br /> space types.Refer to C402.3.2 for requirements. <br /> ❑ Project has semi-heated spaces as defined per C402.1.4 <br /> ❑Applying wall exception to semi-heated spaces <br /> 1.Semi-heated spaces may comply under Prescriptive or Component Performance compliance <br /> Semi-Heated Spaces path. <br /> 2.Semi-heated spaces shall be documented separately from other conditioned spaces—provide <br /> separate compliance forms for each conditioned space type. <br /> 3.Envelope elements separating semi-heated from other conditioned spaces shall comply with <br /> exterior thermal envelope requirements. <br /> ❑Walk-in Cooler ❑ Walk-in Freezer <br /> ❑ <br /> Refrigerated Spaces Refrigerated Warehouse Cooler E] Refrigerated Warehouse Freezer <br /> Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for <br /> these areas may be combined with non-refrigerated areas in the ENV-PRESCRIPTIVE form. Refer <br /> to C402.5 and C402.6 for requirements. <br /> Project includes more than one occupancy type and/or level of space conditioning.Multiple <br /> Mixed Occupancy and/or compliance forms may be required. Select all that apply to scope of project: <br /> Space Conditioning ❑ Commercial ❑ R2&R3 over 3 stories and all R1 ❑ Refrigerated Space <br /> ❑ Fully Conditioned ❑ Semi-Heated ❑ Low Energy* <br /> ❑ R2&R3-3 stories or less <br /> *Low energy areas are exempt from all thermal envelope provisions and compliance forms for <br /> these areas are not required.Refer to C101.5.2 for exemption. <br />