My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 TOWER ST OLYMPUS HALL 2017-07-28
>
Address Records
>
TOWER ST
>
2000
>
OLYMPUS HALL
>
2000 TOWER ST OLYMPUS HALL 2017-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2017 11:48:31 AM
Creation date
7/17/2017 9:40:11 AM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
OLYMPUS HALL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'EnvelopeZones <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&fZ6 over 3 stories and all R1 Revised Oct 2013 <br /> Project Info Project Address 801 Wetmore Ave - EvCC Olympus Hall HVAC Date 1/25/2016 <br /> Compliance forms For Building Department Use <br /> do not require a <br /> password to use. <br /> Instructional and Applicant Name: Michael Tagles <br /> calculating cells are Applicant Address: 1111 Fawcett Avenue, Ste 100, Tacoma WA <br /> write-protected. <br /> Applicant Phone: 253-383-3257 <br /> Project Description ❑New Building ❑Addition Q Alteration ❑ Change of Occupancy/Conditioning <br /> Compliance Path Q• Prescriptive p 0 Component Performance 0 Total Building Performance <br /> Selection required to enable forms. <br /> Occupancy Group QQ Commercial O Group R-R2&R3 over 3 stories and all R1 <br /> Selection required to enable forms. <br /> Vertical Fenestration and Total Vertical Gross Exterior <br /> Skylight Area Calculation Fenestration Above Grade %Vertical <br /> If complying via the Prescriptive path, (rough opening) divided by Wall Area times 100 equals Fenestration <br /> enter values for vertical fenestration, 0.0 0.0 X 10 0 - <br /> skylights,gross walls and roof on this <br /> ENV-SUM worksheet. If complying via <br /> the Component Performance path,enter Gross Exterior <br /> these values in the ENV-UA worksheet. Total Skylight divided by Roof Area times 100 equals %Skylight <br /> These values auto-fill from ENV-UA and <br /> are write-protected on ENV-SUM. 0.0 - 0.0 X 100 = <br /> Vertical <br /> Fenestration Area Fenestration Area <br /> Compliance <br /> Skylight Area <br /> Vertical Fenestration O 50%or more of the floor area is within a daylight zone per C402.3.1.1 <br /> Alternates 0 High Performance Fenestration U-factors and SHGC per C402.3.1.3 <br /> Compliance Method <br /> ❑Skylight area 3%or greater,VT-0.40 or greater <br /> Single Story Spaces ❑Skylight effective aperture 1%or greater,provide calculation <br /> Requiring Skylights ❑Space eligible for exception <br /> Requires a minimum of 50%of floor area to be within a skylight daylight zone for speck <br /> space types.Refer to C402.3.2 for requirements. <br /> ❑ Project has semi-heated spaces as defined per C402.1.4 <br /> ❑Applying wall exception to semi-heated spaces <br /> 1.Semi-heated spaces may comply under Prescriptive or Component Performance compliance <br /> Semi-Heated Spaces path. <br /> 2.Semi-heated spaces shall be documented separately from other conditioned spaces—provide <br /> separate compliance forms for each conditioned space type. <br /> 3.Envelope elements separating semi-heated from other conditioned spaces shall comply with <br /> exterior thermal envelope requirements. <br /> ❑Walk-in Cooler ❑ Walk-in Freezer <br /> ❑ <br /> Refrigerated Spaces Refrigerated Warehouse Cooler E] Refrigerated Warehouse Freezer <br /> Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for <br /> these areas may be combined with non-refrigerated areas in the ENV-PRESCRIPTIVE form. Refer <br /> to C402.5 and C402.6 for requirements. <br /> Project includes more than one occupancy type and/or level of space conditioning.Multiple <br /> Mixed Occupancy and/or compliance forms may be required. Select all that apply to scope of project: <br /> Space Conditioning ❑ Commercial ❑ R2&R3 over 3 stories and all R1 ❑ Refrigerated Space <br /> ❑ Fully Conditioned ❑ Semi-Heated ❑ Low Energy* <br /> ❑ R2&R3-3 stories or less <br /> *Low energy areas are exempt from all thermal envelope provisions and compliance forms for <br /> these areas are not required.Refer to C101.5.2 for exemption. <br />
The URL can be used to link to this page
Your browser does not support the video tag.