Laserfiche WebLink
'Prescriptive ■ Zones , ENV-PRESMPTNE <br /> 2012 Washington State Energy Code Co e Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Oct 2013 <br /> Project Address 801 Wetmore Ave - EvCC Olympus Hall HVAC Date 01/25/2016 <br /> Occupancy Group *Commercial O Group R For Building Department Use <br /> Fenestration Area as%gross above-grade wall area Max.Target: 30.0% <br /> Skylight Area as%gross roof area Max.Target: 5.0% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Prescriptive compliance of envelope assemblies may be accomplished by providing insulation R-values per Table C402.2 or U-factors/F-factors <br /> per Tables C-402.1.2 and C-402.3.A single project may comply via R-values for some envelope assemblies and U-factors/F-factors for others. <br /> Note compliance method taken for each assembly in spaces provided. 777-7 <br /> Building Component U-Factor/F-Factor for Alternative <br /> R-Value for Prescriptive Compliance Prescriptive Compliance <br /> Alternate Cl U-Factor Source <br /> Continuous R-Value (Appendix A,Chapter 3 <br /> Cavity Ins. Ins.(CI) (Table C402.2 Assembly table,or approved <br /> Provide page/plan#of assembly detail and ID. R-Value R-Value Footnote F)1 U-Factor calculation method) <br /> Y <br /> ID:No new work <br /> U <br /> o ID: <br /> 0 <br /> ID: <br /> a ID: <br /> 42 <br /> $ m ID: <br /> 2 ID: <br /> ID: <br /> r ID: <br /> O ID: <br /> ID:No new work <br /> "- ID: <br /> g ID: <br /> -a ID: <br /> m_ ID: <br /> ID: <br /> ID: <br /> 'S o ID: <br /> C <br /> O a ID: <br /> U <br /> m ID: <br /> �i ID: <br /> I ID: <br /> Ca <br /> o ID: <br /> a� <br /> I D: <br /> mE2 <br /> c7 ID: <br /> N ID: <br /> m ID: <br /> o <br /> ID: <br /> LL � ID: <br /> ro <br /> E ID: <br /> i ID: <br /> Perim. Ins. Full Slab Cl <br /> R-Value R-Value F-Factor F-Factor Source <br /> -a ID:No new work <br /> a� <br /> a) m <br /> -0 = ID: <br /> ID: <br /> c <br /> o ID: <br /> � o <br /> -gm <br /> ) cu) ID: <br /> =I ID: <br /> Note 1-Calculations are required.Ratio of cross-sectional area of metal penetration through otherwise continuous insulation shall be 0.04-0.08%. <br /> Note 2-Thermal spacer blocking and liner system are required for prescriptive R-Value compliance. <br /> Note 3-Intermediate framing is required for prescriptive R-Value compliance in wood-framed wall assemblies. <br /> Note 4-Proposed non-residential building CMU walls meeting Table C402.1.2 Footnote D requirements can enter the target U-value of 0.104. <br /> Note 5-Refer to Table C402.2,Footnote E for prescriptive R-Value requirement for steel floorjoist assemblies. <br /> Note 6-Prescriptive slab-on-grade insulation shall extend from top of slab to minimum length per an approved method as defined in C402.2.6. <br />