My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 TOWER ST OLYMPUS HALL 2017-07-28
>
Address Records
>
TOWER ST
>
2000
>
OLYMPUS HALL
>
2000 TOWER ST OLYMPUS HALL 2017-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2017 11:48:31 AM
Creation date
7/17/2017 9:40:11 AM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
OLYMPUS HALL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
gEmacm <br /> 2012 Washington State Energy Code Compliance Forms for Commercial,Group R1,and>3 story R2 and R3 Revised June 2013 <br /> Project Address 801 Wetmore Ave-EvCC Olympus Hall HVAC Date 1/25/2016 <br /> The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 <br /> WSEC. NOTE:Define print area in Excel prior to printing MECH-CHK pages. <br /> Applicability Code Section Code Provision Information Required Location Building Department <br /> (yes,no,na) I I on Plans Notes <br /> COMPLEX SYSTEMS,CONTINUED <br /> Specific System Requirements <br /> y C403.4.2& Variable flow control-fans Indicate fans requiring variable flow control and method <br /> C403.2.12 MO.2 <br /> NA C403.4.2.1 VAV fan static pressure Indicate sensor locations on plans;include at least one sensor per major - <br /> sensors duct branch <br /> C403.4.2.2 VAV fan static pressure Indicate fan system static pressure setpoint based on zone requiring most <br /> NA setpoint pressure - <br /> VAV systems serving multi- Indicate supply air systems serving multiple zones that are required to be <br /> C403.4.5 VAV,method of primary air control,and zones served;note exceptions <br /> NA zones taken MO.2 <br /> y C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to MO.1 <br /> loads <br /> NA C403.4 Large capacity cooling Indicate method of multi-stage or variable control for building cooling <br /> systems system capacity>300 tons <br /> NA C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method _ <br /> y C403.4.3 Large capacity boiler Indicate multi-stage or modulating burner for single boilers>500,000 btuh <br /> systems MO.2 <br /> y C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers MO.2 <br /> C403.4.3.5 Chiller/boiler plant pump Indicate capability to automatically reduce overall plant flow and shut-off <br /> y isolation flow through chillers&boilers when not in use MO.2 <br /> C403.4.2& Variable flow control- Indicate pumps requiring variable flow control&method <br /> y C403.4.3.6 pumps MO.2 <br /> NA C403.2.12.1 Variable flow control- Indicate cooling tower fans requiring variable flow control and method _ <br /> &C403.4.4 cooling towers <br /> C403.4.3.4 Hydronic system part load reset supply water tem AND reduce flow b >50%fors stems>300,000 <br /> y controls PP y P y- y Mo.1 <br /> NA C403.4.3.2Two-pipe changeover Indicate deadband,heating/cooling mode scheduling and changeover <br /> systems temperature range <br /> NA C403.4.3.3.1 Water loop heat pump- Indicate capability of central equipment to provide min.20°F water supply <br /> deadband temp deadband between heat rejection and heat addition modes <br /> NA C403.4.3.3 Water loop heat pump- Provide heat exchanger that separates cooling tower and heat pump loop - <br /> heat rejection in Climate Zone 5 <br /> NA C403.4.3.3.3 Water loop heat pump- Indicate 2-way isolation valve on each heat pump and variable flow control - <br /> isolation fors stems with total pump power>10 h <br /> NA C403.4.6 Condenser water heat Indicate system provided to pre-heat service water and efficiency _ <br /> recovery <br /> N A C403.5 Cooler/freezer-anti-sweat Indicate w/sf&control method for walk-in cooler/freezer door anti-sweat - <br /> heaters I heaters <br /> NA C403.5/6 Cooler/freezer-evaporator Indicate motor type for evaporator and condenser fans<1 hp - <br /> a dco n rfans <br /> SERVICE WATER HEATING <br /> Service Water Systems <br /> NA C404.2 Water-heating equip min. Provide equipment schedule or complete MECH-SUM table with type, <br /> efficiency capacity,efficiency,test standard or other efficient source <br /> NA C404.3 Temperature controls Indicate temperature controls have required setpoint capability <br /> N A C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply& <br /> discharge <br /> NA C404.5 Insulation underwater Indicate R-10 insulation under tank _ <br /> heater <br /> NA C404.6 Service water piping Indicate R-value of insulation on piping;note exceptions taken <br /> insulation <br /> C404.7/8 Circulation systems and Indicate shut-off capability based on occupancy and periods of limited <br /> NA heat trace shut-off demand _ <br /> NA C404.9 Group R-2 service hot water Indicate method of usage metering for dwell.units served by central HW <br /> eters s <br /> Pools&In-Ground Permanently Installed Spas <br /> Pool heating equip min. Provide equipment schedule or complete MECH-SUM table with type, <br /> NA C404.10.1 efficiency capacity,efficiency,test standard(or other eff.source);heat pump heaters <br /> >_4 COP <br /> NA C404.10.1/2 Pool heater on/off controls Indicate automatic on/off control based on scheduling&accessible on/off <br /> switch on heater that operates independent of thermostat setting;or <br /> NA C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required _ <br /> NA C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to>90°F <br /> NA L.C404.10.4 Heat recovery Indicate method,exhaust air temperature reduction and recovered energy - <br /> us <br />
The URL can be used to link to this page
Your browser does not support the video tag.