My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1513 WALNUT ST 2017-07-28
>
Address Records
>
WALNUT ST
>
1513
>
1513 WALNUT ST 2017-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2017 3:54:26 PM
Creation date
7/17/2017 1:22:04 PM
Metadata
Fields
Template:
Address Document
Street Name
WALNUT ST
Street Number
1513
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GKBUILDING <br /> STRUCTURAL ENG/NEER/NGS LLC <br /> DEPARTMENT <br /> EFFECT/VE.EFF7C/ENT.SOLUT/ONS <br /> RE5PON5E LETTER <br /> City of Everett Public Works December 8, 2014 <br /> Attn: Meg Haley GK Project#: YR6-14-037 <br /> 3200 Cedar Street A_ . �� l_/ldj <br /> Everett, WA 98201 I` <br /> Re: Corrections Letter#2 Response for 1513 Walnut St <br /> City of Everett Permit#131409-004 <br /> Dear Ms. Haley: <br /> GK Structural Engineering,LLC(GKSE)is in receipt of the City of Everett Public Works Corrections <br /> Letter#2 dated November 6,2014 for the above referenced project. The following is a corresponding <br /> itemized response and clarification to the plan review comments. Please reference the attached <br /> supplemental drawings. <br /> General: <br /> 1. Reference the attached supplemental drawing sheets Al thru A3 depicting the existing upper <br /> floor(Unit A)and main floor(Unit B)floor plans. All existing conditions are shown as well <br /> as walls to be removed and new walls in the main floor Unit B floor plan to conform to the <br /> duplex occupancy requirements. The new Al thru A3 sheets should be reviewed in <br /> conjunction with the original drawing sheets 1 thru 4 previously submitted and regarded as <br /> one complete drawing set. <br /> 2. Reference original drawing sheets 1 thru 4 and supplemental drawing sheets A I thru A3. <br /> 3. Reference plan notes on sheet A1. <br /> 4. Reference plan notes on sheet A 1 and A2. <br /> 5. The structure is being configured such that Unit A occupies the entire upper floor area and <br /> Unit B occupies the entire main floor area. Reference attached drawing sheets AI thru A3. <br /> 6. Reference previously submitted drawing sheet I with site plan,property info and vicinity <br /> map. Also reference the attached copy of the City of Everett Public Works `Non-Conforming <br /> Building Certification' letter. <br /> Structural: <br /> 1. The original drawing sheets 1 thru 4 and structural calculations previously submitted <br /> addressed the structural concerns regarding the roof replacement portion of this project. The <br /> new pre-manufactured wood roof trusses will span from north exterior wall to south exterior <br /> wall. The original 2x4 roof rafter framing to be removed currently spans from the same north <br /> exterior wall to south exterior wall. Therefore,there is no change in load path or magnitude <br /> to the supporting framing including window and door headers from the current existing <br /> conditions. In addition,the proposed modifications to the main floor Unit B floor plan do not <br /> affect any load bearing wall elements. <br /> 2. Reference Structural response item#I above. <br /> Construction: <br /> 1. Reference the attached supplemental drawing sheets Al thru A3. Egress window sizes& <br /> locations are noted, handrail and guardrails are noted and smoke/CO detector requirements <br /> are specified. Sheet A3 shows a full building section identifying,to the best of our ability <br /> 605 STA7-E ST S, 57-E 700-0 PAGE 1 of 2 P;4Z5.Z30.9 137 <br /> KIRKLAND, WA 98033 F;4Z5.Z5O.Z3S4 /V/� <br />
The URL can be used to link to this page
Your browser does not support the video tag.