Laserfiche WebLink
1 <br /> BUILDING PLANNING <br /> illumination of 6 footcandles (65 lux) over the area 3. Clothes dryer exhaust ducts shall be terminated in I <br /> of the room at a height of 30 inches (762 mm) above accordance with Section M1502.3. <br /> the floor level. R303.5.2 Exhaust openings. Exhaust air shall not be <br /> 3. Use of sunroom and patio covers, as defined in Sec- directed onto walkways. <br /> tion R202,shall be permitted for natural ventilation if R303.6 Outside opening protection.Air exhaust and intake <br /> in excess of 40 percent of the exterior sunroom walls openings that terminate outdoors shall be protected with cor- <br /> are open,or are enclosed only by insect screening. rosion-resistant screens, louvers or grilles having an opening <br /> R303.2 Adjoining rooms. For the purpose of determining size of not less than 1/4 inch (6 mm) and a maximum opening <br /> light and ventilation requirements, any room shall be consid- size of 1/2 inch(13 mm),in any dimension. Openings shall be <br /> ered to be a portion of an adjoining room where not less than protected against local weather conditions. Outdoor air <br /> one-half of the area of the common wall is open and unob- exhaust and intake openings shall meet the provisions for <br /> structed and provides an opening of not less than one-tenth of exterior wall opening protectives in accordance with this <br /> the floor area of the interior room and not less than 25 square code. <br /> feet(2.3 m2). R303.7 Interior stairway illumination. Interior stairways <br /> Exception:Openings required for light or ventilation shall shall be provided with an artificial light source to illuminate <br /> be permitted to open into a sunroom with thermal isolation the landings and treads. The light source shall be capable of <br /> or a patio cover, provided that there is an openable area illuminating treads and landings to levels of not less than 1 <br /> between the adjoining room and the sunroom or patio foot-candle (11 lux) as measured at the center of treads and <br /> cover of not less than one-tenth of the floor area of the landings. There shall be a wall switch at each floor level to <br /> interior room and not less than 20 square feet (2 m2). The control the light source where the stairway has six or more <br /> minimum openable area to the outdoors shall be based risers. <br /> upon the total floor area being ventilated. Exception: A switch is not required where remote,central <br /> R303.3 Bathrooms. Bathrooms, water closet compartments or automatic control of lighting is provided. <br /> and other similar rooms shall be provided with aggregate gl Zz- R303.8 Exterior stairway illumination. Exterior stairways <br /> ing area in windows of not less than 3 square feet (0.3 m ), shall be provided with an artificial light source located at the <br /> one-half of which must be openable. top landing of the stairway. Exterior stairways providing <br /> Exception: The glazed areas shall not be required where access to a basement from the outdoor grade level shall be <br /> artificial light and a local exhaust system are provided. provided with an artificial light source located at the bottom <br /> The minimum local exhaust rates shall be determined in landing of the stairway. <br /> accordance with Section M1507. Exhaust air from the R303.9 Required glazed openings. Required glazed open- <br /> space shall be exhausted directly to the outdoors. ings shall open directly onto a street or public alley, or a yard <br /> R303.4 Mechanical ventilation. Where the air infiltration or court located on the same lot as the building. <br /> rate of a dwelling unit is 5 air changes per hour or less where Exceptions: <br /> tested with a blower door at a pressure of 0.2 inch w.c (50 Pa) <br /> in accordance with Section N1102.4.1.2, the dwelling unit 1. Required glazed openings that face into a roofed <br /> shall be provided with whole-house mechanical ventilation in porch where the porch abuts a street,yard or court <br /> accordance with Section M1507.3. and the longer side of the porch is not less than 65 <br /> R303.5 Opening location.Outdoor intake and exhaust open- percent unobstructed and the ceiling height is not <br /> ings shall be located in accordance with Sections R303.5.1 less than 7 feet(2134 mm). ' <br /> and R303.5.2. 2. Eave projections shall not be considered as obstruct- <br /> R303.5.1 Intake openings. Mechanical and gravity out- ing the clear open space of a yard or court. <br /> door air intake openings shall be located not less than 10 3. Required glazed openings that face into the area <br /> feet (3048 mm) from any hazardous or noxious contami- under a deck, balcony, bay or floor cantilever where <br /> nant, such as vents, chimneys, plumbing vents, streets, a clear vertical space not less than 36 inches (914 <br /> alleys,parking lots and loading docks. mm) in height is provided. <br /> For the purpose of this section, the exhaust from dwell- R303.9.1 Sunroom additions. Required glazed openings <br /> ing unit toilet rooms, bathrooms and kitchens shall not be shall be permitted to open into sunroom additions or patio <br /> considered as hazardous or noxious. covers that abut a street,yard or court if in excess of 40 <br /> percent of the exterior sunroom walls are open, or are <br /> Exceptions: enclosed only by insect screening, and the ceiling height <br /> 1. The 10-foot(3048 mm) separation is not required of the sunroom is not less than 7 feet(2134 mm). <br /> where the intake opening is located 3 feet (914 R303.10 Required heating. Where the winter design tem- <br /> mm) or greater below the contaminant source. perature in Table R301.2(1) is below 60°F (16°C), every <br /> 2. Vents and chimneys serving fuel-burning appli- dwelling unit shall be provided with heating facilities capable <br /> ances shall be terminated in accordance with the of maintaining a room temperature of not less than 68°F <br /> applicable provisions of Chapters 18 and 24. (20°C) at a point 3 feet (914 mm) above the floor and 2 feet <br /> 56 2015 INTERNATIONAL RESIDENTIAL CODE® <br />