BUILDING PLANNING <br /> 4. One thickness of 3/4 inch (19.1 mm) particleboard trical outlets, lighting, devices, luminaires, wires, speakers, <br /> with joints backed by 3/4 inch (19.1 mm) particle- drainage,piping and similar openings or penetrations shall be <br /> board. permitted. <br /> 5. One-half-inch (12.7 mm) gypsum board. Exceptions: <br /> 6. One-quarter-inch (6.4 mm) cement-based millboard. 1. Floor assemblies located directly over a space pro- <br /> 7. Batts or blankets of mineral wool or glass fiber or tected by an automatic sprinkler system in accor- <br /> other approved materials installed in such a manner dance with Section P2904, NFPA 13D, or other <br /> as to be securely retained in place. approved equivalent sprinkler system. <br /> ' 8. Cellulose insulation installed as tested in accordance 2• Floor assemblies located directly over a crawl space <br /> with ASTM E 119 or UL 263,for the specific appli- not intended for storage or fuel-fired appliances. <br /> cation. 3. Portions of floor assemblies shall be permitted to be <br /> R302.11.1.1 Batts or blankets of mineral or glass unprotected where complying with the following: <br /> fiber. Batts or blankets of mineral or glass fiber or 3.1. The aggregate area of the unprotected portions <br /> other approved nonrigid materials shall be permitted does not exceed 80 square feet(7.4 mZ)per story <br /> for compliance with the 10-foot (3048 mm) horizontal <br /> fireblocking in walls constructed using parallel rows of 3.2. Fireblocking in accordance with Section <br /> studs or staggered studs. R302.11.1 is installed along the perimeter of the <br /> unprotected portion to separate the unprotected <br /> R302.11.1.2 Unfaced fiberglass. Unfaced fiberglass portion from the remainder of the floor assem- <br /> batt insulation used as fireblocking shall fill the entire <br /> cross section of the wall cavity to a height of not less bly. <br /> than 16 inches (406 mm) measured vertically. Where 4. Wood floor assemblies using dimension lumber or <br /> piping,conduit or similar obstructions are encountered, structural composite lumber equal to or greater than <br /> the insulation shall be packed tightly around the 2-inch by 10-inch (50.8 mm by 254 mm) nominal <br /> obstruction. dimension, or other approved floor assemblies <br /> R302.11.1.3 Loose-fill insulation material.Loose-fill demonstrating equivalent fire performance. <br /> insulation material shall not be used as a fireblock R302.14 Combustible insulation clearance. Combustible <br /> unless specifically tested in the form and manner insulation shall be separated not less than 3 inches (76 mm) <br /> intended for use to demonstrate its ability to remain in from recessed luminaires, fan motors and other heat-produc- <br /> place and to retard the spread of fire and hot gases. ing devices. <br /> R302.11.2 Fireblocking integrity. The integrity of fire- Exception: Where heat-producing devices are listed for <br /> blocks shall be maintained. lesser clearances, combustible insulation complying with <br /> R302.12 Draftstopping. In combustible construction where the listing requirements shall be separated in accordance there is usable space both above and below the concealed with the conditions stipulated in the listing. <br /> space of a floor-ceiling assembly,draftstops shall be installed Recessed luminaires installed in the building thermal <br /> so that the area of the concealed space does not exceed 1,000 envelope shall meet the requirements of Section N1102.4.5 of <br /> square feet (92.9 m2). Draftstopping shall divide the con- this code. <br /> cealed space into approximately equal areas. Where the <br /> assembly is enclosed by a floor membrane above and a ceil- <br /> ing membrane below, draftstopping shall be provided in SECTION R303 <br /> floor-ceiling assemblies under the following circumstances: LIGHT,VENTILATION AND HEATING <br /> 1. Ceiling is suspended under the floor framing. R303.1 Habitable rooms. Habitable rooms shall have an <br /> 2. Floor framing is constructed of truss-type open-web or aggregate glazing area of not less than 8 percent of the floor <br /> perforated members. area of such rooms.Natural ventilation shall be through win- <br /> dows,skylights,doors,louvers or other approved openings to <br /> R302.12.1 Materials.Draftstopping materials shall be not the outdoor air. Such openings shall be provided with ready <br /> less than '/,-inch (12.7 mm) gypsum board, '/,-inch (9.5 access or shall otherwise be readily controllable by the build- <br /> mm) wood structural panels or other approved materials ing occupants. The openable area to the outdoors shall be not <br /> adequately supported.Draftstopping shall be installed par- less than 4 percent of the floor area being ventilated. <br /> allel to the floor framing members unless otherwise Exceptions: <br /> approved by the building official. The integrity of the <br /> draftstops shall be maintained. 1. The glazed areas need not be openable where the <br /> *k R302.13 Fire protection of floors.Floor assemblies that are opening is not required by Section R310 and a <br /> not required elsewhere in this code to be fire-resistance rated, whole-house mechanical ventilation system is <br /> shall be provided with a '/,-inch (12.7 mm) gypsum wall- installed in accordance with Section M1507. <br /> board membrane, '/,-inch (16 mm) wood structural panel 2. The glazed areas need not be installed in rooms <br /> Imembrane, or equivalent on the underside of the floor fram- where Exception 1 is satisfied and artificial light is <br /> ing member. Penetrations or openings for ducts, vents, elec- provided that is capable of producing an average <br /> 2015 INTERNATIONAL RESIDENTIAL CODE 55 <br />