TABLE C407.5.1(4) <br /> SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS <br /> ° SYSTEM <br /> NO. SYSTEM TYPE FAN CONTROL COOLING TYPE HEATING TYPE <br /> I Variable air volume with parallel fan-powered VAV Chilled water' Electric resistance <br /> boxes' <br /> 2 Variable air volume with reheath VAVd Chilled water' Hot water fossil fuel <br /> boilerf <br /> 3 Packaged variable air volume with parallel VAVd Direct expansion' Electric resistance <br /> fan-powered boxeSa <br /> 4 Packaged variable air volume with reheatb VAVd Direct expansion' Hot water fossil fuel <br /> boiler <br /> 5 Two-pipe fan coil Constant volume Chilled water' Electric resistance <br /> 6 Water-source heat pump Constant volume', Direct expansion' Electric heat pump and <br /> boilers <br /> 7k Four-pipe fan coil Constant volume'j Chilled water' Hot water fossil fuel <br /> boilerf <br /> 8k Packaged terminal heat pump Constant volume'•] Direct expansion' Electric heat pump <br /> 9k Packaged rooftop heat pump Constant volume'' Direct expansion' Electric heat pump <br /> h <br /> lok Packaged terminal air conditioner Constant volume'•] Direct expansion Hot water fossil fuel <br /> boilerf <br /> Ilk Packaged rooftop air conditioner Constant volume'' I Direct expansion Fossil fuel furnace <br /> ■ <br /> For SI: 1 foot=304.8 mm,1 cfm/ftz=0.0004719,1 Btu/h=0.293/W,'C=[('F)-32/1.8]. <br /> a. VAV with parallel boxes:Fans in parallel VAV fan-powered boxes shall be sized for 50 percent of the peak design flow rate and shall be <br /> 0 modeled with 0.35 W/cfm fan power.Minimum volume setpoints for fan-powered boxes shall be equal to the minimum rate for the space <br /> required for ventilation consistent with Section C403.4.4,Exception 4.Supply air temperature shall be reset based on zone demand.Design <br /> C airflow rates shall be sized for the maximum reset supply air temperature.The air temperature for cooling shall be reset higher by 5'F under the <br /> C minimum cooling load conditions. <br /> b. VAV with reheat:Minimum volume setpoints for VAV reheat boxes shall be 0.4 cfm/ft2 of floor area.Supply air temperature shall be reset <br /> ° based on zone demand.Design airflow rates shall be sized for the maximum reset supply air temperature.The air temperature for cooling shall be <br /> '1 reset higher by 5°F under the minimum cooling conditions. <br /> o� <br /> C. Direct expansion:The fuel type for the cooling system shall match that of the cooling system in the proposed design. <br /> d. VAV:When the proposed design system has a supply,return or relief fan motor horsepower(hp)requiring variable flow controls as required by <br /> Section C403.2.11.5,the corresponding fan in the VAV system of the standard reference design shall be modeled assuming a variable speed <br /> drive.For smaller fans,a forward-curved centrifugal fan with inlet vanes shall be modeled.If the proposed design's system has a direct digital <br /> control system at the zone level,static pressure setpoint reset based on zone requirements in accordance with Section C403.4.I shall be modeled. <br /> ° e. Chilled water:For systems using purchased chilled water,the chillers are not explicitly modeled.Otherwise,the standard reference design's <br /> chiller plant shall be modeled with chillers having the number as indicated in Table C407.5.1(5)as a function of standard reference building <br /> chiller plant load and type as indicated in Table C407.5.1(6)as a function of individual chiller load.Where chiller fuel source is mixed,the system <br /> in the standard reference design shall have chillers with the same fuel types and with capacities having the same proportional capacity as the <br /> proposed design's chillers for each fuel type.Chilled water supply temperature shall be modeled at 44'F design supply temperature and 56°F <br /> return temperature.Piping losses shall not be modeled in either building model.Chilled water supply water temperature shall be reset in <br /> accordance with Section C403.4.2.4.Pump system power for each pumping system shall be the same as the proposed design;if the proposed <br /> design has no chilled water pumps,the standard reference design pump power shall be 22 W/gpm(equal to a pump operating against a 75-foot <br /> head,65-percent combined impeller and motor efficiency).The chilled water system shall be modeled as primary-only variable flow with flow <br /> maintained at the design rate through each chiller using a bypass.Chilled water pumps shall be modeled as riding the pump curve or with <br /> variable-speed drives when required in Section C403.4.2.4.The heat rejection device shall be an axial fan cooling tower with variable speed fans <br /> if required in Section C403.4.3.Condenser water design supply temperature shall be 85°F or 10°F approach to design wet-bulb temperature, <br /> C whichever is lower,with a design temperature rise of 10'F.The tower shall be controlled to maintain a 70'F leaving water temperature where <br /> weather permits,floating up to leaving water temperature at design conditions.Pump system power for each pumping system shall be the same as <br /> 1 the proposed design;if the proposed design has no condenser water pumps,the standard reference design pump power shall be 19 W/gpm(equal <br /> to a pump operating against a 60-foot head,60-percent combined impeller and motor efficiency).Each chiller shall be modeled with separate <br /> condenser water and chilled water pumps interlocked to operate with the associated chiller. <br /> f. Fossil fuel boiler:For systems using purchased hot water or steam,the boilers are not explicitly modeled.Otherwise,the boiler plant shall use the <br /> same fuel as the proposed design and shall be natural draft.The standard reference design boiler plant shall be modeled with a single boiler if the <br /> standard reference design plant load is 600,000 Btu/h and less and with two equally sized boilers for plant capacities exceeding 600,000 Btu/h. <br /> Boilers shall be staged as required by the load.Hot water supply temperature shall be modeled at 1807 design supply temperature and 130°F <br /> return temperature.Piping losses shall not be modeled in either building model.Hot water supply water temperature shall be reset in accordance <br /> with Section C403.4.2.4.Pump system power for each pumping system shall be the same as the proposed design;if the proposed design has no <br /> hot water pumps,the standard reference design pump power shall be 19 W/gpm(equal to a pump operating against a 60-foot head,60-percent <br /> combined impeller and motor efficiency).The hot water system shall be modeled as primary only with continuous variable flow.Hot water <br /> pumps shall be modeled as riding the pump curve or with variable speed drives when required by Section C403.4.2.4. <br /> CE-104 2015 Washington State Energy Code <br />
The URL can be used to link to this page
Your browser does not support the video tag.