Laserfiche WebLink
Option Cards <br /> EDWARDS iO Series panels are supported by a complete line RZI16-2 Remote Zone Interface Module <br /> of modules and related equipment that enhance performance I-W <br /> and extend system capabilities.Option cards plug directly into <br /> the control panel main circuit board or are connected to it with a <br /> ribbon cable.After installation,terminals remain accessible.The - <br /> cabinet provides ample room for wire routing,keeping wiring neat <br /> at all times. <br /> f� <br /> Single and Dual Loop Controller Cards The RZI16-2 Addressable Remote Zone Interface Module is an <br /> The iO-SDC1 is a single loop controller card that can be used with addressable device that provides connections for sixteen Class B <br /> the i064 as a replacement for the standard 64-point loop,or with Initiating Device Circuits and two Class B Supervised Output <br /> the i01000 as a 250-point expansion module. Circuits.The inputs and outputs can be configured individually for <br /> The iO-SDC2 is a 500-point dual loop controller card for the several device types. <br /> iO1000 that provides two SLC circuits, each with 125 detector It requires 18 consecutive addresses on the Signaling Line Circuit <br /> addresses and 125 module addresses. (SLC).Addresses are assigned electronically.There are no address <br /> Specifications i0-SDC1 iO-SDC2 switches to set. <br /> Device Addresses i01000:one loop,250 i01000:two loops, The RZI16-2 incorporates two 8-segment DIP switches that are <br /> device addresses 500 device addresses used to select the Alarm or Supervisory default device type for <br /> i064:64 addresses each of the 16 IDC circuits.The module also includes one 4-seg- <br /> Wiring Class B or Class A ment DIP switch used to select the default Relay or NAC output <br /> Operating Voltage 24 VDC device type. Device types other than the default are accomplished <br /> Operating Current Standby:55 mA Standby:45 mA through programming. <br /> (fully loaded loop) Alarm:80 mA Alarm:70 mA <br /> Note:These ratings do not include the use of two-wire smoke modules. <br /> RZI16-2 Specifications <br /> m <br /> Communication Line Max.20.6 V peak-to-peak Voltage <br /> Voltage 24V/Aux nominal: 24 VDC <br /> Terminal Rating 12 to 18 AWG(0.75 to 2.5 mmg Supervisory current: 250 mA at 24 VDC nominalAlarm Current 1000 mA <br /> Circuit Current 0.5 A max. 24V/Aux minimum: 18.4 VDC <br /> Max total loop 66 f) 24V/Aux maximum: 26.4 VDC <br /> resistance NAC1,NAC2 nominal: 24 VDC <br /> Max total loop 0.5 pF Current <br /> capacitance Standby current <br /> Isolators 64 isolators maximum per loop(total both for 4.7 k EOL(U.S.) 4.8 mA/circuit <br /> isolator bases and modules) Standby current for <br /> Ground Fault 0 to 5 kQ 3.9 k EOL(Canada) 5.7 mA/circuit <br /> Impedance Alarm current <br /> Operating 32 to 120°F(0 to 49°C) at nominal voltage 31.1 nrA/circuit <br /> Environment 0 to 93%noncondensing at 90°F(32°C) Relay outputs <br /> Quantity 2 <br /> Type Rating(pilot duty) Programmable 24 VDC at 2.5 A <br /> Input circuit wiring 25 Q per wire <br /> SA-ETH Ethernet Interface Card resistance <br /> SA-ETH wiring The SA-ETH card provides a Initiating device circuits <br /> etAork <br /> New,ork cable—& ro` on standard 10/100 Base T Ether- Quantity 16 <br /> NeUnork ca 61e connnecec tion <br /> net network connection for EOL resistor 4.7 kQ(U.S.);3.9 kQ Canada <br /> connecting to an intranet, a local Zone voltage 22.78 V for 4.7 kQ(U.S.) <br /> I network, or the Internet.The 22.08 V for 3.9 kQ(Canada) <br /> + card can be used to download Alarm current 31.1 mA/channel at nominal voltage <br /> Alarm impedance range <680 Q <br /> a configuration programming from Trouble impedance range >5.55 kQ <br /> the iO-CU to the panel. Supervised output circuits <br /> The Ethernet card is installed on EOL resistor 15 kQ <br /> ® the plastic assembly and con- Quantity 2 <br /> � Short circuit detection <2.6 kQ <br /> nects to the main circuit board Open circuit detection >61.9 kQ <br /> Ethemetcard via a ribbon cable. Contact ratings 24 VDC at 2.5 A(5 A for two NACs) <br /> SA-ETH specifications Compatible cabinets MFC(A),i01000,APS <br /> Ethernet 10/100 Base T <br /> Operating environment <br /> Temperature 32 to 120°F(0 to 49°C) <br /> Humidity 0 to 93%RH,noncondensing at 90°F <br /> (32°C) <br /> Page 5 of 8 E85001 -0135 <br /> Issue 1.1 <br />