Laserfiche WebLink
- Section �� <br /> # Final Inspection Complies? I Comments/Assumptions <br /> C403.2.4. Heating and cooling to each zone is ❑Complies <br /> 1 controlled by a thermostat control. ❑Does Not <br /> [F147]3 Minimum one humidity control device <br /> ❑Not Observable <br /> per installed ' <br /> humidification/dehumidification ❑Not Applicable <br /> system. <br /> C403.2.4. Thermostatic controls have a 5 °F []Complies <br /> 2 deadband. i❑Does Not <br /> [FI38]3 ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.4. Temperature controls have setpoint ❑Complies <br /> 2 overlap restrictions. ❑Does Not <br /> [F[20]3 ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.4. Each zone equipped with setback ❑Complies <br /> 3 controls using automatic time clock or ❑Does Not <br /> [FI39]3 programmable control system. <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.4. Automatic Controls:Setback to 55°F ❑Complies <br /> 3 (heat)and 85°F(cool); 7-day clock, 2- ❑Does Not <br /> [F140]3 hour occupant override, 10-hour <br /> backup ❑Not Observable',. <br /> ❑Not Applicable <br /> C403.2.4. Systems include optimum start ❑Complies <br /> 3.3 controls. ❑Does Not <br /> [F141]3 ❑Not Observable <br /> ❑Not Applicable <br /> C408.2.5. Furnished HVAC as-built drawings ;❑Complies <br /> 1 submitted within 90 days of system '❑Does Not <br /> [F17]3 acceptance. <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C303.3, Furnished O&M manuals for HVAC ,❑Complies <br /> C408.2.5. systems within 90 days of system '❑Does Not <br /> 3 acceptance. <br /> ❑ <br /> [F18]3 Not Observable <br /> []Not Applicable <br /> C408.2.5. An air and/or hydronic system ❑Complies <br /> 3 balancing report is provided for HVAC ❑Does Not <br /> [F143]1 systems. ❑Not Observable', <br /> ❑Not Applicable <br /> C408.2.3. HVAC control systems have been ❑Complies <br /> 2 tested to ensure proper operation, ❑Does Not <br /> [F110]1 calibration and adjustment of controls. <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C404.3 Public lavatory faucet water ❑Complies <br /> [FI 11]3 temperature<=110°F. ❑Does Not <br /> [-]Not Observable <br /> ❑Not Applicable <br /> C404.5 First 8 ft of outlet piping is insulated ❑Complies <br /> [F145]2 ❑Does Not <br /> ❑Not Observable <br /> ❑Not Applicable <br /> 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) <br /> Project Title: UBS- EVERETT Report date: /1 <br /> Data filename: \\Cdpepc-fs-1\projects\UBS-\EVERETT,WA\PROJECT UBS-1172 1604 Hewitt Avenue, 6th Fir, Page 7 of 9 <br /> Everett, WA\PROJECT INFORMATION\Com Check\LTG 2012.cck <br />