semi-jagged to jagged edges and no paint along the inside surfaces. There was no evidence of any significant movement <br /> or racking due to the tree strike as would be indicated by new door trim joint gaps or additional GWB or GCB damage <br /> above the door. <br /> Regarding repairs, the GCB and original 1x4 tongue-and-groove bead board ceiling finishes will need to be removed to <br /> expose (2) rafter bays so the repairs can be completed. There is no interior attic access and the only access is through a <br /> gable end vent at the north side of the attic. The damaged rafter ties can be replaced by a 2x4 collar tie and 2x4 vertical <br /> brace, both fastened to the existing rafter using a minimum of(4) 0.1480 p-nails. The vertical brace can be installed at <br /> the opposite side of the collar tie to avoid nail congestion and the vertical brace shall be fastened to the existing ceiling <br /> joist using a minimum of(2) 0.148x3 p-nails. <br /> 3/" PWD sheathing should be installed to replace the damaged skip board sheathing over the 3rd and 4th rafters, with <br /> minimum nailing per code, with matching OSB installed over the PWD to match. W PWD sheathing should also be <br /> installed to replace the damaged bead board ceiling finishes. The original bead board ceiling finishes help strengthen <br /> the 2x4 ceiling joists and allow them to span over the length of the family room without any significant sagging or <br /> deflection. %" PWD should also be installed to replace the damaged shiplap sheathing at the main floor, between the <br /> (2) adjacent floor joists each side of the impact damage location. <br /> The diagonal GWB cracks above the west side of the master bedroom door can be repaired by isolated replacement of <br /> the GWB, with texture and paint to match. Cosmetic repairs could be attempted, but if not done properly the cracks will <br /> likely return. <br /> A damage inspection permit is required so the City of Everett can verify extent of damage to determine permit submittal <br /> requirements. Permit submittal requirements will likely include an over-the-counter permit in lieu of repair plans. BCIE <br /> can assist with the permit process or provide repair details to assist the contractor. <br /> Let me know if I can be of further assistance and if this email is sufficient in lieu of a written report. Thanks, <br /> Jesse Binford, PE, Principal <br /> INVESTIGATIVE <br /> ENGINEERS, LLC <br /> RiSiIUNSI V E + AC CUHA. ( E + 1 10 0 11 11 L! G-1 <br /> 3605 C Street NE, Auburn, WA. 98002 <br /> 253-670-9513 (c) 253-833-5557 (o) <br /> ***** PLEASE NOTE ***** This E-Mail/telefax message and any documents accompanying this <br /> transmission may contain privileged and/or confidential information and is intended solely for the addressee(s) <br /> named above. If you are not the intended addressee/recipient, you are hereby notified that any use of, <br /> disclosure, copying, distribution, or reliance on the contents of this E-Mail/telefax information is strictly <br /> prohibited and may result in legal action against you. Please reply to the sender advising of the error in <br /> transmission and immediately delete/destroy the message and any accompanying documents. Thank you.***** <br /> 8i/� <br />