My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6201 ASSOCIATED BLVD JDS INC 2018-03-29
>
Address Records
>
ASSOCIATED BLVD
>
6201
>
JDS INC
>
6201 ASSOCIATED BLVD JDS INC 2018-03-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2018 1:19:46 PM
Creation date
8/17/2017 8:51:15 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6201
Tenant Name
JDS INC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Energy Code Compliance Forms for Commercial,R2 and R3 over 3 stories and all R1 -Page 4 of 7 <br /> ■ <br /> MINA <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: JOS T.I. Dale 2/2/2017 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Code Section Code Provision Location in Building Department <br /> { es,no,na) Information Required-Must be in <br /> Documents Notes <br /> For supply and return ductwork located in unconditioned space or outdoors,indicate R-value <br /> of insulation on ductwork on plans;identify climate zone;note exceptions taken M-C <br /> 0403.2.8.1 For supply ductwork located in conditioned space,identify if design supply temperature is< <br /> Yes C403.2.8.2 Duct insulation 55°F or>105'F and indicate R-value of insulation on this ductwork on plans:note exception <br /> taken M-C <br /> - -----------,---,------ <br /> ------ -----_----....-------...__.... ------------ <br /> For OSA ductwork,shafts and--plenums-,indicate R-value of inautati_on_on these elements on <br /> fans er Table C402.1.3 for steel-framed walls;note exception taken M-C <br /> Piping Systems <br /> NA 0403.2.9 Piping insulation Indicate design temperature range of fluid conveyed in piping and thickness of insulation(in <br /> inches)on hydronic piping plans;or exception taken <br /> NA 0403.2.9.1 Piping insulation exposed to Indicate method of protection of pipe insulation from damage/degradation on hydronic piping <br /> weather fans <br /> Economizers <br /> Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring <br /> air economizer controls M-C <br /> _.-......--_QH"-_-- ----------------._-g--s_i ------------------------------_....--'--- -- <br /> es 0403.3 Air economizer squired Provide MECH-ECONO form indicafing systems utilizing air economizer exceptions,including <br /> those with water-side economizer in lieu of air economizer;indicate on plans eligible <br /> exception(s)taken and measures to comply with exception(s) <br /> Yes C403.3.1 Integrated economizer Indicate air and water-side economizers are configured for partial cooling operation even <br /> operation-air and water where additional mechanical cooling is required to meet the load M-C <br /> Yes C403.3.2 Economizer heating system Verify control method of HVAC systems with economizers does not increase building heating <br /> impact-air and water energy usage during normal operation M-C <br /> Yes 0403-3.3.1 Air economizer capacity Indicate modulating OSA and return air dampers are configured to provide up to 100%OSA <br /> for cooling M-C <br /> Verify mechanical cooling controls are interlocked with air economizer controls so the outside <br /> C403.3.1 air damper remains in 100%open position when mechanical cooling is also required to meet <br /> Yes Integrated air economizer the cooling load,until the leaving air temperature is<45°F M-C <br /> C403.3.3.2 __._. --- -- -- ---- -- -----------_----- --- -._.. --- __ <br /> For systems with cooling capacity a 65,000 Btu/h,verify that control of economizer dampers is <br /> not based only on mixed air temperature;or exception taken M-C <br /> Yes C403.3.3.3 Air economizer high limit Indicate high limit shut-off control method and required high limit <br /> controls q 9 per Table 0403.3.3.3 M-C <br /> For eligible systems where water-side economizer may be provided in lieu of air economizer, <br /> NA C403.3.4.1 Water economizer capacity indicate system is capable of 100%design coaling capacity at 50'F db/45'F wb OSA <br /> temperatures <br /> NA C403.3.4.2Water economizer Indicate pressure drop across precooling coils and heat exchangers in water economizer <br /> maximum pressure drop system do not exceed pressure drop limit <br /> NA C403.3.1 DX air handling equipment For DX air handlers with economizer and cooling capacity->55,000 Btu/h,refer to HVAC <br /> control System Controls for requirements <br /> DX equipment economizer For DX air handlers with economizer and cooling capacity 2 54,000 Btulh,provide a fault <br /> NA C403.2.4.7 fault detection and detection and diagnostics(FDD)system to monitor economizer system operation and report <br /> diagnostics faults <br /> Systems Requiring Energy Recovery <br /> For systems with design OSA>5,000 cfm,or design supply air cfm and%OSA exceeding the <br /> values in Tables C403.5.1(1)or(2),indicate exhaust air ER method;or exception taken with <br /> Energy recovery(ER)- supporting calculations <br /> NA C403.5.1 ventilation/exhaust For rooms served by multiple systems with aggregate design OSA>5,000 ctm,or aggregate <br /> systems design supply air cfm and%OSA exceeding the values in Tables C403.5,1(1)or(2),indicate <br /> exhaust air ER method;or exception taken with supporting calculations <br /> calculations <br /> ndcat—e—R—teefra -f-ec-v-nessthatincrea-se-s'-O-SA—en—thal-p-yby a5_0.% <br /> based._.o.-n-delta —- <br /> between OSA and return air enthalpies at design conditions <br /> Laboratory exhaust systems For buildings with total lab exhaust>5,000 cfm,indicate method of energy recovery used to <br /> NA 0403.2.7.2 pre-condition laboratory make-up air:ER effectiveness(min 25°F);or alternative method <br /> (energy recovery) Per <br /> exception(VAV exhaust,semi-conditioned makeup,or GERM calculation) <br /> For buildings with pools or spas with water surface area>200 sf,indicate exhaust air ER <br /> C404.10.4 Pools and permanent spas method and use of waste heat(preheat ventilation air,pool water or service hot water);or <br /> LNA (under exhaust systems exception taken <br /> 404.11) (energy recovery) Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air <br /> temperature at design conditions by a 36'F <br /> Energy recovery- For buildings with on-site steam heating systems,indicate condensate water ER <br /> NA0403.5.2 ---- —�-----------.___--------------------- --•---------- <br /> Y For <br /> source, <br /> I s t g _------ <br /> _ <br /> steam condensates stems ng hat use off-site generated steam where condensate is not retumed to the <br /> source,indicate on-site condensate water ER <br /> t ,A� <br /> _J <br />
The URL can be used to link to this page
Your browser does not support the video tag.