My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Faber Construction 8/14/2017
>
Contracts
>
Capital Contract
>
Faber Construction 8/14/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2018 9:05:25 AM
Creation date
8/18/2017 11:15:51 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Faber Construction
Approval Date
8/14/2017
Council Approval Date
7/27/2017
Department
Public Works
Department Project Manager
David Voigt
Subject / Project Title
Sewer Regulators R4 & R39 Modification
Public Works WO Number
UP3633
Tracking Number
0000808
Total Compensation
$1,098,104.63
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
FABER CONSTRUCTION 4/8/2018 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF EVERETT SPECIAL PROVISIONS <br /> i <br /> designs utilized that include RAP will be completed without the <br /> inclusion of the RAP. <br /> At or prior to the preconstruction meeting, the contractor shall provide <br /> one of the following mix design verification certifications for Contracting <br /> Agency review; <br /> 1. The proposed mix design indicated on a WSDOT mix <br /> design/anti-strip report that is within one year of the approval <br /> date <br /> 2. The proposed HMA mix design submittal (Form 350-042) with <br /> the seal and certification (stamp & signature) of a valid licensed <br /> Washington State Professional Engineer. <br /> 3. The proposed mix design by a qualified City or County laboratory <br /> mix design report that is within one year of the approval date. <br /> The mix design will be performed by a lab accredited by a national <br /> authority such as Laboratory Accreditation Bureau, L-A-B for <br /> Construction Materials Testing, The Construction Materials Engineering <br /> Council (CMEC's) ISO 17025 or AASHTO Accreditation Program (AAP) <br /> and shall supply evidence of participation in the AASHTO Material <br /> Reference Laboratory (AMRL) program. <br /> At the discretion of the Engineer, agencies may accept mix designs <br /> verified beyond the one year verification period with a certification from <br /> the Contractor that the materials and sources are the same as those <br /> shown on the original mix design. <br /> Evaluation of anti-strip additives are to be provided as part of the mix <br /> design acceptance criteria. Acceptable anti-strip evaluations include 1.) <br /> a WSDOT validated mix design showing the validated anti-strip additive <br /> and dosage 2.) an historic anti-strip determination from WSDOT not <br /> greater than two (2) calendar years old or 3.) a passing TSR test at the <br /> anti-strip dosage proposed by the Contractor. <br /> No paving shall begin prior to Contracting Agency approval of the 1 <br /> Contractor provided mix design. <br /> 5-04.3(7)A3 Field Verification Testing Process <br /> The City will collect three Production Samples of HMA on the first day of <br /> paving per AASHTO T 168 sampling procedures. <br /> a. The City will test one Production Sample in accordance with 5- <br /> 04.3(8)A for field verification per the requirements of 9-03.8(7). <br /> b. If the test results from the first Production Sample are within the <br /> tolerances of 9-03.8(7), the mix design will be considered verified <br /> and the test results will be used as acceptance sample number one. <br /> c. If the test results from the first Production Sample are outside the <br /> tolerances of 9-03.8(7), the other two samples will be tested and the ' <br /> results of all three tests will be used for acceptance in accordance <br /> with 5-04.5(1) and will be used in the calculation of the CPF the <br /> maximum CPF shall be 1.00. <br /> Prior to the first day of paving, six Ignition Furnace Calibration Samples shall <br /> be obtained to calibrate the Ignition Furnaces used for acceptance testing of <br /> the HMA. Calibration samples shall be provided by the Contractor when <br /> Sewer Regulators R4 and Division 5—SURFACE TREATMENTS AND PAVEMENTS May 2017 <br /> R39 Modifications <br /> WO No.—UP3633 SP-148 <br />
The URL can be used to link to this page
Your browser does not support the video tag.