ICITY OF EVERETT SPECIAL PROVISIONS <br /> directed by the Engineer. Calibration samples shall be prepared in <br /> accordance with WSDOT SOP 728. <br /> 1 5-04.3(8) Mixing <br /> 5-04.3(8)A Acceptance Sampling and Testing — HMA Mixture <br /> I 5-04.3(8)A1 General <br /> Delete all paragraphs of 5-04.3(8)A1 and substitute the following: <br /> Acceptance of HMA shall be as defined under nonstatistical or <br /> Icommercial evaluation. <br /> Nonstatistical evaluation will be used for all HMA not designated as <br /> Commercial HMA in the contract documents. <br /> IThe mix design will be the initial JMF for the class of HMA. The <br /> Contractor may request a change in the JMF. Any adjustments to the <br /> JMF will require the approval of the Project Engineer and must be made <br /> Iin accordance with Section 9-03.8(7). <br /> Commercial evaluation may be used for Commercial HMA and for other <br /> classes of HMA in the following applications: sidewalks, road <br /> approaches, ditches, slopes, paths, trails, gores, prelevel, and pavement <br /> repair. Other nonstructural applications of HMA accepted by commercial <br /> evaluation shall be as approved by the Project Engineer. Sampling and <br /> I testing of HMA accepted by commercial evaluation will be at the option of <br /> the Project Engineer. Commercial HMA can be accepted by a contractor <br /> certificate of compliance letter stating the material meets the HMA <br /> I requirements defined in the contract. <br /> 5-04.3(8)A4 Definition of Sampling Lot and Sublot <br /> Supplement 5-04.3(8)A4 with the following: <br /> IFor HMA in a structural application, sampling and testing for total project <br /> quantities less than 400 tons is at the discretion of the City Inspector. For <br /> HMA used in a structural application and with a total project quantity less <br /> I than 800 tons but more than 400 tons, a minimum of one acceptance test <br /> shall be performed: <br /> 1. If test results are found to be within specification requirements, <br /> Iadditional testing will be at the City Inspector's discretion. <br /> 2. If test results are found not to be within specification <br /> requirements, additional testing as needed to determine a CPF <br /> Ishall be performed. <br /> 5-04.3(8)A5 Test Results <br /> Delete the first paragraph of 5.04.3(8)A5. <br /> 5-04.3(8)A6 Test Methods <br /> I Delete 5-04.3(8)A6 and replace it with the following; <br /> 5-04.3(8)A6 Test Methods <br /> Testing of HMA for compliance of Va will be at the option of the City. <br /> 111 If tested, compliance of Va will be use WSDOT Standard Operating <br /> Procedure SOP 731. Testing for compliance of asphalt binder <br /> content will be by WSDOT FOP for AASHTO T 308. Testing for <br /> I <br /> Sewer Regulators R4 and Division 5—SURFACE TREATMENTS AND PAVEMENTS May 2017 <br /> I R39 Modifications <br /> WO No.—UP3633 SP-149 <br />