My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Faber Construction 8/14/2017
>
Contracts
>
Capital Contract
>
Faber Construction 8/14/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2018 9:05:25 AM
Creation date
8/18/2017 11:15:51 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Faber Construction
Approval Date
8/14/2017
Council Approval Date
7/27/2017
Department
Public Works
Department Project Manager
David Voigt
Subject / Project Title
Sewer Regulators R4 & R39 Modification
Public Works WO Number
UP3633
Tracking Number
0000808
Total Compensation
$1,098,104.63
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
FABER CONSTRUCTION 4/8/2018 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' CITY OF EVERETT SPECIAL PROVISIONS <br /> ' mechanical or electrical failure of the dewatering system shall be Contractor's <br /> responsibility to repair at no cost to the City. <br /> ' 7-08.3(2)A Survey Line and Grade <br /> Delete both paragraphs of 7-08.3(2)A and substitute the following: <br /> Provide surveys required to construct the sewer line including, but not limited <br /> ' to, alignment stakes, offset stakes, grade hubs, and intermediate staking. <br /> Use main survey control points shown on the Plans, unless Engineer directs <br /> otherwise. If a Bid item for "Surveying" is not listed in the Proposal, then this <br /> ' item shall be included with the Work with no direct compensation made. <br /> Provide laser control equipment approved by the Engineer for setting pipe <br /> grades. <br /> ' 7-08.3(2)H Sewer Line Connections <br /> Supplement 7-08.3(2)H by adding the following: <br /> Reconnect existing storm drain lines to new sanitary sewer line in accordance <br /> ' with the Plans, these Special Provisions and the Standard Specifications. <br /> Provide a minimum 8-inch diameter pipe for new storm drain line. Provide <br /> manufactured couplers for joining dissimilar size and type of existing storm <br /> ' drain line pipe. <br /> Engineer will not allow vertical connections of drain lines to sewer main <br /> ' between manholes without Engineer's prior approval. <br /> Reconnecting drain lines shall be included with the Work with no direct <br /> compensation made. <br /> ' 7-08.3(3) Backfilling <br /> Delete the first paragraph of 7-08.3(3) and substitute the following: <br /> Perform trench backfilling only after inspection and approval of the installed pipe <br /> ' bedding zone backfill. Refer to COE Standard Drawing No. 614, 615, 620 and the <br /> Plans for typical trench section backfill and compaction requirements. <br /> If the Engineer determines native material is not suitable for use as trench backfill, <br /> use "Gravel Borrow" conforming to 9-03.14(1) of the Standard Specifications. <br /> If there is an excess of suitable backfill material obtained from trench excavation <br /> at one location on the project, use it at other locations on the project or dispose of <br /> ' at an approved disposal site. The cost of transporting the excess backfill material <br /> is considered incidental to the Contract with no direct compensation made. <br /> Use Controlled Density Fill in lieu of select trench backfill for fill above pipe zone <br /> at street crossings and as directed by the Engineer in other areas where in order <br /> to prevent pavement patch settlement requires high density backfill placement or <br /> effective backfill compaction is not possible. Intersections with alleys are not <br /> ' considered street crossings. <br /> 7-08.3(4) Plugging Existing Pipe <br /> Delete the first paragraph of 7-08.3(4) and substitute the following: <br /> tWhere shown on the plans to plug and seal existing water main, sanitary sewer <br /> and storm drainage pipe plug existing pipe a minimum distance of 2-feet from the <br /> inlet end with cement grout and abandon in place. <br /> 7-08.4 Measurement <br /> Delete all paragraphs in 7-08.4 and substitute the following: <br /> Sewer Regulators R4 and Division 7—STORM, SEWER,WATER May 2017 <br /> R39 Modifications <br /> WO No.—UP3633 SP- 161 <br />
The URL can be used to link to this page
Your browser does not support the video tag.