Faber Construction 8/14/2017
>
Contracts
>
Capital Contract
>
Faber Construction 8/14/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2018 9:05:25 AM
Creation date
8/18/2017 11:15:51 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Faber Construction
Approval Date
8/14/2017
Council Approval Date
7/27/2017
Department
Public Works
Department Project Manager
David Voigt
Subject / Project Title
Sewer Regulators R4 & R39 Modification
Public Works WO Number
UP3633
Tracking Number
0000808
Total Compensation
$1,098,104.63
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
FABER CONSTRUCTION 4/8/2018 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> CITY OF EVERETT SPECIAL PROVISIONS <br /> 1 <br /> 1-05.3 Working Drawings <br /> IDelete all of 1-05.3 and substitute the following: <br /> After Award of the Contract, the Contractor will receive up to six (6) sets of the reduced <br /> Plans (11" x 17") and accompanying Special Provisions. In addition, the Owner will <br /> I supply up to three (3) sets of full size plans (22" x 34"). All Plans and Special <br /> Provisions will be conformed with addenda unless Contractor requests otherwise. <br /> Additional Plans and Special Provisions may be purchased by payment of the current <br /> Iprinting costs. <br /> The Contract Documents include Plans that show such details as are reasonably <br /> necessary to give a comprehensive understanding of the Work. The Contractor shall <br /> I submit alterations affecting the requirements and information in the Plans in writing to <br /> the Engineer for approval prior to performing such Work. <br /> The Engineer may supplement the Plans with additional drawings and explanations, <br /> Iconsistent with the purpose and intent of the original Plans, to detail and illustrate the <br /> Work. The Contractor shall perform the Work according to these supplemental <br /> drawings and explanations. <br /> IIn addition to supplemental drawings furnished by the Engineer, the Contract <br /> Documents may also be supplemented by shop drawings prepared by the Contractor, <br /> material supplier, or manufacturer, when necessary or as required by the Contract <br /> I Documents to detail and illustrate portions of the Work. Shop drawings shall be <br /> reviewed by the Engineer before work pursuant to those shop drawings is performed. <br /> Shop drawings may include, but not be limited to, shop details, erection plans, <br /> I masonry lay-out diagrams, reinforcing steel and bending diagrams, post tensioning <br /> plans, shoring, cribbing, cofferdam, or falsework plans, formwork plans, or hydraulic <br /> items. Catalog cuts or standard plans for commonly used manufactured items will be <br /> I considered as shop drawings. <br /> Unless otherwise requested by the Engineer, the Contractor shall submit six (6) <br /> hardcopies of complete sets of shop drawings or one electronic set in either PDF or <br /> ,I DWG formats directly to the Engineer for review and approval. If the design engineer <br /> is a full time employee of the City, the Contractor may expect fourteen (14) calendar <br /> days from submission for review and return of comments. If the design engineer is not <br /> I a full time employee of the City, the Contractor should expect thirty (30) calendar days <br /> from submission for review and return of comments. The Engineer may extend this <br /> time for good cause by notifying the Contractor. The Engineer will check and return <br /> I three (3) hardcopies or one electronic set of such drawings. On all Submittals of a <br /> drawing after the drawing's initial Submittal and return, the Contractor shall: make any <br /> corrections required by the Engineer; expressly and explicitly notify the Engineer in <br /> writing of any and all deviations from the specifications and all revisions other than the <br /> I corrections called for by the Engineer on previous Submittals; and return three (3) <br /> corrected hardcopies of the drawings or one corrected electronic drawing for the <br /> Engineer's further review. The Contractor shall plan on at least fourteen (14) calendar <br /> I days from the date of Engineer's receipt for the Engineer's review, comment, and <br /> return of submitted drawings. Some shop drawings may require more than six (6) <br /> hardcopies. The Contractor shall furnish additional hardcopies when requested. <br /> I The Contractor shall be fully responsible for the accuracy of dimensions and details on <br /> shop drawings, and for complete conformity with the Contract Documents, even if the <br /> shop drawings have been approved by the Engineer, or if the Contractor and the <br /> I Engineer agree on dimensions and details. The City does not accept shop drawings <br /> Sewer Regulators R4 and Division 1 —GENERAL REQUIREMENTS May 2017 <br /> R39 Modifications <br /> 1 WO No—UP3633 SP-61 <br />
The URL can be used to link to this page
Your browser does not support the video tag.