Laserfiche WebLink
GENERAL NOTES O STAIRWAYS PER IRC R311.7 <br /> FOR WINDOWS WITH OPERABLE OPENINGS MORE 36'MN.STAIRWAY WIDTH.LANDINGS SHALL <br /> THAN 72"ABOVE THE FINISHED GRADE OR HAVE A 36'MINIMUM DIMENSION N THE <br /> SURFACE BELOW,THE LOWEST PART OF THE DIRECTION OF TRAVEL-A LANDING IS NOT z o <br /> CLEAR OPENING SHALL BE 24'MINIMUM ABOVE REWIRED WHERE THERE IS A DOOR AT THE ' <br /> THE FLOOR EXCEPTIONS FULLY OPEN WINDOWS TOP OF AN INTERIOR RIGHT OF STAIRS, a nn <br /> WHERE A 4'SPHERE MAY NOT PASS THROUGH INCLUDING STAIRS IN AN ENCLOSED GARAGE, u m, <br /> OR WHERE FALL PREVENTION DEVICES ARE PROVIDED THE DOOR DOES NOT SWING OVER z$ <br /> PROVIDED PER ASTM F 2090 OR R612.3. THE STAIRS.RISERS TO BE 7Y'MAXNUM o N`ap.5 <br /> HEIGHT AND TREADS TO BE 10'MMIM UM m 3 <br /> PROVIDE SAFETY GLASS PER IRC R3O& DEPTH,BOTH WITH A MAXIMUM VARIATION OF 3 <br /> 53'-0' Y'.TREADS NTH SOLD RISERS TO HAVE Y' <br /> SKYLIGHTS TO BE DOUBLE PANEL,SHATTER MINIMUM TO 1Y'MAX NOSING OR 11'MINIMUM <br /> 45'-0" 8'-0' RESISTANT APPROVED RIGID PLASTIC,LAMINATED DEPTH.4"SPHERE MAY NOT PASS THROUGH N m <br /> SAFETY GLASS,FULLY TEMPERED GLASS, OPEN RISERS ON STAIRWAYS RISINGMORE _'^ 53 <br /> 22'-0' 23'-0' HEAT-STRENGTHENED GLASS,OR WIRED GLASS. THAN 30'.HANDRAIL REWIRED IF 4 OR MORE <br /> PROVIDE 4'MINIMUM CURB(OR SELF FLASHING RISERS TO BE INSTALLED BETWEEN 34'-38' < <br /> 10'-0' 13'-0' � <br /> ASSEMBLY WITH 3:12 MINIMUM PITCH OR PER ABOVE NOSING AND HAVE A 1Ya <br /> "-2"4 GRIP <br /> MANUFACTURER INSTRUCTIONS). CONTINUOUS FOR THE FULL LENGTH OF THE N m "'�+ <br /> 2'-11' 2'-6' 4'-6" 3'-3' O�i m rP w <br /> FLIGHT.RENIN ENDS TO WALL OR NEWEL. <br /> HOSE BIBBS TO BE BACKFLOW PREVENTION AND INSTALL 2x10 BLOCKING BETWEEN STUDS TO <br /> FREEZE RESISTANT TYPE. SUPPORT HANDRAIL BRACKETS.FIREBLOCX <br /> 16'-0' 3x3 MIN. 6x3 MIN. LANDING BETWEEN STUDS AT STRINGER 6'-B"MINIMUM <br /> LANDING 1 60 12 A6V ALL H WNL FRAMING ANCHORS$`;HEARWAL VERTICAL HEAD CLEARANCE PROTECT ca <br /> 1 7V MAX 1 4 01 12 ABV 60 SL DR SAF GL NAILING MUST BE INSPECTED BEFORE COVERING. ENCLOSED ACCESSIBLE UNDER STAR WALLS u <br /> TRIPLE I 1 4 3 XO AND CEILING WITH X-GWB.A FLIGHT OF D <br /> 4x10 2 F LARGER THAN 12 FEET BETWEEN FLOOR <br /> STUDS _STEP_ MAI( STEP STAIRS SHALL NOT HAVE A VERTICAL RISE U <br /> -- OPT. DOOR X28;' - - - -- 4x10!#2DF LEVELS CR LANDINGS. <br /> 4x6 #2DF LIE 1 m <br /> I p W l O BATHROOM NOTES 0 <br /> 2 FlrRmLoac TUBS AND SHafYERs PER R30211. • <br /> wd 30"x30•MINIMUM CLEAR SPACE IN SHOWER 22" <br /> O MINIMUM WIDTH SHOWER DOOR TO OPEN OUTWARD <br /> I w ^ IF PINGED.30'WIDE X 24"DEEP CLEAR SPACE <br /> .I 100 CFM HOOD I LA _ > REWIRED OUTSIDE SHOWER DOOR.ENCLOSURES <br /> DINING R M N O> TO BE SAFETY GLASS.NONABSORBENT SURFACE <br /> VENT TO EXT. I ® a x Q b UP 6'PATH SHOWER.USE CETIENT BOARD OR <br /> I: o 10 L a CBOT FIBER BOARD FOR TILE BACKING.VAPOR <br /> GARAGE 4 KITCHEN 1 " " o o BARKER NOT PERMITTED BEHIND WP.ON AT <br /> N cD<o �i W.WNL.2.5 GPM SFIONER FLOW RESTFEGTOR � <br /> 7-0' 12' TUB OR SHOWER CONTROL VALVES TO BE <br /> 4" CONC SLAB - PRESSURE BALANCE OR TIERMOSTATIC MDSNG N <br /> SLOPE 1/8": (#2HF <br /> 2)2x6 � TYPE 1.6 GAL PER FLUSH MAXIMUM TOILETS.15' I � <br /> O a <br /> 4 ----- - QEAR SPACE REQUIRED.EACH SIDE FROM L OF <br /> DBL - r--, TOILET$21'CLEAR SPACE REWIRED N FRONT. <br /> x 8 6x10 #2DF m I I INSTALL 2x10 BLOQCING FCR TOWEL BARS UP 48' a m vwi <br /> w 2 10'_0• 13'_0• STUDS - I I ABOVE FLOOR OR BELOW SAIL HEIGHT IF AT a w <br /> WINDOW.INSTALL BLOMNG FOR T.P.HOUDERS <br /> N <br /> INSULATE IXIEPoCR WALLS ADJACENT TO <br /> .f ^ SHOWERS AND TUBS AMD INSTALL NR BARRIER <br /> REFRIG <br /> N 5 x 2212 24F-V4_GLB _ SPACE jR 0 I -i I SEPARATING TF#L FROM THE SHOWERS AND <br /> 4x6 #2DF 7'-0" MIN. CLEARANCE I (4)STUDS 3 ;g o TUBS. <br /> r COLUMN I _ _ 3�g x 13y2 24F-V4 G '•P <br /> - DBL GARAGE APPLIANCES <br /> I BR'G WALL I Lal I� INIMUM <br /> STUDS w �i O ABOPILOVE FLOOR U.LSAPPROVED APPLIAWITCHES UP 18- NCES WITH <br /> En --- Iw ®;n �I .o AUTO SHUTOFF SWITCH.INSTALL IMPACT BULLARD. <br /> (3 I C 8 n n DUCTS IN GARAGE TO BE 26 GAUGE STEEL(NO <br /> o N I i TNI 1 o 1 2 o OPENINGS).INSTALL WATER HEATER ON A <br /> x GALVANIZED STEEL PAN WITH ORAN TO EXTERIOR <br /> tO WERE LEAK WOULD CAUSE DAMAGE SET <br /> ELECTRIC WATER HEATER ON R-10 INSULATED <br /> p, c�a- I INCOMPRESSIBLE BASE INSTALL SEISMIC STRAPS <br /> o •i N " MINN TOP Y AND BOTTOM)1(4"MINIMUM ABOVE <br /> N rn BR'G 2 6 #2 F C G M�I G V11V IJ LL3 o r CONTROLS).PROVIDE PRESSURE RELIEF ULE TO <br /> w , x M O WALL JS S 6" O JH, o c� I I EXTERIOR.IF FUELFIRED AN S EXCfID <br /> az N NU I I •n 100°BTUM INPUT PER 50 OU,FT.OF GARAGE <br /> M � z O z Io OPEN RAIL �-x 03" 04[L ;.; L J `�LU.�,INSTALL 2 SCREENED COMBUSTION AR <br /> �`+< I N I�.. VENTS THROUGH ORTERDOR WNL,ONE WITHIN 12' <br /> 0 `x N ° �M a O 12" SHELF ON o f <br /> aP p o > > FOYER 1 ap o OF GEaNc$ONE WITIHN 12'OF FLOOR.USE <br /> x V `� p TRIPLE - Z4 I�OPEN TO Y2WALL CAPPED ®a cv a NON-CLOSE-ABLE LOUVERED 12x12 WALL VENTS <br /> a- �N 1. V. <U STUDS a ABOVE ® 42" A.F.F. 0 e U •i I OR 8x18 FOUNDATION TYPE VENTS N WALL FOR A <br /> 5�e x 162 24F-V4 GLIB Na <br /> — — — — — PWDR 21 33 o MINIMUM NET FREE AREA OF 1 SO.N.PER 4.000 <br /> 6-X 8- O.H. GAR. DR. BN/H EACH VENT. <br /> ---- <br /> -- ° ° -� 50® vABV o O GARAGE FlRE SEPARATION <br /> INSUL. SOFFIT DBL 30 I w j •i o <br /> --- ----- ------------ Q22. 2HF 2 2x6 2HF CONT. H2-6,* <br /> rn_j iv x OPENINGS FROM GARAGE INTO SLEEPING ROOM <br /> LINE OF UPPER CANT. STUDS o NOT PERMITTED.DOOR BETWEEN GARAGE AND <br /> RESIDENCE SHALL BE Of MINIMUM THICK SOLD L�O <br /> 2636 SH 7• MAX o.wJ 2650SH 2650SH 26505 \� WOOD OR STEEL WITH SCUD OR HONEYCOMB <br /> 2-1014 2612 ABV J' 0 2612 ABV 2612 ABV 2612 AO10 CORE.OR 20 MINUTE FIRE RATED EQUIPPED WITH <br /> 2'-1014' 16'-3' c 1'-7' r-3' 8' zx M <br /> v - 3' 2'-6" 2'-8 0 A SELF-CLOSING DEVICE DUCTS N GARAGE$ <br /> .'�- I o DUCTS PENETRATING THE WALLS OR CEILINGSINSUL. & <br /> a < <br /> N 3' 1� SEPARATING THE DWELLING FROM THE GARAGE <br /> r-- I COVERED PORCH - SOFFIT SHALL BE NO.26 GAGE SHEET STEL AND HAVE <br /> I I _ 1 _ 6x10 #2DF ICD <br /> _ I I o NO OPENINGS INTO THE GARAGE FILL AROUND a <br /> o _ <br /> r N <br /> I I 6x1-0—#2DF I I N I I it OTHER PENETRATIONS WITH APPROVED MATERIAL <br /> L -J --J -------- --- L-- ---- - L- J SEPARATE THE GARAGE FROM THE RESIDENCE xx <br /> DN TO GR;DE DN TO GRADE AND ITS ATTIC AREA NTH J4'GYM INSTALLED ON a <br /> SIMPSON ECCL OPEN RAIL UP 36" THE GARAGE SIDE SEPARATE FROM HABITABLE 3 <br /> TO BEAMS ABV FIN. PORC 6x6 COLUMN SIMPSON } irK <br /> ROOMS ABOVE WITH Y'TYPE X CWB,AND WHERE <br /> LINEOF UPPER COLUMN CAP TO BM(S). THE SEPARATION IS A FLOOR-CEILING r <br /> LEVEL (LU.L.) BUILT UP TAPERED ASSEMBLY,THE SUPPORTING STRUCTURE SHALL <br /> COLUMN$PEDESTAL BE PROTECTED WITH Y"°WE' �— N <br /> TYPICAL 6 LOCATIONS o <br /> 12' 10'-0" 11'-0" 12' 7-0" 12' o z <br /> ELECTRICAL LEGEND Z N <br /> V-0" 8'-0' 2'-0' 9'-0' 2'-0' ©Z <br /> $Yq(E ALARM PER R314 AS AMENDED$LISTED PER Q �� <br /> 16'-0' 6'-0' 10'-0' 13'-0' O UL 217.INSTALL PER HOUSEHOLD WARNING J <br /> If PROVISIONS OF WPA 72&PER MF(R SPECS.TION <br /> 22'_0' 23'-0' HOUSEHOLD CUR <br /> RENT NTH BATTER BACKUP. <br /> 8'_O. INTERCONNECT EACH BEDROOM AND LEVEL <br /> - 0 0 <br /> CARBON MCNOADE ALARM PER R315 AS AMENDED. <br /> INSTALL OUTSIDE OF EACH SEPARATE SLEEPING AREA <br /> IN THE IMMEDIATE VICINITY OF THE BEDROOM. <br /> MAINFLOOR PLAN SCALE: 1/4" = 1'-0" 50S 50 CFM MRN.EXHAUST FAN-VENT TO DCIFJnOR. <br /> 667 SQ. FT. MAIN FLOOR <br /> 1206 SQ. FT. UPPER FLOOR of <br /> 1873 SQ. FT. TOTAL LIVING <br /> 572 SQ. FT. GARAGE <br />