GENERAL NOTES STAIRWAYS PER IRC R311.7 <br /> FOR WINDOWS PATH OPERABLE OPENINGS MORE O 36'MIN.STAIRWAY WIDTH.LANDINGS SHALL �r$'B <br /> THAN 72'ABOVE THE FINISHED GRADE OR HAVE A 36'MINIMUM DIMENSION IN THE Z pS5 <br /> SURFACE BELOW,THE LOWEST PMT OF THE DIRECTION OF TRAVEL A LANDING IS NOT Z�z o <br /> CLEAR OPENING SHALL BE 24'MINIMUM ABOVE REQUIRED WHERE THERE IS A DOOR AT THE ' <br /> THE FLOOR EXCEPTIONS: FULLY OPEN WINDOWS TOP OF AN INTERIOR FUG;fHT OF STAIRS, a 7 <br /> WHERE A 4'SPHERE MAY NOT PASS THROUGH INCLUDING STAIRS N AN ENCLOSED GARAGE, <br /> OR WHERE FALL PREVENTION DEVICES ARE PROVIDED THE DOOR DOES NOT SWING OVER z <br /> PROVIDED PER ASTM F 2090 OR R6123. THE STAIRS RISERS TO BE 7-Y'MAXIMUM o •a <br /> HEIGHT AND TREADS TO BE 10'MINIMUM mQ'j <br /> PROVIDE SAFETY GLASS PER IRC R308, DEPTH.BOTH WITH A MAXIMUM VARIATION OF <br /> %'.TREADS WITH SOLD RISERS TO HAVE Y al <br /> SKYLIGHTS TO BE DOUBLE PANEL,SHATTER MINIMUM TO 1Y47 MAX.NOSING OR 11"MINIMUM w ii Nm <br /> RESISTANT APPROVED RIGID PLASTIC,LAMINATED DEPTH.4"SPHERE MAY NOT PASS THROUGH . <br /> SAFETY GLASS,FULLY TEMPERED CUSS, OPEN RISERS ON STAIRWAYS RISING MORE =w F 3 <br /> HEAT-STRENGTHENED GLASS.OR WIRED GLASS. THAN 30'.HANDRAIL REQUIRED IF 4 OR MORE <br /> 45'-O' PROVIDE 4 MINIMUM CURB(OR SELF FLASHING RISERS TO BE INSTALLED BETWEEN 34'-38' w <br /> ASSEMBLY WITH 3:12 MINIMUM PITCH OR PER ABOVE NOSING AND HAVE A 1Y-2"0 GRIP a <br /> MANUFACTURER INSTRUCTIONS). CONTINUOUS FOR THE FULL LENGTH OF THE <br /> 12'-11' 11'-10' 2'-5' 12'-4' v m �' <br /> FLIGHT.RETURN ENDS TO WALL OR NEWEL w <br /> 101 2'-5' HOSE BUM TO BE BACKFLOW PREVENTION AND INSTALL 2x10 BLOCKING BETWEEN STUDS TO <br /> FREEZE RESISTANT TYPE. SUPPORT HANDRAIL BRACKETS.FIREBLOCK <br /> S-Y BETWEEN STUDS AT STRINGER 6'-8'MINIMUM <br /> ALL HODOWNS.FRAMING ANCHORS&SHEARWALL VERTICAL HEAD CLEARANCE.PROTECT <br /> NAILING MUST BE INSPECTED BEFORE COVERING. ENCLOSED ACCESSIBLE UNDER STAIR WALLS <br /> 5040 XO 540 XO 5040 XO <br /> AND CEILING WITH Yt"GWB.A FLIGHT OF 0 <br /> STAIRS SNAIL NOT HAVE A VERTICAL RISE L <br /> Fl <br /> LARGER THAN 12 FEET BETWEEN FLOOR <br /> (2)2x6 #2HF Wj4x8 #2DF 4x8 #2DF LEVELS OR LANDINGS. <br /> WR � l a O1 BATHROOM NOTESES ~to d Z FIRFBLOCN TUBS AND SHOWERS PER R30211.w= - I �n 30"x30"MINIMUM CLEAR SPACE IN SHOWER.22" <br /> MINIMUM WIDTH SHOWER DOOR TO OPEN OUTWARD <br /> `Ox�- �N w a IIF HINGED.30'WIDE X 24"DEEP CLEAR SPACE <br /> c x U) ® mL <br /> REQUIRED OUTSIDE SHOWER DOOR.ENCLOSURES <br /> N 0MN [KD <br /> O. TO BE SAFETY GLASS NONABSORBENT SURFACE <br /> m� O BONUS R M BED RM #4 BED RM ##3 UP 6'WITH SHOWER.USE CEMENT BOARD OR <br /> CEMENT FIBER BOARD FOR TILE BACKING.VAPOR <br /> BARRIER NOT PERMITTED BEHIND W.P.GYM AT <br /> a Z EXi.WALL 25 CFM SHOWER FLOW RESTPoCT(XL <br /> TUB OR SHOWER CONTROL VALVES TO BE <br /> > _ PRESSURE BALANCE OR THERMOSTATIC MIXING - <br /> F_ �O� TYPE.1.6 GAL PER FLUSH MAXIMUM TOILETS.15' <br /> o Q 6 5-10' CLEAR SPACE REQUIRED.EACH SDE FROM t OF <br /> ~ Do ®I I TOILET&21'CLEAR SPACE REGAINED IN FRONT. m w INSTALL ZxIO BLOCIING FCR TOWEL BARS UP 48' < N <br /> 6 ABOVE FLOOR OR BELOW SILL HEIGHT IF AT o w <br /> 12' 2 WINDOW.INSTALL BLOCKING FOR T.P.HOLDERS <br /> E-l� <br /> 6'-4" 9'-10' Z INSULATE EXTERIOR WALLS ADJACENT TO <br /> ¢ SHOWERS AND TUBS AMD INSTALL AIR BARRIER <br /> 75 CFM W.H.2q 4'-O' S'-10" 5'-Y 2'-O' 7-\0 <br /> > .® SEPARATING THEM FROM THE SHOWERS ALID <br /> AN V.T.O.S. a TUBS <br /> STUDBL —LDS wI S 6 26 56 BF _ 172_WALL UP 36�A.F.F. v EGRESS WINDOWS PER R310 <br /> S ORY O EMERGENCY ESCAPE AND RESCUE OPENINGS <br /> p BATH =w� SHALL HAVE A SILL HEIGHT OF NOT MORE THAN <br /> N Hr x w m o 44 INCHES MEASURED FROM THE FINISfD FLOOR <br /> o �I "i V.T.O.S. WASH (A ®•i ��= I <br /> I o v..cv i0 THE BOTTOM OF THE CHEM OPENING. <br /> v Ld w Z 50® M to N�k EMERGENCY ESCAPE AND RESCUE OPENINGS <br /> w ® m <br /> -- __---___- o� Z N O v SHALL HAVE A MINIMUM NET CLEAR OPENING OF <br /> S & P -- - 5' TUB/SHWR 5.7 SQUARE FEET(5.0 S.F.AT GRADE FLOOR) <br /> z ------- O THE MINIMUM NET CLEAR OPENING HEIGHT SHALL <br /> -I TYPE "B" GAS NT �FJ SEE NOTES BE 24 INCHES,THE MINIMUM NET CLEAR <br /> FIRE & DRAFT TOP I a < EMEROPEN1(;ONCESCPPE AND RESCUWIDTH SHALL BE 20 ES.AND <br /> OPENINGSMSTR SUITE ALL VOIDS / R 08.2 I I l I -— <br /> WALK-IN I `j a --- S & P---- i 3 SHALL BE OPERATIONAL FROM THE INSDE OF <br /> WARDa --_- - m THE ROOM WITHOUT THE USE OF ISYS,TOOLS <br /> df --- -- I 60 BP WARD = OR SPECIAL KNOWLEDGE. <br /> FULL HT. STUDS KITH 24 I N PLANT I 2s ATTIC ACCESS PER R807.1 <br /> SLOPED DBL TOP IPL. ® TRIPLE I SHELF I I OPEN TO O O © 22'x30'MINIMUM ROUGH FRAMED OPINING. <br /> BOT. CHORD OF SFISSOR STUDS I I 5-6' 7'-6' a INSULATE AND WEATHERSTRIP DOOR 12'HEIGHT <br /> DO NOT BREAK STUDS. (2)2x6 #2HF I BELOW wo <br /> I I INSULATION OHM 30'MINIMUM CLEAR HEADROOM.TRIPLE <br /> 5TRIPLE z <br /> 0 (2)2x4 #2HF EA. WINDOW 20 C STUDS I BED RM #2 STUDS <br /> Plc o I � ELECTRICAL LEGEND <br /> I <br /> 30 50 SH 30 50 SH 30 50 SH (2)2x6 #2HF ---_R_AT - SMOKE ALARMN PER R314 AS AMENDED&LISTED PER <br /> -------- - UL 217.INSTALL PER HOUSEHOLD WARMING w O 0::30 12 ABV 3026 ABV 30 12ABV 6026 PIC VAULTED c sA PROVISIONS OF NEPA 72&PER MFGR.SPECS.110V <br /> I HOUSEHOLD CURRENT WITH BATTERY BACKUP. <br /> gjo INTERCONNECT EACH BEDROOM AND LEVEL <br /> 3" 3'-0.3' 3'-0- S-3" 2'-0" L2-1- CARBON MONOXIDE ALARM PER R315 AS AMENDED. <br /> O JI ® INSTALL OUTSIDE OF EACH SEPARATE SLEEPING AREA <br /> 2 2x4 2HFN EA. WINDOW IN THE IMMEDIATE VICINITY OF THE BEDROOM. J o <br /> UNE OF PORCH BLW - - cP <br /> 75® CONTINUOUS OPERATION COMBINATION SPOT AND WHOLE C 7 w z <br /> 16 50 30 50 SH 16 50 NH HOUSE EXHAUST FOR INTERMITTENT TIMED OPERATION, 5i <br /> FULL Hr. STUDS WITH MUCH LARGER CAM CAPACITY REQUIRED.SEE WHOLE <br /> SH U12A,8V ;3 <br /> SLOP DBL TOP PL. ® HOUSE VENTILATION NOTES ON MECHANICAL SiEET FOR r <br /> BOT. ORD OF SCISSOR SIZING FORMULA'REQUIREMENTS&OPTIONS' <br /> DO NO BREAK STUDS. 50 ® 50 CFM MIN.EXHAUST FAN-VENT TO EXTERIOR. CON 3'-3' r- O <br /> 3 �U <br /> F �Z_ <br /> 16'-0' 6'-0" 10'-0" 13'-0' ©Z <br /> 45'-0" J <br /> w <br /> v� <br /> UPPER FLOOR PLAN SCALE: 1/4" = V-0' <br /> 1206 SQ. FT. UPPER FLOOR <br /> 3� <br />