2012 Washington St Aergy Code Compliance Forms for Commercial,Group Rio>3 story R2 and R3 <br /> Mechanical Permit ' Page I of <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stones and all R1 Revised Aug 2015 <br /> Project Address 2205 BROADWAY Date 5/13/2016 <br /> The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Location in Building Department <br /> Code Section Code Provision Information Required-Must be in permit documents <br /> (yes,no,na) Documents Notes <br /> GENERAL PROVISIONS <br /> Equipment Sizing&Performance <br /> MECH- <br /> yes C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 LOAD- <br /> CALC <br /> yes C403.2.2 Equipment and system Output capacities of heating and cooling equipment and systems do not exceed the next larger MECH-EQ <br /> sizing available equipment size above the calculated loads;note exceptions taken <br /> na C403.2.5 Minimum ventilation Ventilation(natural or mechanical)provided per IMC;indicate mechanical ventilation is capable <br /> of being reduced to minimum requirement per IMC <br /> C403.2.3& with type,SUM t <br /> complete MECH <br /> l <br /> equipment schedules Equipment minimum Provide a ui ues or corn -SUM we,ca acit ,efficiency, MECH <br /> yes C403.2.3.2& - <br /> e ncq p p yP P YSUM <br /> C403.2.12.1 efficiency test standard(or other efficiency source)for all mechanical equipment <br /> M-111& <br /> MECH- <br /> yes C403.2.13 Electric motor efficiency Provide equipment schedule with hp,rpm,and efficiency for all motors,note exceptions taken FANSYS- <br /> SUM <br /> na C403.2.10.1 Fan power limitation For all applicable systems>5hp,provide system total nameplate hp in MECH-FANSYS-SUM <br /> form <br /> na C403.2.10.1 Fan power limitation For all applicable fan systems>5hp,verify fan system motor hp or bhp complies with fan <br /> power limits per Table C403.2.10.1(1),provide MECH-FANSYS form for each system <br /> MECH- <br /> yes C403.2.10.2 Motor nameplate hp Indicate fan motors specified are the smallest available motor hp size greater than fan bhp, FANSYS- <br /> note exceptions taken SUM <br /> C403.2.10.3 MECH- <br /> yes &C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. FANSYS- <br /> SUM <br /> na C403.2.3 ca ximum air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit <br /> paty <br /> na C403.2.3.1 Non-standard water-cooled Full-load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard <br /> chillers operational conditions <br /> na C403.2.12.1.1 Centrifugal fan cooling Large capacity cooling towers with centrifugal fan(s)meet efficiency requirements for axial fan <br /> towers open circuit cooling towers <br /> na C403.2.3 Forced air furnace and unit Indicate intermittent ignition or IID,flue/draft damper&jacket loss <br /> heaters <br /> na C403.2.3.3 Packaged electric Verify all packaged electric equipment that provides>20,000 Bluth cooling capacity and <br /> heating/cooling equipment heating is a heat pump,note in equipment schedule <br /> na C403.2.3.4 Humidification Indicate method of humidification(note requirements for systems with economizer) <br /> HVAC System Controls&Criteria <br /> yes C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans,including perimeter systems M-1 11 <br /> na C403.2.4.1.1 Heat pump supplementary Indicate staged heating(compression/supplemental)and outdoor lock-out temperature is set <br /> heat to 40°F or less <br /> M-111 <br /> yes C403.2.4.2 Setpoint overlap(deadband) Indicate 5°F deadband minimum for systems controlling both heating&cooling <br /> yes C403.2.4.3 Automatic setback and Indicate zone t-stat controls with required automatic setback&manual override M-111 <br /> shutdown <br /> yes C403.2.4.3.3 Automatic(optimum)start Indicate system controls that adjust equip start time to match load conditions <br /> M-111 <br /> C402.4.5.2& OSA,exhaust,and relief air Indicate location of outdoor air supply intake,and exhaust and relief outlet dampers;verify M-1 11 <br /> yes C403.2.4.4 dampers Class 1 leakage rating and control type motorized or gravity);note exceptions taken <br /> P 9 9 YP ( 9 Y). <br /> na C402.4.5.2 Return air dampers Indicate location of return air dampers that are integral to economizer operation;verify <br /> motorized control and Class 1 leakage rating;note exception taken <br /> na C402.4.5.1 Stairway and shaft vents Indicate location of stairway and shaft vents,verify Class 1 leakage rated motorized dampers <br /> and method of activation <br /> na C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls <br /> na C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions <br /> na C403.2.4.6 Combustion heating Indicate modulating or staged control <br /> equipment <br />