Laserfiche WebLink
2012 Washington State Ener*ode Compliance Forms for Commercial, Grouo, and >3 story R2 and R3 <br /> 7Washiln�gtoon <br /> •State Ener Code Com liance Forms for Commercial Buildin s includin R2&R3 over3 stories and all R1 Revised Au 2015 <br /> Project Address: 2205 BROADWAY Date 5/13/2016 <br /> EVERETT,WA For Building Dept. Use <br /> Applicant Name: Walgreens Co.-Brant Heflin <br /> Applicant Address: 106 Wilmont Rd.MS#1640,Deerfield,IL 60015 <br /> Applicant Phone: (847)315-4595 <br /> Economizer Economizer Exceptions-Alterations or Replacement System ID Equipment Compliance <br /> Exception Table Alterations or replacement of existing mechanical equipment Type Path <br /> C101.4.3.1 may comply with an applicable economizer compliance Option <br /> Summary as defined in Table C101.4.3.1. <br /> Refer to Section Economizer Exceptions-Simple Systems Cooling <br /> C403.3.1 and SS Exp1 Qualifying small equipment. Per unit limit is 33,000 Btu/h.Per building System ID Capacity <br /> C403.4.1 for capacity limit for this exception is 72,000 Btu/h or 5%of required building (Btu/h) <br /> descriptions of air economizer capacity,whichever is greater.Efficiency shall be 15% FC-1/CU-1 11500 <br /> economizer better than required minimum.Not eligible:non-unitary equipment,unitary <br /> provisions and equipment installed outdoors or in mech room adjacent to outdoors, <br /> exceptions. For equipment installed during new construction,shell-and-core construction, <br /> alterations refer or initial tenant improvement. <br /> to Section <br /> C101.4.3.2 and Total Claimed Exempt Capacity: 11500 <br /> Table <br /> C101.4.3.1. Total building air economizer capacity(if claimed>72,000 Btu/h): <br /> Alternate SS Expl Capacity Limit: <br /> SS Exp2 Systems with dehumidification that affect other systems such that air System ID <br /> economizer would increase energy consumption. <br /> SS Exp3 Group R cooling equipment. Per unit limit is 20,000 Btu/h for Cooling <br /> simple cooling equipment installed outdoors or in a mech room System ID Equipment Capacity <br /> adjacent to the outdoors.For simple cooling equipment installed Location (Btu/h) <br /> in other locations the unit limit is 54,000 Btu/h.Efficiency shall be <br /> 15%better than required minimum. <br /> SS Exp4 Pending rule per WAC 51-11C-40331. Equipment cooling efficiency meets System ID <br /> or exceeds 64%in Climate Zone 4C and 59%in Climate Zone 5B per <br /> revised Table C403.3.1(2). <br /> SS Exp5 Simple cooling equipment for dedicated server rooms,electronic <br /> equipment rooms(including elevator machine rooms),or telecom switch <br /> rooms. These systems are eligible under CS Exp5.The total allowance Document under CS Exp5 <br /> for equipment utilizing this exception includes the sum of both simple and <br /> complex systems. <br /> Id <br />