Laserfiche WebLink
KEY NOTES - <br />EXISTING BUILDING ROOFTOP <br />2O <br />EXISTING AT&T ANTENNA MOUNT, TYP. <br />3O <br />NEW AT&T ANTENNA TYP. <br />4O <br />NOT USED <br />ONOT <br />USED <br />OANTENNA GROUNDING, #2 AWG STRANDED GREEN <br />INSULATED COPPER CONDUCTOR TO COLLECTION <br />GROUND BAR AT ANTENNA LEVELS <br />ORRH GROUNDING, #2 AWG STRANDED GREEN <br />INSULATED COPPER CONDUCTOR TO COLLECTION <br />GROUND BAR AT ANTENNA LEVEL <br />O8 EXISTING COLLECTION GROUND BAR FINAL GROUND <br />LEAD, /2 AWG STRANDED GREEN INSULATED COPPER <br />CONDUCTOR TO COLD WATER PIPE <br />OEXISTING COLLECTION GROUND BAR <br />7 <br />9 <br />SECTOR <br />\ <br />/ <br />I <br />SECTOR <br />IBI <br />9 <br />8 <br />2 <br />A 0. <br />SECTOR �! <br />C. <br />6 / 1 <br />I <br />3 <br />ANTENNA GROUNDING PLAN <br />22"x34" SCALE 3l8" =1'-0" <br />11"07 SCALE 3'16" = 1'-0" <br />3 <br />2 <br />GENERAL GROUNDING NOTES <br />1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND <br />CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. <br />2. ALL GROUNDING SHALL CONFORM TO THE CURRENT AT&T STANDARDS, <br />3. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO <br />EQUIPMENT IS NOT BLOCKED. <br />4. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND <br />CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR <br />DAMAGE TO THE CONDUIT. <br />5. PREFABRICATED SHELTER WILL BE PROVIDED WITH INTERNAL WIRING AND EQUIPMENT INSTALLED. <br />FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT REFER TO DRAWINGS PROVIDED BY SHELTER <br />MANUFACTURER. <br />6. FOR INTERIOR EQUIPMENT LAYOUT AND LOCATION, SEE SHELTER MANUFACTURER'S DRAWINGS AND <br />SPECIFICATION. IN CASE OF CONFLICT THE DRAWINGS GOVERN. <br />7. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). <br />8. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING TWO <br />(2) HIGH PRESS CRIMPS. <br />9. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A <br />VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. <br />10. ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PLANT AT THEIR MATING SURFACES AND <br />INSTALL PER MANUFACTURER'S RECOMMENDATIONS. ALL EXTERIOR GROUND CONNECTIONS SHALL BE <br />COATED WITH A CORROSION RESISTANT MATERIAL. <br />11. ALL EXTERIOR GROUND CONDUCTORS SMALL BE E2 AWG TIN PLATED COPPER UNLESS OTHERWISE <br />INDICATED. <br />I I GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, -Y'm 10-FT. LONG, AND <br />SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18" BELOW FINAL GRADE OR 6" BELOW FROST <br />LINE FOR MAXIMUM DEPTH. <br />13. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO <br />BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. <br />14. USE OF 9O' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN <br />45°BENDS CAN BE ADEQUATELY SUPPORTED. <br />15. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM BELOW <br />THE FROST LINE. <br />16. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-O' FROM EQUIPMENT <br />CONCRETE PAD, SPREAD FOOTING, OR FENCE. <br />17. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED <br />SPRAY. <br />18. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING <br />19. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS <br />OR AT GROUNDING POINTS PROVIDED (2 MINIMUM) <br />20. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. <br />21. MINIMUM BENDING RADIUS FOR GROUNDING CONDUCTORS IS 8' WHEN BENDING IS <br />NECESSARY. GROUND CONDUCTORS ARE TO BE AS STRAIGHT AS POSSIBLE. <br />72. NO SPLICES PERMITTED IN GROUND CONDUCTORS. <br />23. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S SPECIFIED <br />VALUES. <br />24. GROUND BARS SHALL NOT BE FIELD MODIFIED. <br />25. ALL HORIZONTAL FENCE SECTIONS TO BE GROUNDED WITH 8" SINGLE BARREL GROUND <br />STRAPS. <br />2& USE PANI SCHEME FOR LOADING ON MGB AS DISCUSSED IN NSTD 119. 33 & 36. <br />I 22"x34" : NONE <br />GROUNDING NOTES 1%-:1 SCALESCALE: NONE 21 <br />v <br />Schematic ofThekDeterrent Solution at Cellular Site aw <br />A, <br />3Ry. <br />LEGEND <br />Theft Deterrent Composite Cable, <br />ERICO CC5AO5CB (AT&T Port <br />funber:CE025.228, Rosenberger <br />Port Number: WR-STDCABLE-250) <br />02 AWG Sold Tmied Copper <br />Wire Bare, Below Grade <br />'"IlW Coaxial and Othel Feeders <br />m,a. •oo,raoe ratwvre4+o�lr oiraertcauarraw <br />xc,o <br />maw ananao4e..ow.ewAreo�.,euroAvl�cloer[AranrMIXM�N, <br />I.araw.x-morvloaw4raAAw�s®Hrti+s sru <br />Arc�it <br />ws+.,or*..,. «4x.rxouarxnamcsr�orrcrelR.i rrx«+r, <br />ac.ra ��� HarrA4rt.wworz <br />m..a I oa.*•o.a.. rawm.,wow,oal�'.�wx�lam«a_• <br />gpptcn(,W a1ii T1Y,'��. r..r <br />1 THEFT DETERRENT GROUND ARRANGEMENT <br />N <br />'n <br />a� <br />> <br />V5 <br />❑ <br />i� <br />z <br />O <br />/ <br />G <br />+3 <br />fA <br />o <br />J °' <br />U <br />`n <br />W Cn <br />Z� <br />'Wn <br />V <br />(((c <br />CAMP+ <br />ASSOCIATES <br />19401 40TH AVE. W., SLIITE 304 <br />LYNNWOOD, WA 98036 <br />PHONE: (425) 740-6392 <br />FAX :(425)224-1614 <br />W W W.CAMPASSOC.COM <br />DATE: 01/21/16 <br />DRAWN BY: EAT <br />CHECKED BY: PN <br />I REVISIONS 1 <br />7727 <br />REGISTERED <br />ARCHI ECT <br />UL NI <br />�A <br />OF ASHINGTON <br />SN91—SOUTH EVERETT <br />209 EAST CASINO ROAD <br />EVERETT, WA 98208 <br />SI-TILT TILE <br />ANTENNA GROUNDING PLAN <br />AND NOTES <br />SHEET NUMBER <br />22"x34" SCALE: NONE <br />-eS� <br />11 "x17" SCALE: NONE v <br />F <br />JOB No. SN91 <br />