TO ANTENNAS <br />ANTENNA CABLE - 12 <br />II <br />Type GT Type TA JINSULAT�E�D <br />I WEATHERPROOFING KIT <br />WEATHERPROOFING KIT 2-1/2"0 MAX. <br />THROUGH CABLE TO TOP OF TEE OF HORIZONTAL RUN JUMPER REQUIRED(SEE NOTE 3 <br />GROUND ROD. AND TAP CABLES. Type VV Type VS ONLY FOR 1%"0 CSTANDARD GROUND KIT <br />THROUGH VERTICAL CABLE TO CABLE TAP DOWN AT 45- TO OR FOR EASE OF(EYED CABLE GROUND KI <br />CONNECTION (TYP.)REFER TO NOTE. 6 AWG STRANDED <br />VERTICAL STEEL SURFACE OR VERTICAL STEEL SURFACE OR # <br />TO THE SIDE OF EITHER SIDE OF HORIZONTAL OR COPPER GROUND WIRE <br />HORIZONTAL OR VERTICAL VERTICAL PIPE. (GROUNDED TO <br />PIPE CONNECTORANTENNA CABLE IN GROUND BAR) (SEE <br />Type VN Type H$ WEATHERPROOFING (TYP.PROOFINGCABLE TRAY OC NOTE i & 2 <br />YP EQUIPMENT LOCATION ) <br />HORIZONTAL CABLE TAP TO HORIZONTAL CABLE TAP TO REFER TO NOTE 2(') CONNECTION OF COAX GAB'_E GROUND <br />VERTICAL STEEL SURFACE OR HORIZONTAL STEEL SURFACE Type GY Type GR KIT TO ANTENNA CABLE <br />THE SIDE OF HORIZONTAL OR PIPE. CABLE OFF YP COLLECTION GROUND <br />PIPE SURFACE. THROUGH CABLE TO SIDE OF CABLE TAP TO TOP GROUND BAR MOUNTED <br />GROUND ROD ROD FROM ANTENNA FRARRNEAR/BELOW TAIL 5. <br />ANTENNA. <br />SUPPORTTHIS SHT. NOTES: <br />1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND <br />NOTE: ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. <br />CADWELL "TYPES" SHOWN ABOVE ARE Type XB lil�c, RADIUS <br />EXAMPLES - CONSULT WITH PROJECT Type INC MINIMUM 2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT <br />MANAGER FOR SPECIFIC TYPES OF CROSS OF HORIZONTAL #2 AWG STRANDED, WITH TWO -HOLE LUG. <br />CADWELD TO BE USED FOR THIS FROM ANTENNA MAS <br />CABLES LAPPED AND NOT THROUGH AND TAP CABLES D, INSULATED COPPER <br />PROJECT. CUT. TO GROUND ROD AIR TERMINALS (WHR CONDUCTOR BONDED 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD <br />REQUIRED) CONDUCTOR. TO GROUND WIRE SHRINK SHALL NOT BE USED. <br />ALONG CABLE TRAY TO <br />EXTERIOR GROUND BAR. <br />CADWELD DETAILS 22"x34" SCALE: NO <br />1 COAXIAL CABLE GROUND WIRE TO GROUND BAR CONNECTION 22".34 L <br />SCALE: NONE A <br />11"x1T SCALE: NONE 11"07" SCALE: NONE <br />GROUND BAR NOTES: STRANDED CU WIRE <br />VERIFY THE HARDWARE (NUTS/BOLTS/WASHERS) FOR WITH GREEN, 60OV, <br />INSTALLING THE GROUND BARS AND CONNECTING THE THHN/THWN <br />WIRE LUGS TO THE GROUND BARS ARE STAINLESS STEEL INSULATION. SIZE AS <br />FOR OUTDOOR APPLICATIONS AND NON -CORROSIVE SPECIFIED PANI SCHEME SPECIFICATIONS: <br />(COPPER, GALVANIZED STEEL, STAINLESS STEEL) FOR SS NUT PRODUCER (P) <br />INDOOR APPLICATIONS. <br />COAXIAL GROUND KITS W/ LONG CONNECTS TO WIRELESS EQUIPMENT CABINETS, CABLE ENTRANCE <br />SEE HARDWARE CONFIGURATION ON RIGHT BARREL COMPRESSION LUGS W/ TWO -HOLE LUG, <br />SS SPLIT LOCK WASHER BOLTED TO GROUND GROUND BAR (CEGB), MAIN DISTRIBUTION FRAME GROUND BAR <br />/y TWO (2) "BOLTS AND LOCK BAR USING %"-16 x (MDFB), AND STANDBY ENGINE -GENERATOR SET FRAME AND OTHER <br />HARDWARE TO BE / MATCH EXISTING GB HOLES y4" WASHERS (TYP.) SUPPLY AND NOISE PRODUCING EQUIPMENT <br />INSTALLED BY CONTRACTOR. SS FLAT WASHER 1Y4" STAINLESS STEEL <br />HARDWARE ACCEPTABLE IF GB HAS Y4" HOLES AND LUGS HEX HEAD BOLTS AND ABSORBER (A) <br />ARE Y.") HARDWARE. <br />(#2) TWO HOLE CONNECTS TO THE EARTH ELECTRODE SYSTEM INCLUDING CENTRAL <br />SANDWICHING THE BAR IS ALLOWABLE (AFTER THE FACE COMPRESSION LUG P OO N I OFFICE GROUND GRID, BUILDING STRUCTURAL GROUND, METALLIC <br />GROUND BAR ON WALL, <br />OF THE BAR IS FULL AND LOCAL AT&T APPROVES IN FLOOR OR ON C O O O 0 WATER PIPE SYSTEM, ANTENNA SUPPORTING STRUCTURE GROUND <br />LIEU OF LARGER-2nd BAR) APPLY 'NO OX' ANTENNA TOWER SYSTEM, AND ELECTRICAL SERVICE ENTRANCE GROUND <br />0 0 0� 0 0 0 0 0 OO <br />NON -ISOLATED (M <br />CONNECTS TO EQUIPMENT NOT IN AN ISOLATED GROUND ZONE (IGZ) <br />CAD WELD WITH #2 O O O SUCH AS CBN EQUIPMENT FRAME GROUNDS AND DC GROUND <br />AWG SOLID TINNED CONDUCTORS FOR DC POWER SYSTEMS THAT SERVE CBN OR BOTH <br />BARE CU WIRE OR CBN AND IBN EQUIPMENT <br />WIRE <br />NOTE: BUS BAR STRANDED <br />GR EN,U 60OV, ISOLATED (1) <br />NEVER DRILL THE GB THHN/THWN INSULATION CONNECTS TO THE SINGLE POINT CONNECTION BAR (SPCB), FOR IBN <br />NO DOUBLE STACKING SS FLAT WASHER TO ANTENNA EQUIPMENT <br />NO OVERLAPPING WASHERS STRUCTURE, BUILDING, <br />RING GROUND OR MGB <br />SS BOLT <br />GROUND BAR HARDWARE 22"x34"SCALE: NONE 3 GROUND BAR CONNECTION DETAIL AND NOTES 22"x34" SCALE: NONE <br />1/":17"SCALE: NONE it"x17­SCALE: NONE <br />#2 AWG STRANDED JUMPER W/ <br />SHORT BAREL COMPESSION LUGS <br />GENERAL NOTE (T&B #54205 OR #5407), USE 772-1 <br />STAR WASHERS, LOCK WASHER , <br />1. ALL CADWELD CONNECTIONS ON GALVANIZED AND SHEET METAL SCREWS TO <br />SURFACES SHALL BE CLEANED THOROUGHLY SECURE TO EXTERNAL GROUND BAR <br />AND COVERED WITH TWO (2) COATS OF BY CONTRACTOR. <br />SHERWIN WILLIAMS GALVANITE PAINT B350W3 <br />OR EQUAL. <br />COAXIAL GROUND KITS W/ LONG <br />2. ALL ELECTRICAL CADWELD AND MECHANICAL <br />BARREL COMPRESSION LUGS W/ <br />GROUND CONNECTIONS WILL HAVE TWO (2) %- BOLTS AND LOCK <br />NON -OXIDATION COMPOUND APPLIED TO <br />CONNECTION. WASHERS (TYP.) SUPPLY AND <br />INSTALLED BY CONTRACTOR. <br />3. ANY METAL OBJECTS WITHIN 6 FEET OF THE O O <br />EXTERNAL GROUND RING SHALL BE GROUNDED. <br />4. ALL GROUNDING MATERIALS AND CADWELD tY ® 7ifs" DIA. (TYP.) <br />MOLDS, SHOTS, ETC., SHALL BE FURNISHED _ <br />AND INSTALLED BY CONTRACTOR, UNLESS 0 O 4" x 10" x Y4^ THK. COPPER <br />OTHERWISE NOTED. GROUND BAR W/ 4" INSULATED <br />STAND OFF. (HANGER #GBI-14410) <br />5. THE ELECTRICAL CONTRACTOR SHALL FOLLOW <br />GROUNDING SYSTEM INSTALLED AND TESTING 0 SUPPLY AND INSTALL BY <br />PROCEDUR CONTRACTOR <br />4" #2 AWG INSULATED STRANDED <br />COPPER CONDUCTOR DOWNLEAD TO <br />MASTER GROUND BAR OR OTHER <br />1p^ FINAL GROUNDING POINT <br />> <br />U <br />a <br />Z <br />iz Q <br />3 <br />} <br />ON <br />o <br />0) <br />to <br />,N <br />'W <br />V <br />((( <br />CAMP+ <br />ASSOCIATES <br />19401 40TH AVE, W., SUITE 304 <br />LYNNWOOD, WA 98036 <br />PHONE: (425) 740-6392 <br />FAX: (425) 2241614 <br />W W W.CAMPASSOC.COM <br />DATE: 01/21/16 <br />DRAWN BY: EAT <br />CHECKED BY: PN <br />REVISIONS <br />REV.: DATE: DESCRIPTION: BY: <br />QO <br />01/11/16 <br />ISSUED FOR <br />EAT <br />Qj <br />01/21/16ISSUED <br />FOR <br />FINAL PERMIT <br />EAT <br />REGISTERED <br />ARCHI ECT <br />UL NI <br />OF ASHINGTON <br />01/1-1/2016 <br />31—SOUTH EVERETT <br />EAST CASINO ROAD <br />/ERETT, WA 98208 <br />SHEET TITLE <br />ROUNDING DETAILS <br />SHEET NUMBER <br />22"x34"SCALE I2"c1'-0" 22'k34"SCALE: NONE 22"x34"SCALE: NONE <br />NOT USED "xT'SCALE74"=V-0" .0 NOTES 11"x1T'SCALE:NONE 6 !COLLECTION GROUND BAR 7 - <br />11'Y1T'SCALE:NONE <br />JOB No. SN91 ell <br />