My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1133 TTEREVE DR BETTY CARE 2019-11-19
>
Address Records
>
TTEREVE DR
>
1133
>
BETTY CARE
>
1133 TTEREVE DR BETTY CARE 2019-11-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2019 1:59:38 PM
Creation date
10/25/2017 9:18:19 AM
Metadata
Fields
Template:
Address Document
Street Name
TTEREVE DR
Street Number
1133
Tenant Name
BETTY CARE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
minimum and 30 inches maximum. <br /> R325.8.3.1 Fixed position grab bars.Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from <br /> the rear wall. <br /> R325.8.3.2 Swing-up grab bars.Swing-up grab bars shall be a minimum of 28 inches in length fromthe rear wall. <br /> R325.8.4 Grab bars at bathtubs.Horizontal and vertical grab bars shall meet the requirements of R325.8. <br /> R325.8.4.1 Vertical grab bars.Vertical grab bars shall be a minimum of 18 inches long and installed at the control end wall and <br /> head end w all.Grab bars shall mount w ithin 4 inches of the exterior of the bath tub edge or w ithin 4 inches w ithin the bath tub. The <br /> bottom end of the bar shall start between 36 inches and 42 inches above floor grade. <br /> EXCEPTION:The required vertical grab bar can be substituted with a floor to ceiling grab bar meeting the <br /> requirements of R325.8 at the control end and head end entry points. <br /> R325.8.4.2 Horizontal grab bars.Horizontal grab bars shall be provided at the control end, head end, and the back w all w ithin the <br /> bathtub area.Grab bars shall be mounted betw een 33 inches and 36 inches above floor grade. Control end and head end grab bars <br /> shall be 24 inches rninirrum in length. Back wall grab bar shall be 36 inches minimum in length. <br /> R325.8.5 Grab bars at shower stalls.Where show erstalls are provided to meet the requirements for bathing facilities, grab bars <br /> shall meet the requirements of R325.8. <br /> EXCEPTION:Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab <br /> bars at the seat end wall.Avertical floor to ceiling grab bar shall be installed within 4 inches of <br /> the exterior of the shower aligned with the nose of the built-in seat. <br /> R325.8.5.1 Vertical grab bars.Vertical grab bars shall be 18 inches minimum in length and installed at the control end walland <br /> head end wall.Vertical bars shall be mounted w ithin 4 inches of the exterior of the showerstall or w ithin 4 inches inside the shower <br /> stall. The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. <br /> R325.8.5.2 Horizontal grab bars.Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 <br /> inches and 36 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent walls.Horizontal <br /> grab bars shall not interfere w ith shower control valves. <br /> R325.9 Ramps.All interior and exterior ramps, w hen provided, shall be constructed in accordance with Section R311.8 w ith a <br /> maximum slope of 1 vertical to 12 horizontal. The exception to R311.8.1 is not allowed foradult family homes. Handrails shall be <br /> installed in accordance with R325.9.1. <br /> R325.9.1 Handrails for ramps.Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal <br /> and 1 vertical and 20 horizontal in accordance w ith R311.8.3.1 through R311.8.3.3. <br /> R325.10 Stair treads and risers.Stair treads and risers shall be constructed in accordance w ith R311.7.5. Handrails shall be <br /> installed in accordance with R325.10.1. <br /> R325.10.1 Handrails for treads and risers.Handrails shall be installed on both sides of treads and risers numbering from one riser <br /> to multiple risers.Handrails shall be installed in accordance w ith R311.7.8.1 through R311.7.8.4 <br /> R325.11 Shower stalls.Where provided to meet the requirements for bathing facilities, the minimum size of show erstalls for an <br /> adult family home shall be 30 inches deep by 48 inches long. <br /> [Statutory Authority:RCW 19.27.031 and chapters 19.27 and 34.05 RCW.13-04-068,§51-51-0325,filed2/1/13,effective 7/1/13.Statutory <br /> Authority:Chapter 19.27 RCW.10-18-036,§51-51-0325,filed8/25/10,effective9/25/10.StatutoryAuthority:RCW 19.27.190,19.27.020,and <br /> chapters 19.27 and 34.05 RCW.09-04-023,§51-51-0325,filed 1/27/09,effective 7/1/10.Statutory Authority:RCW 19.27.074,19.27.020,and <br /> chapters T-9-2-7 and 3 4.0 5 RCW.07-01-090,§51-51-0325,filed 12/19/06,effective 7/1/07.S ta t ut o ry A u t ho rity:RCW 19.27.031 and 19.27.074.04- <br /> 01-109,§_5_151-0 32 5,filed 12/17/03,effective 7/1/04.] <br /> Effective:2013 July 01 <br /> Updated:2017 February <br />
The URL can be used to link to this page
Your browser does not support the video tag.