My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1133 TTEREVE DR BETTY CARE 2019-11-19
>
Address Records
>
TTEREVE DR
>
1133
>
BETTY CARE
>
1133 TTEREVE DR BETTY CARE 2019-11-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2019 1:59:38 PM
Creation date
10/25/2017 9:18:19 AM
Metadata
Fields
Template:
Address Document
Street Name
TTEREVE DR
Street Number
1133
Tenant Name
BETTY CARE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` WAC 51-51-0325 <br /> Section R325—Adult family homes. <br /> SECTION R325 <br /> ADULT FAMILY HOMES <br /> R325.1 General.This section shall apply to all newly constructed adult family homes and all existing single family homes being <br /> converted to adult family homes. This section shall not apply to those adult family homes licensed by the state of Washington <br /> department of social and health services prior to July 1,2001. <br /> R325.2 Reserved. <br /> R325.3 Sleeping room classification.Each sleeping room in an adult family home shall be classified as: <br /> 1.Type S -Where the means of egress contains stairs,elevators or platform lifts. <br /> 2.Type NSI -Where one means of egress is at grade level or a ramp constructed in accordance w ith R325.9 is provided. <br /> 3.Type NS2 -Where tw o means of egress are at grade level or ramps constructed in accordance w ith R325.9 are provided. <br /> R325.4 Types of locking devices and door activation. All bedroom and bathroom doors shall be openable from the outside w hen <br /> locked. <br /> Every closet shall be readily openable from the inside. <br /> Operable parts of door handles, pulls, latches, locks and other devices installed in adult family homes shall be operable with one <br /> hand and shall not require tight grasping, pinching or twisting of the wrist.Pocket doors shall have graspable hardware available <br /> w hen in the closed or open position. <br /> The force required to activate operable parts shall be 5.0 pounds (22.2 N) maximum. Required exit doors shall have no additional <br /> locking devices. <br /> Required exit door hardw are shall unlock inside and outside mechanisms w hen exiting the building allowing reentry into the ad ult <br /> family home without the use of a key, tool or special knowledge. <br /> R325.5 Smoke and carbon monoxide alarm requirements.All adult family homes shall be equipped withsmoke and carbon <br /> monoxide alarms installed as required in Sections R314 and R315.1. Alarms shall be installed in such a manner so that the <br /> detection device warning is audible from all areas of the dwelling upon activation of a single alarm. <br /> R325.6 Escape windows and doors.Every sleeping room shall be provided w ith emergency escape and rescue w indows as <br /> required by Section R310. No alternatives to the sill height such as steps, raised platforms or other devices placed by the openings <br /> w ill be approved as meeting this requirement. <br /> R325.7 Fire apparatus access roads and water supplyfor fire protect ion.Adult family homes shall be served by fire apparatus <br /> access roads and water supplies meeting the requirements of the local jurisdiction. <br /> R325.8 Grab bar general requirements.Wherefacilities are designated for use by adult family home clients, grab bars forwater <br /> closets, bathtubs and shower stalls shall be installed according to this section. <br /> R325.8.1 Grab bar cross section.Grab bars w ith a circular cross section shall have an outside diameter of 1 1/4 inches minimum <br /> and 2 inches maximum. Grab bars w ith noncircular cross section shall have a cross section dimension of 2 inches maximum and a <br /> perimeter dimension of 4 inches minimum and 4 5/8 inches maximum. <br /> R325.8.2 Grab bar installation.Grab bars shall have a spacing of 1 1/2 inches between the wall and the bar. Projecting objects, <br /> control valves and bathtub or shcwerstall enclosure features above, below and at the ends of the grab bar shall have a clear space <br /> of 1 1/2 inches to the grab bar. <br /> EXCEPTION: Swing-up grab bars shall not be required to meet the 1 1/2 inch spacing requirement <br /> Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar, fastener, mounting device or <br /> supporting structural member. Grab bars shall not be supported directly by any residential grade'fiberglass bathing or showering <br /> unit. Acrylic bars found in bathing units shall be removed. <br /> Fixed position grab bars,w hen mounted, shall not rotate, spin or move and have a graspable surface finish. <br /> R325.8.3 Grab bars at water closets.Water closets shall have grab bars mounted on both sides. Grab bars can be a combination <br /> of fixed position and sw ing-up bars.Grab bars shall meet the requirements of R325.8. Grab bars shall mount betw een 33 inches <br /> and 36 inches above floor grade. Centerline distance betw een grab bars, regardless of type used, shall be betw een 25 inches <br /> Effective:2013 July 01 <br /> Updated:2017 February <br />
The URL can be used to link to this page
Your browser does not support the video tag.