Laserfiche WebLink
S I <br /> Subject: Proposed Aboud's Pita King LLC, 607 SE Everett Mall Way#9A, Everett <br /> April 7, 2015 <br /> Page 2 <br /> 10. This facility lacks a handwash sink behind the counter in the point of sales area. No open foods will be <br /> allowed in this area unless a handwash sink is installed. If a handwashsink is needed in this area it <br /> must be National Sanitation Foundation listed or equivalent. The location of the handwash sink must be <br /> approved prior to installation. <br /> 11. All foodservice equipment, both new and used, must be listed by the National Sanitation Foundation <br /> (NSF) or equivalent for its intended use. Used and new refrigeration must be capable of holding food at <br /> temperature of 41°F or below. <br /> 12. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed food <br /> service establishment. Used equipment must be clean, in proper operating condition, and in good repair. <br /> Used refrigeration must be capable of holding at a temperature of 41°F or below. <br /> 13. All food service equipment must be listed by the National Sanitation Foundation (NSF) or equivalent for <br /> its intended use. The Hobart mixer, Model#SN 11403508; the Rollfix sheeter (dough spreader), Model <br /> #SN 5200186228231; and the Middleby Marshall pizza oven, Model#PS 360, were not found in the <br /> current NSF or equivalent listings. This equipment must be replaced with NSF or equivalent listed <br /> equipment or documentation must be submitted which demonstrates NSF equivalency. Manufacturer <br /> names and model numbers for replacement equipment or equipment documentation must be submitted. <br /> Originally submitted manufacturer names and model numbers should be rechecked to assure the <br /> information submitted is accurate. Please note that subsidiary manufacturers are often not found in the <br /> NSF and equivalent listings. The manufacturer name should be verified and submit the parent company <br /> name if one is found. <br /> 14. No refrigeration equipment is proposed for this facility. No raw ingredients or finished product requiring <br /> refrigeration will be allowed unless refrigeration is in place. Any proposed refrigeration, both new and <br /> used, must be listed by the National Sanitation Foundation (NSF) or equivalent for its intended use. <br /> Used and new refrigeration must be capable of holding food at temperature of 41°F or below. <br /> 15. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and food <br /> preparation counters and tables. A 16-inch high backsplash of plastic laminate, fiberglass-reinforced <br /> plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall behind counter <br /> top equipment taller than 16 inches. Wall protection behind mop sinks must cover the entire splash <br /> zone. Plastic coated hardboard is not acceptable. <br /> 16. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be <br /> surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw cuts and <br /> the like in concrete floors in all areas, including customer seating areas, must be filled and sealed so as <br /> to provide a smooth and cleanable surface. <br /> 17. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and easily <br /> cleanable. <br /> 18. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type <br /> surfaces are not acceptable) <br /> 19. All light fixtures in food preparation and storage areas must be provided with covers and shatterproof <br /> bulbs. <br /> 20. Plumbing must meet state and local codes. <br /> • 21. It cannot be determined from the floor plan or information submitted whether or not a chemical <br /> dispensing system will be installed at the mop sink. Please note that the use of screw-on type 'wye' <br /> adaptors at the mop sink faucet for use with chemical dispensing systems is prohibited. Additionally, <br /> fY <br />