My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9600 HOLLY DR CHALLENGER ELEMENTARY SCHOOL 2017-12-20
>
Address Records
>
HOLLY DR
>
9600
>
CHALLENGER ELEMENTARY SCHOOL
>
9600 HOLLY DR CHALLENGER ELEMENTARY SCHOOL 2017-12-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2017 7:50:57 AM
Creation date
11/17/2017 12:05:46 PM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
9600
Tenant Name
CHALLENGER ELEMENTARY SCHOOL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Compatible Peripheral Devices TrueA/arm S stem O aeration <br /> The 4100ES is compatible with an extensive list of remote Addressable device communications include operation of <br /> peripheral devices including printers,CRT/keyboards(up to TrueAlarm smoke and temperature sensors.Smoke <br /> five total),and both conventional and addressable devices sensors transmit an output value based on their smoke <br /> including TrueAlarm analog sensors. chamber condition and the CPU maintains a current <br /> Addressable Device Control value,peak value,and an average value for each sensor. <br /> Status is determined by comparing the current sensor <br /> Overview.The 4100ES provides standard addressable value to its average value.Tracking this average value as <br /> device communications for IDNet compatible devices and a continuously shifting reference point filters out <br /> accepts optional modules for communications with environmental factors that cause shifts in sensitivity. <br /> MAPNET II compatible devices.Using a two wire Programmable sensitivity of each sensor can be <br /> communications circuit,individual devices such as manual selected at the control panel for different levels of smoke <br /> fire alarm stations,TrueAlarm sensors,conventional IDC obscuration(shown directly in percent)or for specific <br /> zones,and sprinkler waterflow switches can be interfaced to heat detection levels.To evaluate whether the sensitivity <br /> the addressable controller to communicate their identity and should be revised,the peak value is stored in memory and <br /> status. can be easily read and compared to the alarm threshold <br /> Addressability allows the location and condition of the directly in percent. <br /> connected device to be displayed on the operator interface <br /> LCD and on remote system annunciators.Additionally, CO sensor bases combine an electrolytic CO sensing <br /> control circuits(fans,dampers,etc.)may be individually module with a TrueAlarm analog sensor to provide a <br /> controlled and monitored with addressable devices. single multiple sensing assembly using one system <br /> address.The CO sensor can be enabled/disabled,used in <br /> Addressable Operation.Each addressable device on the LED/Switch modes and custom control,and can be made <br /> communication channel is continuously interrogated for public for communication across a fire alarm Network. <br /> status condition such as:normal,off-normal,alarm, (refer to data sheet S4098-0052 for details) <br /> supervisory,or trouble.Both Class B and Class A operation <br /> are available.Sophisticated poll and response TrueAlarm heat sensors can be selected for fixed <br /> communication techniques ensure supervision integrity and temperature detection,with or without rate-of-rise <br /> allow for"T-tapping"of the circuit for Class B operation. detection.Utility temperature sensing is also available, <br /> Devices with LEDs pulse the LED to indicate receipt of a typically to provide freeze warnings or alert to HVAC <br /> communications poll and can be turned on steady from the system problems.Readings can selected as either <br /> panel. Fahrenheit or Celsius. <br /> IDNet Channel Capacity.The CPU bay system power TrueSense Early Fire Detection.Multi-sensor <br /> supply(SPS)provides an IDNet signaling line circuit(SLC) 4098-9754 provides photoelectric and heat sensor data <br /> that supports up to 250 addressable monitor and control using a single 4100ES IDNet address.The panel evaluates <br /> points intermixed on the same pair of wires.Additional 250 smoke activity,heat activity,and their combination,to <br /> point IDNet circuit modules are available,refer to IDNet 2 provide TrueSense early detection.For more details on <br /> and IDNet 2+2 modules on page 7. this operation,refer to data sheet S4098-0024. <br /> IDNet, MAPNET II, IDNet 2,and IDNet 2+2 SLC Wiring Diagnostics and Default Device Type <br /> Common Specifications <br /> Maximum Distance 1 to 125 4000 ft(1219 m);50 ohms Sensor Status.TrueAlarm operation allows the control <br /> from Control Panel panel to automatically indicate when a sensor is almost <br /> per Device Load 126-250 2500 feet(762 m);35 ohms dirty,dirty,and excessively dirty.The NFPA 72 <br /> Terminals for 18 to 12 AWG requirement for a test of the sensitivity range of the <br /> Connections (0.82 mm2 to 3.31 mm2) <br /> sensors is fulfilled by the ability of TrueAlarm operation <br /> IDNet and MAPNET II Specifications to maintain the sensitivity level of each sensor.CO <br /> Preferred Shielded twisted pair(STP) Sensors track their 10 year active life status providing <br /> Wire Type indicators to assist with service planning.Indicators occur <br /> Acceptable* Unshielded twisted pair(UTP) at: 1 year,6 months,and when end of life is reached. <br /> IDNet and MAPNET II Wiring, <br /> Total Wire Length Allowed With Up to 10,000 ft(3 km);0.58 pF Modular TrueAlarm sensors use the same base and <br /> "T"Taps for Class B Wiring different sensor types(smoke or heat sensor)and can be <br /> IDNet 2 and IDNet 2+2 Wiring Specifications easily interchanged to meet specific location requirements. <br /> Shielded or unshielded,twisted This allows intentional sensor substitution during building <br /> Wire Type or untwisted wire* construction when conditions are temporarily dusty. <br /> Total Wire Length Allowed With Up to 12,500 ft(3.8 km); Instead of covering smoke sensors(causing them to be <br /> "T"Taps for Class B Wiring 0.60 pF disabled),heat sensors may be installed without <br /> Maximum Capacitance reprogramming the control panel.The control panel will <br /> Between IDNet 2 Channels 1 NF indicate an incorrect sensor type,but the heat sensor will <br /> IDNet 2 and IDNet 2+2 Module Compatibility:IDNet operate at a default sensitivity to provide heat detection <br /> communicating devices and TrueAlarm sensors including for building protection at that location. <br /> QuickConnect and QuickConnect2 sensors <br /> *Some applications may require shielded wiring.Review your <br /> system with your local Simplex product supplier. <br /> S4100-0031-30 12/2014 \<N.) <br />
The URL can be used to link to this page
Your browser does not support the video tag.