CPU Bay Module Details System Power Supply (Continued): <br /> • Three,3 A On-Board NACs,conventional reverse <br /> Master Controller and Motherboard: polarity operation;rated 3 A for Special Application <br /> • Mounts in Slot 4 of a two slot motherboard(Slots 3 and 4 appliances and 2 A for Regulated 24 DC power,with <br /> of the Master Controller Bay)and provides one Class B or electronic control and overcurrent protection;selectable <br /> Class A,RUI communications channel,available at Slot 4 as Class B or Class A,and for synchronized strobe or <br /> • RUI communications controls up to 31 devices per master SmartSync horn/strobe operation over two wires <br /> controller(on one or multiple RUI channels);devices • NACs can be selected as auxiliary power outputs <br /> include:MINIPLEX transponders,4603-9101 LCD derated to 2 A for continuous duty;the total auxiliary <br /> Annunciators,4602-9101 Status Command Units(SCU), power output per SPS is limited to 5 A <br /> 4602-9102 Remote Command Units(RCU),4602 Series • Battery Charger is dual rate,temperature compensated, <br /> LED Annunciator Panels,and 4100 Series 24 I/O and and charges up to 50 Ah sealed lead-acid batteries <br /> LED/Switch modules mounted in the battery compartment(33 Ah for single <br /> • Up to four RUI channels are supported;use up to three bay cabinets);also is UL listed for charging up to <br /> 4100-1291 RUI expansion modules as required 110 Ah batteries mounted in an external cabinet(see <br /> • Optional Service Modem 4100-6030 mounts onto the data sheet S2081-0012 for details) <br /> master controller board with its own on-board connections • Battery and Charger Monitoring includes battery ' <br /> • Slot 3 of the motherboard is pr.marily for the 4100-6078 charger status and low or depleted battery conditions; <br /> Network Interface Board with media modules,and status information provided to the master controller <br /> secondarily for the 4100-6038 Dual RS-232 Board includes analog values for:battery voltage,charger <br /> (4100-6038 is required for 2120 System connections) voltage and current,actual system voltage and current, <br /> and individual NAC currents <br /> System Power Supply: (see page 9 for more detail) • 2 A Auxiliary Power Output is selectable for detector <br /> • Rating is 9 A total with"Special Application"appliances; reset,door holder,or coded output operation <br /> 4 A total for"Regulated 24 DC"appliance power • Auxiliary Relay is selectable as N.O.or N.C.,rated 2 A <br /> • Outputs are power-limited,except for the battery charger @ 32 VDC,and is programmable as a trouble relay, <br /> • Provides system power,battery charging,auxiliary power, either normally energized or normally de-energized,or <br /> auxiliary relay,earth detection,on-board IDNet as an auxiliary control <br /> communications channel for 250 points,three on-board • Optional City Connect Module(4100-6031,with <br /> NACs,and provisions for either an optional City Connect disconnect switches,or 4100-6032,without disconnect <br /> Module or an optional Alarm Relay Module switches)can be selected for conventional dual circuit <br /> • IDNet SLC Output provides Class B or Class A city connections <br /> communications for up to 250 addressable devices(as • Optional Alarm Relay Module(4100-6033)provides <br /> described on page 4) three Form C relays that are used for Alarm,Trouble, <br /> and Supervisory,rated 2 A resistive @ 32 VDC <br /> Master Controller Selection Information <br /> 4100ES Master Controller and Expansion Bay Selection*(Canadian models have low battery cutout) <br /> Model Model Type and Listing Description Supv.** Alarm** <br /> 4100-9111 120 VAC Input UL 4100ES Master Controller Assembly with LCD and <br /> 4100-9112 English 120 VAC,Canadian ULC operator interface,9 A system power supply/battery 373 mA 470 mA <br /> 4100-9113 French charger(SPS),250 point IDNet interface,3 NACs, <br /> 4100-9211 220-240 VAC Input UL auxiliary relay,and external RUI communications interface <br /> 4100-9131 120 VAC Input UL 4100ES Master Controller Assembly,no display,no <br /> 4100-9132 English, 120 VAC,Canadian ULC operator interface,9 A system power supply/battery 363 mA 425 mA <br /> charger(SPS),250 point IDNet interface,3 NACs, <br /> 4100-9230 220-240 VAC Input UL auxiliary relay,and external RUI communications interface <br /> 4100-9121 Redundant Master Controller,two bay assembly;top bay contains LCD and operator interface, <br /> (not ULC CPU card assembly,and 4100ES,9 A system power supply/battery charger(SPS);second bay 718 mA 937 mA <br /> listed) contains CPU card in Slot 2,and LCD and operator interface; 120 VAC,60 Hz input; <br /> NOTE:RUI connections require use of 4100-1291 RUI expansion modules <br /> 4100ES Master Controller Upgrades for Existing 4100 Series Fire Alarm Control Panels* <br /> Model Panel Type Includes <br /> 4100-7150 1000 pt 4100(4100+) New Master Controller CPU card,4100ES door assembly with LCD and user interface,and <br /> Ethernet connection <br /> 4100-7152 512 pt 4100 Same as 4100-7150 plus a Universal Power Supply <br /> New Master Controller CPU card with Ethernet Connection Upgrade Kit(door assembly with <br /> 4100U or LCD and user interface are not included)for: <br /> 1000 pt 4100(4100+) 41000 with or without LCD and operator interface,or <br /> 4100-7158 previously upgraded 4100+without LCD and operator interface,or <br /> to 4100U An existing 4100(512 pt)or 4100+(1000 pt)panel that was previously upgraded to a 4100U <br /> Master Controller and Display <br /> *For InfoAlarm Command Center expanded content display products, refer to data sheet S4100-0045. (Continued on next page) <br /> **Note:Master Controller current does not subtract from 9 A output rating. <br /> S4100-0031-30 12/2014 <br />