My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2414 HOYT AVE 2017-11-27
>
Address Records
>
HOYT AVE
>
2414
>
2414 HOYT AVE 2017-11-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2017 2:47:56 PM
Creation date
11/17/2017 1:50:37 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2414
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CHAPTER 5 <br /> WATER CHEATERS <br /> 501.0 General. (1) Fuel-burning water heaters shall be permitted to be <br /> 501.1 Applicability. The regulations of this chapter shall installed in a closet located in the bedroom or bathroom <br /> govern the construction, location, and installation of fuel- provided the closet is equipped with a listed, gasketed <br /> burning and other types of water heaters heating potable door assembly and a listed self-closing device.The self- <br /> water, together with chimneys, vents, and their connectors. closing door assembly shall meet the requirements of <br /> The minimum capacity for storage water heaters shall be in Section 504.1.1. The door assembly shall be installed <br /> accordance with the first hour rating listed in Table 501.1(1). with a threshold and bottom door seal and shall meet the <br /> No water heater shall be hereinafter installed that does not requirements of Section 504.1.2.Combustion air for such <br /> comply with the manufacturer's installation instructions and installations shall be obtained from the outdoors in accor- <br /> the type and model of each size thereof approved by the dance with Section 506.4. The closet shall be for the <br /> Authority Having Jurisdiction.A list of accepted water heater exclusive use of the water heater. <br /> appliance standards are referenced in Table 501.1(2). Listed (2) Water heater shall be of the direct vent type. [NFPA <br /> appliances shall be installed in accordance with the manu- 54:10.28.1(2)] <br /> facturer's installation instructions. Unlisted water heaters 504.1.1 Self-Closing Doors. Self-closing doors shall <br /> shall be permitted in accordance with Section 504.3.2. swing easily and freely,and shall be equipped with a self- <br /> closing device to cause the door to close and latch each <br /> 502.0 Permits. time it is opened.The closing mechanism shall not have <br /> a hold-open feature. <br /> 502.1 General. It shall be unlawful for a person to install, 504.1.2 Gasketing. Gasketing on gasketed doors or <br /> remove, or replace or cause to be installed, removed, or frames shall be furnished in accordance with the pub- <br /> replaced a water heater without first obtaining a permit from lished listings of the door, frame, or gasketing material <br /> the Authority Having Jurisdiction to do so. manufacturer. <br /> Exception: Where acceptable to the Authority Having <br /> 503.0 Inspection. Jurisdiction, gasketing of non-combustible or limited- <br /> 503.1 Inspection of Chimneys or Vents. This inspec- combustible material shall be permitted to be applied to <br /> tion shall be made after chimneys, vents, or parts thereof, the frame,provided closing and latching of the door are <br /> authorized by the permit,have been installed and before such not inhibited. <br /> vent or part thereof has been covered or concealed. 504.2 Vent. Water heaters of other than the direct-vent type <br /> 503.2 Final Water Heater Inspection. This inspection shall be located as close as practical to the chimney or gas vent <br /> shall be made after work authorized by the permit has been 504.3 Clearance. The clearance requirements for water <br /> installed.The Authority Having Jurisdiction will make such heaters shall comply with Section 504.3.1 or Section 504.3.2. <br /> inspection as deemed necessary to be assured that the work 504.3.1 Listed Water Heaters. The clearances shall <br /> has been installed in accordance with the intent of this code. not be such as to interfere with combustion air,draft hood <br /> No appliance or part thereof shall be covered or concealed clearance and relief,and accessibility for servicing.Listed <br /> until the same has been inspected and approved by the water heaters shall be installed in accordance with their <br /> Authority Having Jurisdiction. listings and the manufacturer's installation instructions. <br /> 504.3.2 Unlisted Water Heaters. Unlisted water <br /> 504.0 Water Heater Requirements. heaters shall be installed with a clearance of 12 inches <br /> 504.1 Location.Water heater installations in bedrooms and (305 mm)on all sides and rear.Combustible floors under <br /> bathrooms shall be in accordance with one of the following unlisted water heaters shall be protected in an approved <br /> [NFPA 54:10.28.1]: manner. [NFPA 54:10.28.2.2] <br /> TABLE 501.1(1) <br /> FIRST HOUR RATING1 <br /> Number of Bathrooms 1 to 1.5 2 to 2.5 3 to 3.5 <br /> Number of Bedrooms 1 2 3 2 3 4 5 3 4 5 6 <br /> First Hour Rating,2 Gallons 42 54 54 54 67 67 80 67 80 80 80 <br /> For SI units:1 gallon=3.785 L <br /> Notes: <br /> 1 The first hour rating is found on the"Energy Guide"label. <br /> 2 Solar water heaters shall be sized to meet the appropriate first hour rating as shown in the table. <br /> 2015 UNIFORM PLUMBING CODE <br />
The URL can be used to link to this page
Your browser does not support the video tag.