My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
GeoEngineers Inc 11/6/2017 Amendment 1
>
Contracts
>
6 Years Then Destroy
>
2020
>
GeoEngineers Inc 11/6/2017 Amendment 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2017 11:14:42 AM
Creation date
12/7/2017 11:14:34 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
GeoEngineers Inc
Approval Date
11/6/2017
End Date
12/31/2020
Department
Facilities
Department Project Manager
Mike Palacios
Subject / Project Title
Environmental Consulting Smith Street Mill
Amendment/Change Order
Amendment
Amendment/Change Order Number
1
Total Compensation
$171,000.00
Contract Type
Agreement
Contract Subtype
Professional Services
Retention Period
6 Years Then Destroy
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 3 of 5 <br /> 9. Evaluate soil and groundwater chemical analytical results relative to MTCA Method A cleanup levels for <br /> unrestricted land use. Interpret the field and chemical analytical data relative to the study objectives. <br /> 10. Investigative derived wastes (IDW) will be drummed, labeled and placed at a location designated by the <br /> City pending disposal at future time. Costs for disposal of drums is not included in this scope of work and <br /> we assume drum disposal will occur during the Site cleanup. <br /> As noted above we will initiate an underground utility location clearance check in accordance with State law. <br /> We will also hire a private utility locating firm to locate utilities within the site, as the one-call system does not <br /> normally locate utilities on private property. Based on communications with the former facility operator during <br /> GeoEngineers' Phase II ESA, we anticipate that a buried power line may be present in the area between the <br /> former mill office and the former location of the truck scales.The power line will need to be marked before we <br /> can undertake additional explorations at the site. We request the City's assistance in locating this utility. We <br /> will use appropriate diligence when locating our borings to avoid utilities. However, we assume no liability if <br /> damage to utilities occurs from our explorations if utility locations are not shown on drawings or not located. <br /> Task 3:Remedial Investigation and Feasibility Study(RI/FS)Report <br /> 1. Summarize the results of the remedial investigations in a comprehensive RI report following Ecology's RI <br /> checklist requirements,as appropriate for this Site. <br /> 2. Prepare a FS report based on the RI results and following Ecology's FS checklist requirements, as <br /> appropriate for this Site.We do not anticipate needing to complete a MICA disproportionate cost analysis <br /> (DCA)given that the proposed redevelopment of the Property will involve earthwork and capping, and we <br /> anticipate that excavation and capping will be components of the preferred cleanup alternative in <br /> accordance with MICA requirements. <br /> 3. The RI and FS will be combined into an RI/FS report. A copy of the draft RI/FS report will be provided to <br /> the City for review and comment. GeoEngineers will incorporate client comments and revise the draft <br /> RI/FS prior to submittal to Ecology along with the draft CAP. <br /> 4. The RI/FS report would be finalized after incorporating comments from Ecology, as appropriate. We <br /> assume a disproportionate cost analysis (DCA) will not be required by Ecology as part of the RI/FS; if <br /> Ecology requires a DCA,we will submit a contract amendment at a future time. <br /> Task 4:Cleanup Action Plan(CAP) <br /> 1. Prepare a draft Cleanup Action Plan(CAP)following Ecology's checklist,as appropriate for this Site based <br /> on the RI/FS findings.The draft CAP will present the preferred cleanup alternative. <br /> 2. A copy of the draft CAP will be provided to the City for review and comment.GeoEngineers will incorporate <br /> client comments and revise the draft CAP prior to submittal to Ecology. <br /> 3. The CAP report would be finalized after incorporating comments from Ecology, as appropriate. <br /> Task 5:VCP Meetings/Communication and Project Coordination <br /> 1. Communicate and meet with Ecology to discuss VCP submittals and Ecology opinion letters. <br /> 2. Provide supporting environmental consulting or input to the City related to the RI, FS and CAP and <br /> proposed cleanup, on an as-requested basis. <br /> 3. Perform routine project management, budget tracking, and invoicing. <br /> For the routine project management subtasks,we assume 30 hours of professional labor. <br /> GeoEngineers,Inc. <br /> File No.0661-108-02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.