My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2625 HOYT AVE 2019-01-11
>
Address Records
>
HOYT AVE
>
2625
>
2625 HOYT AVE 2019-01-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2019 1:32:10 PM
Creation date
1/9/2018 9:39:36 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2625
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i � � � <br /> : 2. Vertical fenestration alternate per Section existing structure,or proximity to <br /> : C402.4.11 for the area adjacent to the new adjacent air intakes/exhausts make full <br /> : vertical fenestration added. compliance impractical.Alternate designs shall <br /> : 3. Component performance option with target area provide alternate energy savings strategies <br /> : adjustment per Section C402.1.5 or the total including,but not limited to,Demand Control <br /> : building perfonnance option in Section C407 Ventilation or increased mechanical cooling or <br /> : for the whole building. heating efficiency above that required by Tables <br /> C4032.3(1)through C403.2.3(10). <br /> C503.3.2.1 Application to replacement 2. Qualifying small equipment: This exception *" <br /> fenestration products. �Vhere some or all of an shall not be used for unitary cooling ec�uipinent <br /> existing,fenest�•ation unit is replaced with a new installed outdoors or in a mechanical room <br /> .fenesli•ation product,including sash and glazing,the adjaccnt to the outdoors.This exception is <br /> repl acement,fenestration tuiit shall meet the allowed to be iised for other cooling units and <br /> applicable reqtiirements for U-factor and SHGC in split systems seiving one zone�vith a total <br /> Table C402.4. cooling capacity rated in accordance with <br /> �xception: An area-weighted average of the Section C403.2.3 of less than 33,000 Btu/h <br /> U-factor of replacement fenestration products (��ereafter referred to as qualifying small <br /> being installed in the building for each fenestration systems)provided that these are high-efficiency <br /> product category listed in Table C402.4 shall be cooling equipment with SE�R and EER values <br /> permitted to satisfy the U-factor requirements for more than ]5 percent higher than minimum <br /> each fenestration product category listed in Table efficiencies listed in Tables C403.2.3(1)through <br /> C402.4.Individual fenestration products from 3 m the a ro riate size cate or usin the <br /> different product categories listed in Table C402.4 � �' pp p g y' g <br /> shall not be combined in calculating the same test proced�ires.Equipment shall be listed <br /> area-weighted average U-factor. in the appropriate certification program to <br /> qualify for this exception.The total capacity of <br /> C503.3.3 Skylight area.The addition of skylights that all c�ualifying small equipment without <br /> results in a total building skylight area less than or equal economizers shall not exceed 72,000 Btu/h per <br /> to that specified in Section C402.41 shall comply with building,or 5 percent of its air economizer <br /> Section C402.4.�Iltey�ations that result in a total capacity,�hichever is�reater.That portion of <br /> . building skylight area greater than that specified in the equipment serving Group R occupancies is <br /> : Section C402.4.1 shall comply with the component not included in determining the total capacity of <br /> : performance option with target area adjustment per all units without economizers in a building. <br /> : Section C402.1.5 or the total building performance Redundant units are not cotmted in the capacity <br /> : option in Section C407 for the whole building. limitations.This exception shall not be used for <br /> ' tlie sliell-and-core permit or for the initial tenant <br /> ** � C503.4 Mechanic�l systems.Those parts of systems �mprovement or for Total Building Performance. ** <br /> . which are altered or replaced shall comply with Section 3. Chilled water terminal units connected to <br /> : C403.Additions or alterations shall not be made to an <br /> : existing mechanical system that will cause the existing systems with chilled water generation equipment <br /> : mechanical system to become out of compliance. with]PLV values more than 25 percent higher <br /> than minimum part load efficiencies listed in <br /> Exception:�xisting mechanical systems which are Table C403.2.3(7),in the appropriate size <br /> altered or where parts of tlie system are replaced are not category,using the same test procedures. <br /> required to be modified to comply with Section C403.6 Equipment shall be listed in the appropriate <br /> as long as mechanical cooling is not added to the certification program to qualify for this <br /> system. exception.The total capacity of all systems <br /> All new systems in existing buildings,including without economizers shall not exceed 480,000 <br /> packaged unitary equipment and packaged split systems, Btu/h per building,or 20 percent of its air <br /> shall comply with Section C403. economizer capacity,whichever is greater.That <br /> Where mechanical cooling is added to a space that was portion of the equipment serving Group R <br /> not previously cooled,the mechanical system shall occupancy is not incl�ded in determining the <br /> comply with either Section C403.6 or C403.3. , total capacity of all units without economizers in <br /> Exceptions: a building.T$is exception shall not be used for <br /> � ]. Alternate designs that are not in full compliance the initial permit(this includes any initial permit <br /> with this code may be approved when the code for the space including,but not limited to,the <br /> official determines that existing building shell-and-core permit,built-to-suit permit,and <br /> constraints including,but not limited to, tenant improvement permit)or for Total <br /> available mechanical space,limitations of the Building Performance Method. <br /> �� <br /> 2015 Washington State Energy Code CE-121 <br /> �� y) <br />
The URL can be used to link to this page
Your browser does not support the video tag.