My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6611 ASSOCIATED BLVD AMAZON 2021-02-17
>
Address Records
>
ASSOCIATED BLVD
>
6611
>
AMAZON
>
6611 ASSOCIATED BLVD AMAZON 2021-02-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2021 8:44:08 AM
Creation date
1/11/2018 2:04:30 PM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6611
Tenant Name
AMAZON
Notes
CORPORATE LLC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n � � Plan Check Comment Responses '� <br /> Robison Ern�ineering, Inc. '�, � �-� <br /> 1940140 Ave.W.Suite 302 <br /> Lynnwood,Washington 98036 <br /> 206-364-3342 <br /> RECEIPT DATE: 05/01/2017 REVIEW DATE: 05/03/2017 <br /> PROJECT: Amazon Everett Distribution Center REI PROJECT NUMBER: 621-058 <br /> ARCHITECT: Dustin Thorlakson, Freiheit&Ho Architects,Inc REVIEWED BY: John Harrington <br /> SUBJECT: City of Everett Public Works—Correcltions for Building Plan Review Permit No. 61703-007 <br /> The purpose of this document is to describe revisions made to plans in response to redlined plan corrections.Corrections are <br /> noted in bold. <br /> ENERGY <br /> 1. Alterations which replace more than 50% of the luminaires have to comply with lighting controls, per <br /> WSEC C503.6. <br /> Warehouse space not planned for use as storage, but as a sort facility. Lighting controls for <br /> warehouse space by way of time-clock with override to match space use (like an open office area). <br /> Plans updated to reflect lighting controls. <br /> a. Please include both the interior and the exterior lighting in the lighting summary and analysis using <br /> the LIGHT-SUM form, per WSEC table C405.5.2 (1). This WSEC form should be submitted as part of <br /> the tenant improvement. <br /> Updated Interior Lighting WSEC compliance forms included in Electrical set. Exterior Lighting is not <br /> included in the scope of this project. Exterior Lighting WSEC compliance forms not required. Plans <br /> updated to reflect updated forms. <br /> b. Please include actual code section language on the drawings for interior and exterior lighting <br /> controls, sensors, and all other methods of compliance covered in electrical power and lighting <br /> systems per WSEC section C405. <br /> WSEC notes included in Electrical Set. Plans updated to include code language for controls, sensors, <br /> and all other methods of compliance per WSEC�C405. <br /> 2. Please identify if the S-2 occupancy is semi-heated, per WSEC section C402.1.1.1, or low energy path, <br /> which requires documentation on the plans for the intent for use and heating of the space per <br /> one of the four options summarized in WSEC section C402.1.1. <br /> S-2 is NOT semi-heated. It is treated as fully conditioned. No changes made to the plans. <br /> 3. A change to the space conditioning of the warehouse to semi-heated or to non-conditioned <br /> will require replacement and modification of existing structure and fenestration of the office and <br /> mezzanine structure, per IEBC C503.2. <br /> a. For the change of warehouse occupancy to S-2 vehicular use, please indicate the prescriptive <br /> method of building envelope compliance for the offices first floor and mezzanine, the existing <br /> building within the building, to include detailed R-Values of existing or modified interior and <br /> exterior walls, roof-ceiling cavities, man-doors and garage doors, per WSEC section C402.1. <br />